Back to Authors

Vrtiska, Terri J.

Mayo Clinic

Mayo Clinic

Citations 20

The feasibility of low iodine dynamic CT angiography with test bolus for evaluation of lower extremity peripheral artery disease
Inoue, Akitoshi , Vrtiska, Terri J., Lee, Yong S. , Vasconcelos, Rogerio N., Weber, Nikkole M. , Halaweish, Ahmed F., Duba, Irene , Williamson, Eric E. , Fletcher, Joel G , Inoue, Akitoshi , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G.

Vascular | January 18, 2021 | Volume: 29 | Issue: 6 | Pages: 927-937

10.1177/1708538120986304 Get It

Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively ( p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus ( p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) ( p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients ( p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.
Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose
Gutjahr, Ralf , Lee, Yong S. , Halaweish, Ahmed F., Suresh, Vighnesh , Weber, Nikkole M. , Vrtiska, Terri J., Williamson, Eric E. , Schmidt, Bernhard , Fletcher, Joel G. , McCollough, Cynthia H.

Journal of Computer Assisted Tomography | July 3, 2019 | Volume: 43 | Issue: 4 | Pages: 612-618

10.1097/rct.0000000000000874 Get It

Objective The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. Methods The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. Results The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. Conclusion The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.
Symptomatic and Radiographic Manifestations of Kidney Stone Recurrence and Their Prediction by Risk Factors: A Prospective Cohort Study
D’Costa, Matthew R. , Haley, William E. , Mara, Kristin C. , Vrtiska, Terri J., Pais, Vernon M., Jacobsen, Steven J. , Rule, Andrew D. , Rule, Andrew D , Haley, William E , D'Costa, Matthew , Mara, Kristin C , Enders, Felicity , McCollough, Cynthia H. , Lieske, John C.

Journal of the American Society of Nephrology | June 7, 2019 | Volume: 30 | Issue: 7 | Pages: 1251-1260

10.1681/asn.2018121241 Get It

Significance Statement Kidney stone recurrence can manifest with symptoms from stone passage or with asymptomatic changes in kidney stone burden revealed by radiography. In a multicenter, prospective cohort study, the authors demonstrate that substantially more asymptomatic and self-managed symptomatic kidney stone recurrence occur in stone formers than has been appreciated, as many studies consider only symptomatic recurrence that results in clinical care. Among first-time symptomatic stone formers, 54% had an asymptomatic kidney stone; half of those with such a stone passed it within 5 years (but only half who did so experienced symptoms). The findings also show that when a more comprehensive definition of recurrence that includes all symptomatic and radiological manifestations is used, risk factors better predict kidney stone recurrence, thus supporting a comprehensive assessment of recurrence in clinical trials. Background Meaningful interpretation of changes in radiographic kidney stone burden requires understanding how radiographic recurrence relates to symptomatic recurrence and how established risk factors predict these different manifestations of recurrence. Methods We recruited first-time symptomatic stone formers from the general community in Minnesota and Florida. Baseline and 5-year follow-up study visits included computed tomography scans, surveys, and medical record review. We noted symptomatic recurrence detected by clinical care (through chart review) or self-report, and radiographic recurrence of any new stone, stone growth, or stone passage (comparing baseline and follow-up scans). To assess the prediction of different manifestations of recurrence, we used the Recurrence of Kidney Stone (ROKS) score, which sums multiple baseline risk factors. Results Among 175 stone formers, 19% had symptomatic recurrence detected by clinical care and 25% detected by self-report; radiographic recurrence manifested as a new stone in 35%, stone growth in 24%, and stone passage in 27%. Among those with a baseline asymptomatic stone (54%), at 5 years, 51% had radiographic evidence of stone passage (accompanied by symptoms in only 52%). Imaging evidence of a new stone or stone passage more strongly associated with symptomatic recurrence detected by clinical care than by self-report. The ROKS score weakly predicted one manifestation—symptomatic recurrence resulting in clinical care ( c -statistic, 0.63; 95% confidence interval, 0.52 to 0.73)—but strongly predicted any manifestation of symptomatic or radiographic recurrence (5-year rate, 67%; c -statistic, 0.79; 95% confidence interval, 0.72 to 0.86). Conclusions Recurrence after the first stone episode is both more common and more predictable when all manifestations of recurrence (symptomatic and radiographic) are considered.
Detection and Characterization of Renal Stones by Using Photon-Counting–based CT
Marcus, Roy , Fletcher, Joel G. , Ferrero, Andrea , Leng, Shuai , Halaweish, Ahmed F., Gutjahr, Ralf , Vrtiska, Terri J., Wells, Mike L., McCollough, Cynthia H. , Marcus, Roy P, Enders, Felicity T, McCollough, Cynthia H , Fletcher, Joel G , Leng, Shuai , Enders, Felicity

Radiology | August 7, 2018 | Volume: 289 | Issue: 2 | Pages: 436-442

10.1148/radiol.2018180126 Get It

A multi-reader in vitro study using porcine kidneys to determine the impact of integrated circuit detectors and iterative reconstruction on the detection accuracy, size measurement, and radiation dose for small (
Wells, Michael , Froemming, Adam T. , Vrtiska, Terri J., Hartman, Robert P. , Holmes, David R. , Carter, Rickey E. , Bartley, Adam C. , Wells, Michael L, Kawashima, Akira , Kim, Bohyun , Leng, Shuai , McCollough, Cynthia H. , Fletcher, Joel G. , Carter, Rickey E

Acta Radiologica | March 6, 2017 | Volume: 58 | Issue: 8 | Pages: 1012-1019

10.1177/0284185116682382 Get It

Background Detection of small renal calculi has benefitted from recent advances in computed tomography (CT) scanner design. Information regarding observer performance when using state-of-the-art CT scanners for this application is needed. Purpose To assess observer performance and the impact of radiation dose for detection and size measurement of <4 mm renal stones using CT with integrated circuit detectors and iterative reconstruction. Material and Methods Twenty-nine <4 mm calcium oxalate stones were randomly placed in 20 porcine kidneys in an anthropomorphic phantom. Four radiologists used a workstation to record each calculus detection and size. JAFROC Figure of Merit (FOM), sensitivity, false positive detections, and calculus size were calculated. Results Mean calculus size was 2.2 ± 0.7 mm. The CTDI vol values corresponding to the automatic exposure control settings of 160, 80, 40, 25, and 10 Quality Reference mAs (QRM) were 15.2, 7.9, 4.2, 2.7, and 1.3 mGy, respectively. JAFROC FOM was ≥ 0.97 at ≥ 80 QRM, ≥ 0.89 at ≥ 25 QRM, and was inferior to routine dose (160 QRM) at 10 QRM (0.72, P < 0.05). Per-calculus sensitivity remained ≥ 85% for every reader at ≥ 25 QRM. Mean total false positive detections per reader were ≤ 3 at ≥ 80 QRM, but increased substantially for two readers ( ≥ 12) at ≤ 40 QRM. Measured calculus size significantly decreased at ≤ 25 QRM ( P ≤ 0.01). Conclusion Using low dose renal CT with iterative reconstruction and ≥ 25 QRM results in high sensitivity, but false positive detections increase for some readers at very low dose levels (≤ 40 QRM). At very low doses with iterative reconstruction, measured calculus size will artifactually decrease.
Reducing Iodine Contrast Volume in CT Angiography of the Abdominal Aorta Using Integrated Tube Potential Selection and Weight-Based Method Without Compromising Image Quality
Vasconcelos, Rogerio N., Vrtiska, Terri J., Foley, Thomas A. , Macedo, Thanila A. , Cardona, Juan C. Montoya, Williamson, Eric E. , Vasconcelos, Rogerio, McCollough, Cynthia H. , Fletcher, Joel G.

American Journal of Roentgenology | February 22, 2017 | Volume: 208 | Issue: 3 | Pages: 552-563

10.2214/ajr.16.16613 Get It

Surgical treatment of varicose veins and venous malformations in Klippel–Trenaunay syndrome
Malgor, Rafael D. , Gloviczki, Péter , Fahrni, Jennifer , Kalra, Manju , Duncan, Audra A. , Vrtiska, Terri J., Driscoll, David, Vrtiska, Terri, Oderich, Gustavo S. , Gloviczki, Péter

Phlebology: The Journal of Venous Disease | March 18, 2015 | Volume: 31 | Issue: 3 | Pages: 209-215

10.1177/0268355515577322 Get It

Background Klippel–Trenaunay syndrome (KTS) is a mixed mesenchymal malformation characterised by varicose veins, venous and capillary malformations, and hypertrophy of soft tissue and bone. The purpose of this study was to evaluate the surgical outcomes in KTS patients to provide standards for comparison with endovenous therapy. Methods The clinical data of consecutive patient with KTS who underwent open venous surgical treatment between January 1987 and December 2008 were reviewed. Demographics, clinical presentation, operative data, and clinical outcomes were recorded. Follow-up information was obtained from the medical records, mailed questionnaires and phone calls. Descriptive statistics, the Kaplan–Meier method and Log-rank statistics were used where appropriate. Results Twenty-seven females and 22 males, (mean age 26.5 years, range 7.7–55.8) were included in this study. All had varicose veins, 36 (73%) had limb hypertrophy, and 33 (67%) had capillary malformations, with two of three clinical features present in all. The most frequent symptom was pain (N = 43, 88%). Forty-nine patients underwent operations on 53 limbs. Stripping of the GSV, small and accessory saphenous and lateral embryonic veins was performed in 17 (32%), 10 (19%), 9 (17%), and 15 (28%) limbs, respectively. Two patients developed deep vein thrombosis, one had pulmonary embolism (PE), and one patient had peroneal nerve palsy. Freedom from disabling pain at 1, 3 and 5 years was 95%, 77% and 59%, respectively, and freedom from secondary procedures was 78% at 3 years, and 74% at 5 years. At the last follow-up visit, the venous clinical severity score had decreased from 9.48 ± 3.27 to 6.07 ± 3.20 (P < 0.001). Conclusions In selected symptomatic patients with KT syndrome, open surgical treatment is safe and durable. Three-fourths of the patients remain free of disabling pain at five years, but secondary procedures are required in one-fourth of the patients. These data can serve as standards for comparison of endovenous therapy for KT syndrome.
Feasibility of Discriminating Uric Acid From Non–Uric Acid Renal Stones Using Consecutive Spatially Registered Low- and High-Energy Scans Obtained on a Conventional CT Scanner
Shiung, Maria, Qu, Mingliang , Vrtiska, Terri J., Grant, Katharine L., Krauß, Bernhard , Schmidt, Bernhard , Leng, Shuai , Ai, Songtao , Lieske, John C. , McCollough, Cynthia H.

American Journal of Roentgenology | December 24, 2014 | Volume: 204 | Issue: 1 | Pages: 92-97

10.2214/ajr.13.11911 Get It

Coronary Artery Tortuosity in Spontaneous Coronary Artery Dissection
Eleid, Mackram F. , Best, Patricia J.M. , Vrtiska, Terri J., Prasad, Megha , Rihal, Charanjit S. , Gulati, Rajiv , Guddeti, Raviteja R, Tweet, Marysia S. , Best, Patricia J., Guddeti, Raviteja , Lerman, Amir , Singh, Mandeep , Rihal, Charanjit S. , Hayes, Sharonne N.

Circulation: Cardiovascular Interventions | August 20, 2014 | Volume: 7 | Issue: 5 | Pages: 656-662

10.1161/circinterventions.114.001676 Get It

Background— Spontaneous coronary artery dissection (SCAD) is an increasingly recognized nonatherosclerotic cause of acute coronary syndrome. The angiographic characteristics of SCAD are largely undetermined. The goal of this study was to determine the prevalence of coronary tortuosity in SCAD and whether it may be implicated in the disease. Methods and Results— Patients with confirmed SCAD (n=246; 45.3±8.9 years; 96% women) and 313 control patients without SCAD or coronary artery disease who underwent coronary angiography were included in this case–control study. Angiograms were reviewed for coronary tortuosity and assigned a tortuosity score. Tortuosity was common in patients presenting with their first SCAD event (78% versus 17% in controls; P <0.0001; tortuosity score, 4.41±1.73 versus 2.33±1.49 in controls; P <0.0001) despite a low prevalence of hypertension (34%). Recurrent SCAD (n=40) occurred within segments of tortuosity in 80% of cases. Severe tortuosity (≥2 consecutive curvatures ≥180°) was associated with a higher risk of recurrent SCAD (hazard ratio, 3.29; 95% confidence interval, 0.99–8.29; P =0.05). Tortuosity score >5 was associated with a trend toward higher risk of recurrent SCAD ( P =0.16). Prespecified angiographic markers of tortuosity including corkscrew appearance and multivessel symmetrical tortuosity were associated with extracoronary vasculopathy including fibromuscular dysplasia ( P <0.05 for both). Conclusions— Coronary artery tortuosity is highly prevalent in the SCAD population and is associated with recurrent SCAD. Recurrent SCAD most often occurs within segments of tortuosity. Angiographic features of SCAD are associated with extracoronary vasculopathy, including fibromuscular dysplasia. These findings suggest that coronary tortuosity may serve as a marker or potential mechanism for SCAD.
Automatic Selection of Tube Potential for Radiation Dose Reduction in Vascular and Contrast-Enhanced Abdominopelvic CT
Yu, Lifeng , Grant, Katharine L., Carter, Rickey E. , Hough, David M., Barlow, John M. , Vrtiska, Terri J., Williamson, Eric E. , Young, Phillip M. , Goss, Brian C., Shiung, Maria, Raupach, Ranier, Schmidt, Bernhard , Flohr, Thomas , Yu, Lifeng , Fletcher, Joel G. , Leng, Shuai , McCollough, Cynthia H. , Carter, Rickey E

American Journal of Roentgenology | July 24, 2013 | Volume: 201 | Issue: 2 | Pages: W297-W306

10.2214/ajr.12.9610 Get It