Abstract Objectives Determine differences in quantitative stenosis severity measurements for ultra-high-resolution (UHR) photon-counting detector (PCD) coronary CT angiography (cCTA) relative to energy-integrating detector (EID) cCTA in a large patient cohort. Methods Adult participants seen between November 2022 and March 2023 underwent a clinical dual-source EID-CT cCTA and a research dual-source PCD-CT cCTA on the same day. Percent diameter stenosis (PDS) was measured, and stenosis severity was assigned based on the PDS of the most severe lesion per patient to determine a coronary artery disease reporting and data system (CAD-RADS) score. Agreement between EID-CT and PCD-CT for PDS and CAD-RADS was determined. Results A total of 112 participants were enrolled, yielding 82 subjects with at least 1 stenosis at PCD-CT (mean age, 68.0 ± 10.8 years; 69.5% [57/82] males). A total of 177 paired stenoses were quantified. The percent decrease in mean PDS from PCD-CT (24.3%) to EID-CT (29.4%) was 17.3% (median difference in PDS: −5.0%, 95% CI: −5.7% to −4.0%). The assigned CAD-RADS score changed in 31/82 subjects. In 11/31 subjects, the most severe stenosis was missed at EID-CT due to partial volume averaging of a small calcification, yet PCD clearly identified stenosis at those locations. In 20/31 subjects, the CAD-RADS score decreased at PCD-CT due to the decreased calcium blooming resulting from the improved spatial resolution. Conclusions UHR PCD cCTA decreases quantitative measures of stenosis severity when a stenosis is identified at EID, leading to decreases in CAD-RADS assignments. Advances in knowledge With its improved spatial resolution, PCD-CT identifies stenoses missed on EID-CT.
The Emerging Role of Computed Tomography Coronary Angiography in the Left Main Stem Percutaneous Coronary Intervention
Recent advancements in computed tomography have significantly transformed the clinical application of this technique in diagnosing and managing coronary artery disease (CAD). Computed tomography coronary angiography (CTCA) has emerged as a leading non-invasive imaging modality, often serving as the first-line investigation to exclude obstructive CAD in patients with chronic coronary syndrome. Beyond its utility in diagnosing CAD, CTCA has become instrumental in procedural planning for percutaneous coronary intervention (PCI), particularly in complex cases such as left main stem (LMS) interventions, where peri-procedural risks are elevated. This review highlights the evolving role of CTCA in LMS PCI, underscoring its clinical utility in improving procedural precision and, subsequently, patient outcomes. Recent technological advancements, including detailed multiplanar and three-dimensional (3D) reconstructions, CT-derived fractional flow reserve (CTFFR), and the integration of artificial intelligence (AI) algorithms, have expanded the capabilities of CTCA. These innovations allow for comprehensive anatomical and functional assessments, enabling precise plaque morphology, lesion complexity, and bifurcation anatomy evaluations alongside PCI simulations. By offering detailed insights into coronary vasculature and lesion characteristics, CTCA provides critical information for optimising LMS PCI strategies. This review explores the current applications and future potential of CTCA in guiding LMS PCI, highlighting its role in improving procedural planning, risk assessment, and overall management of this challenging patient population.
Staging of breast cancer in the breast and regional lymph nodes using contrast-enhanced photon-counting detector CT: accuracy and potential impact on patient management
Abstract Objectives To describe the feasibility and evaluate the performance of multiphasic photon-counting detector (PCD) CT for detecting breast cancer and nodal metastases with correlative dynamic breast MRI and digital mammography as the reference standard. Methods Adult females with biopsy-proven breast cancer undergoing staging breast MRI were prospectively recruited to undergo a multiphasic PCD-CT using a 3-phase protocol: a non-contrast ultra-high-resolution (UHR) scan and 2 intravenous contrast-enhanced scans with 50 and 180 s delay. Three breast radiologists compared CT characteristics of the index malignancy, regional lymphadenopathy, and extramammary findings to MRI. Results Thirteen patients underwent both an MRI and PCD-CT (mean age: 53 years, range: 36-75 years). Eleven of thirteen cases demonstrated suspicious mass or non-mass enhancement on PCD-CT when compared to MRI. All cases with metastatic lymphadenopathy (3/3 cases) demonstrated early avid enhancement similar to the index malignancy. All cases with multifocal or multicentric disease on MRI were also identified on PCD-CT (3/3 cases), including a 4 mm suspicious satellite lesion. Four of five patients with residual suspicious post-biopsy calcifications on mammograms were detected on the UHR PCD-CT scan. Owing to increased field-of-view at PCD-CT, a 5 mm thoracic vertebral metastasis was identified at PCD-CT and not with the breast MRI. Conclusions A 3-phase PCD-CT scan protocol shows initial promising results in characterizing breast cancer and regional lymphadenopathy similar to MRI and detects microcalcifications in 80% of cases. Advances in knowledge UHR and spectral capabilities of PCD-CT may allow for comprehensive characterization of breast cancer and may represent an alternative to breast MRI in select cases.
Potential benefits of photon counting detector computed tomography in pediatric imaging
Abstract Photon counting detector (PCD) CT represents the newest advance in CT technology, with improved radiation dose efficiency, increased spatial resolution, inherent spectral imaging capabilities, and the ability to eliminate electronic noise. Its design fundamentally differs from conventional energy integrating detector CT because photons are directly converted to electrical signal in a single step. Rather than converting X-rays to visible light and having an output signal that is a summation of energies, PCD directly counts each photon and records its individual energy information. The current commercially available PCD-CT utilizes a dual-source CT geometry, which allows 66 ms cardiac temporal resolution and high-pitch (up to 3.2) scanning. This can greatly benefit pediatric patients by facilitating high quality fast scanning to allow sedation-free imaging. The energy-resolving nature of the utilized PCDs allows “always-on” dual-energy imaging capabilities, such as the creation of virtual monoenergetic, virtual non-contrast, virtual non-calcium, and other material-specific images. These features may be combined with high-resolution imaging, made possible by the decreased size of individual detector elements and the absence of interelement septa. This work reviews the foundational concepts associated with PCD-CT and presents examples to highlight the benefits of PCD-CT in the pediatric population.
Dynamic CT Angiography in Vascular Imaging: Principles and Applications
Diagnostic Performance in Low- and High-Contrast Tasks of an Image-Based Denoising Algorithm Applied to Radiation Dose–Reduced Multiphase Abdominal CT Examinations
Objective This study aims to determine if low iodine dynamic computed tomography angiography performed after a fixed delay or test bolus acquisition demonstrates high concordance with clinical computed tomography angiography (using a routine amount of iodinated contrast) to display lower extremity peripheral arterial disease. Methods After informed consent, low iodine dynamic computed tomography angiography examination (using either a fixed delay or test bolus) using 50 ml of iodine contrast media was performed. A subsequent clinical computed tomography angiography using standard iodine dose (115 or 145 ml) served as the reference standard. A vascular radiologist reviewed dynamic and clinical computed tomography angiography images to categorize the lumen into “not opacified”, “<50% stenosis”, “ 50 ̶70% stenosis”, “>70% stenosis”, and “occluded” for seven arterial segments in each lower extremity. Concordance between low iodine dynamic computed tomography angiography and the routine iodine reference standard was calculated. The clinical utility of 4D volume-rendered images was also evaluated. Results Sixty-eight patients (average age 66.1 ± 12.3 years, male; female = 49: 19) were enrolled, with 34 patients each undergoing low iodine dynamic computed tomography angiography using fixed delay and test bolus techniques, respectively. One patient assigned to the test bolus group did not undergo low iodine computed tomography angiography due to unavailable delayed time. The fixed delay was 13 s, with test bolus acquisition resulting in a mean variable delay prior to image acquisition of 19.5 s (range; 8–32 s). Run-off to the ankle was observed using low iodine dynamic computed tomography angiography following fixed delay and test bolus acquisition in 76.4% (26/34) and 100% (33/33) of patients, respectively ( p = 0.005). Considering extremities with run-off to the ankle and without severe artifact, the concordance rate between low iodine dynamic computed tomography angiography and the routine iodine reference standard was 86.8% (310/357) using fixed delay and 97.9% (425/434) using test bolus ( p < 0.001). 4D volume-rendered images using fixed delay and test bolus demonstrated asymmetric flow in 57.7% (15/26) and 58.1% (18/31) ( p = 0.978) of patients, and collateral blood flow in 11.5% (3/26) and 22.6% (7/31) of patients ( p = 0.319), respectively. Conclusion Low iodine dynamic computed tomography angiography with test bolus acquisition has a high concordance with routine peripheral computed tomography angiography performed with standard iodine dose, resulting in improved run-off to the ankle compared to dynamic computed tomography angiography performed after a fixed delay. This method is useful for minimizing iodine dose in patients at risk for contrast-induced nephropathy. 4D volume-rendered computed tomography angiography images provide useful dynamic information.
Technical Note: kV‐independent coronary calcium scoring: A phantom evaluation of score accuracy and potential radiation dose reduction
Purpose To determine the accuracy of CT number and calcium score of a kV‐independent technique based on an artificial 120 kV reconstruction, and its potential to reduce radiation dose. Methods Anthropomorphic chest phantoms were scanned on a third‐generation dual‐source CT system equipped with the artificial 120 kV reconstruction. First, a phantom module containing a 20‐mm diameter hydroxyapatite (HA) insert was scanned inside the chest phantoms at different tube potentials (70–140 kV) to evaluate calcium CT number accuracy. Next, three small HA inserts (diameter/length = 5 mm) were inserted into a pork steak and scanned inside the phantoms to evaluate calcium score accuracy at different kVs. Finally, the same setup was scanned using automatic exposure control (AEC) at 120 kV, and then with automatic kV selection (auto‐kV). Phantoms were also scanned at 120 kV using a size‐dependent mA chart. CT numbers of soft tissue and calcium were measured from different kV images. Calcium score of each small HA insert was measured using commercial software. Results The CT number difference from 120 kV was small with tube potentials from 90 to 140 kV for both soft tissue and calcium (maximal difference of 4/5 HU, respectively). Consistent calcium scores were obtained from images of different kVs compared to 120 kV, with a relative difference <8%. Auto‐kV provided a 25–34% dose reduction compared to AEC alone. Conclusion A kV‐independent calcium scoring technique can produce artificial 120 kV images with consistent soft tissue and calcium CT numbers compared to standard 120 kV examinations. When coupled with auto‐kV, this technique can reduce radiation by 25–34% compared to that with AEC alone, while providing consistent calcium scores as that of standard 120 kV examinations.
Image quality in abdominal CT using an iodine contrast reduction algorithm employing patient size and weight and low kV CT technique
Background Low tube potential-high tube current computed tomography (CT) imaging allows reduction in iodine-based contrast dose and may extend the benefit of routine contrast-enhanced CT exams to patients at risk of nephrotoxicity. Purpose To determine the ability of an iodine contrast reduction algorithm to maintain diagnostic image quality for contrast-enhanced abdominal CT. Material and Methods CT exams with iodine contrast reduction were prescribed for patients at risk for renal dysfunction. The iodine contrast reduction algorithm combines weight-based contrast volume reduction with patient width-based low tube potential selection and bolus-tracking. Control exams with routine iodine dose were selected based on weight, width, and scan protocol. Three radiologists evaluated image quality and diagnostic confidence using a 4-point scale (<2 acceptable). Another radiologist assessed contrast reduction indications and measured portal vein and liver contrast-to-noise ratios. Results Forty-six contrast reduction algorithm and control exams were compared (mean creatinine 1.6 vs. 1.2 mg/dL, P ≤ 0.0001). Thirty-nine contrast reduction patients had an eGFR <60 mL/min/1.73m 2 and 15 had single or transplanted kidney. Mean iodine contrast dose was lower in the contrast reduction group (20.9 vs. 39.4 g/mL, P < 0.0001). Diagnostic confidence was rated as acceptable in 95% (131/138) of contrast reduction and 100% of control exams (1.18–1.28 vs. 1.02–1.13, respectively; P > 0.06). Liver attenuation and contrast-to-noise ratio (CNR) were similar ( P = 0.08), but portal vein attenuation and CNR were lower with contrast-reduction (mean 176 vs. 198 HU, P = 0.02; 13 vs. 16, P = 0.0002). Conclusion This size-based contrast reduction algorithm using low kV and bolus tracking reduced iodine contrast dose by 50%, while achieving acceptable image quality in 95% of exams.
Individualized Delay for Abdominal Computed Tomography Angiography Bolus-Tracking Based on Sequential Monitoring: Increased Aortic Contrast Permits Decreased Injection Rate and Lower Iodine Dose
Objective The aim of this study was to determine if computed tomography (CT) angiography using an individualized transition delay (CTA-ID) would facilitate reductions in injection rate and iodine dose. Methods The CTA-ID was performed in 20 patients with routine injection rate and iodine dose; 20 patients with injection rate lowered by 1 mL/s; and 40 patients with injection rate lowered by 1 mL/s with 29% less iodine. Routine CTAs in the same or size-matched patients served as controls. Diagnostic image quality and intra-arterial CT numbers were assessed. Results The median transition delay between aortic threshold and CTA-ID image acquisition was significantly longer than with conventional bolus tracking (mean increase, 13.3 seconds; P < 0.0001), with image quality being the same or better. Intra-arterial CT numbers were 200 Hounsfield units or greater for 80 of 80 CTA-ID, but not for 6 of 49 (12%) internal control or for 11 of 80 (14%) size-matched control patients. Conclusion The CTA-ID bolus-tracking software alters transition delays to permit diagnostic CTA examinations despite slower injection rate and less iodine.