Back to Authors

Rajendran, Kishore

0000-0002-8314-3642

Mayo Clinic

Department of Radiology, Mayo Clinic, Rochester, MN 55905, United States.

Citations 17

Prospective comparison of ultra-high-resolution photon-counting detector CT coronary angiography versus conventional CT
McCollough, Cynthia H. , Davis, Ann A., Weber, Nikkole M. , Kasten, Holly J., Melka, Elnata F., Rajendran, Kishore , Leng, Shuai , Davis, Aeden K, Leng, Shuai , McCollough, Cynthia H , Rajendran, Kishore , Carter, Rickey E.

British Journal of Radiology | September 5, 2025 | Volume: 99 | Issue: 1177 | Pages: 73-82

10.1093/bjr/tqaf220 Get It

Abstract Objectives Determine differences in quantitative stenosis severity measurements for ultra-high-resolution (UHR) photon-counting detector (PCD) coronary CT angiography (cCTA) relative to energy-integrating detector (EID) cCTA in a large patient cohort. Methods Adult participants seen between November 2022 and March 2023 underwent a clinical dual-source EID-CT cCTA and a research dual-source PCD-CT cCTA on the same day. Percent diameter stenosis (PDS) was measured, and stenosis severity was assigned based on the PDS of the most severe lesion per patient to determine a coronary artery disease reporting and data system (CAD-RADS) score. Agreement between EID-CT and PCD-CT for PDS and CAD-RADS was determined. Results A total of 112 participants were enrolled, yielding 82 subjects with at least 1 stenosis at PCD-CT (mean age, 68.0 ± 10.8 years; 69.5% [57/82] males). A total of 177 paired stenoses were quantified. The percent decrease in mean PDS from PCD-CT (24.3%) to EID-CT (29.4%) was 17.3% (median difference in PDS: −5.0%, 95% CI: −5.7% to −4.0%). The assigned CAD-RADS score changed in 31/82 subjects. In 11/31 subjects, the most severe stenosis was missed at EID-CT due to partial volume averaging of a small calcification, yet PCD clearly identified stenosis at those locations. In 20/31 subjects, the CAD-RADS score decreased at PCD-CT due to the decreased calcium blooming resulting from the improved spatial resolution. Conclusions UHR PCD cCTA decreases quantitative measures of stenosis severity when a stenosis is identified at EID, leading to decreases in CAD-RADS assignments. Advances in knowledge With its improved spatial resolution, PCD-CT identifies stenoses missed on EID-CT.
Photon-counting detector CT in musculoskeletal imaging: benefits and outlook
Sadaney, Ahmed O El , Ferrero, Andrea , Rajendran, Kishore , Booij, Ronald , Marcus, Roy , Sutter, Reto , Oei, E.H. , Baffour, Francis , El Sadaney, Ahmed O , Rajendran, Kishore , Baffour, Francis I

British Journal of Radiology | June 6, 2025 | Volume: 98 | Issue: 1175 | Pages: 1859-1862

10.1093/bjr/tqaf124 Get It

Abstract Photon-counting detector CT (PCD-CT) represents a significant advancement in medical imaging, particularly for musculoskeletal (MSK) applications. Its primary innovation lies in enhanced spatial resolution, which facilitates improved detection of small anatomical structures such as trabecular bone, osteophytes, and subchondral cysts. PCD-CT enables high-quality imaging with reduced radiation doses, making it especially beneficial for populations requiring frequent imaging, such as paediatric patients and individuals with multiple myeloma. Additionally, PCD-CT supports advanced applications like bone quality assessment, which correlates well with gold-standard tests, and can aid in diagnosing osteoporosis and assessing fracture risk. Techniques such as spectral shaping and virtual monoenergetic imaging further optimize the technology, minimizing artefacts and enhancing material decomposition. These capabilities extend to conditions like gout and haematologic malignancies, offering improved detection and assessment. The integration of artificial intelligence could enhance PCD-CT’s performance by reducing image noise and improving quantitative assessments. Ultimately, PCD-CT’s superior resolution, reduced dose protocols, and multi-energy imaging capabilities will likely have a transformative impact on MSK imaging, improving diagnostic accuracy, patient care, and clinical outcomes.
Quantitative CT imaging: where are we, and what is missing?
Treb, Kevin , Sadaney, Ahmed O El , Ferrero, Andrea , Leng, Shuai , Yu, Lifeng , McCollough, Cynthia H. , Rajendran, Kishore , Treb, Kevin J, El Sadaney, Ahmed O , Leng, Shuai , Yu, Lifeng , Rajiah, Prabhakar Shantha, McCollough, Cynthia H , Rajendran, Kishore , Treb, Kevin , Baffour, Francis , Rajiah, Prabhakar , Fletcher, Joel G.

British Journal of Radiology | April 7, 2025 | Volume: 98 | Issue: 1175 | Pages: 1834-1842

10.1093/bjr/tqaf075 Get It

Abstract Quantitative computed tomography (CT) enables the measurement of biophysical processes characterized by morphology, composition, flow, and/or motion to aid in clinical diagnosis and intervention. Since its initial application for determining bone mineral density for skeletal fragility assessment, quantitative CT has continued to evolve alongside CT’s technological advancements. A key challenge facing quantitative CT is the lack of standardization pertinent to image acquisition, reconstruction, and image analysis. With the introduction of spectral CT involving dual-energy approaches and photon-counting detectors (PCD), we are now able to obtain detailed information regarding mass densities of endogenous and exogeneous materials. Furthermore, energy-resolved CT yields spectral image types (eg, virtual monoenergetic image) that are, in principle, independent of tube potential and patient size. This paves the way for workflow standardization and helps improve the consistency and reproducibility of CT-derived measurements. In this article, we review clinical applications of quantitative CT, discuss key challenges associated with quantitative CT and its adoption into routine practice, and outline the unique benefits ushered by new CT technologies such as PCD-CT towards improving quantitative imaging.
Safety Net Reconstruction to Catch Low-Density and Low-Volume Calcifications at Photon-Counting Detector CT Using Virtual Noncontrast Imaging
Rajendran, Kishore , Rajiah, Prabhakar , Rajendran, Kishore , Rajiah, Prabhakar

Radiology: Cardiothoracic Imaging | August 22, 2024 | Volume: 6 | Issue: 4 | Pages: No page available

10.1148/ryct.240266 Get It

Task-based automatic keV selection: leveraging routine virtual monoenergetic imaging for dose reduction on clinical photon-counting detector CT *
Rajendran, Kishore , Bruesewitz, Michael R. , Swicklik, Joseph R., Ferrero, Andrea , Thorne, Jamison E. , Yu, Lifeng , Bruesewitz, Michael, Swicklik, Joseph, Thorne, Jamison, McCollough, Cynthia, Rajendran, Kishore , Yu, Lifeng , McCollough, Cynthia H. , Leng, Shuai

Physics in Medicine & Biology | April 22, 2024 | Volume: 69 | Issue: 11 | Pages: 115029

10.1088/1361-6560/ad41b3 Get It

Abstract Objective . Photon-counting detector (PCD) CT enables routine virtual-monoenergetic image (VMI) reconstruction. We evaluated the performance of an automatic VMI energy level (keV) selection tool on a clinical PCD-CT system in comparison to an automatic tube potential (kV) selection tool from an energy-integrating-detector (EID) CT system from the same manufacturer. Approach. Four torso-shaped phantoms (20–50 cm width) containing iodine (2, 5, and 10 mg cc −1 ) and calcium (100 mg cc −1 ) were scanned on PCD-CT and EID-CT. Dose optimization techniques, task-based VMI energy level and tube-potential selection on PCD-CT (CARE keV) and task-based tube potential selection on EID-CT (CARE kV), were enabled. CT numbers, image noise, and dose-normalized contrast-to-noise ratio (CNR d ) were compared. Main results . PCD-CT produced task-specific VMIs at 70, 65, 60, and 55 keV for non-contrast, bone, soft tissue with contrast, and vascular settings, respectively. A 120 kV tube potential was automatically selected on PCD-CT for all scans. In comparison, EID-CT used x-ray tube potentials from 80 to 150 kV based on imaging task and phantom size. PCD-CT achieved consistent dose reduction at 9%, 21% and 39% for bone, soft tissue with contrast, and vascular tasks relative to the non-contrast task, independent of phantom size. On EID-CT, dose reduction factor for contrast tasks relative to the non-contrast task ranged from a 65% decrease (vascular task, 70 kV, 20 cm phantom) to a 21% increase (soft tissue with contrast task, 150 kV, 50 cm phantom) due to size-specific tube potential adaptation. PCD-CT CNR d was equivalent to or higher than those of EID-CT for all tasks and phantom sizes, except for the vascular task with 20 cm phantom, where 70 kV EID-CT CNR d outperformed 55 keV PCD-CT images. Significance . PCD-CT produced more consistent CT numbers compared to EID-CT due to standardized VMI output, which greatly benefits standardization efforts and facilitates radiation dose reduction.
Comparison of Photon-counting Detector and Energy-integrating Detector CT for Visual Estimation of Coronary Percent Luminal Stenosis
McCollough, Cynthia H. , Bois, John P. , Winfree, Tim N., Carter, Rickey E. , Rajendran, Kishore , Williamson, Eric E. , Thorne, Jamison E. , Leng, Shuai , Rajiah, Prabhakar , Winfree, Tim N , Carter, Rickey E , Rajendran, Kishore , Williamson, Eric , Thorne, Jamison E , Leng, Shuai , McCollough, Cynthia H , Rajiah, Prabhakar

Radiology | December 5, 2023 | Volume: 309 | Issue: 3 | Pages: No page available

10.1148/radiol.230853 Get It

Ex vivo coronary calcium volume quantification using a high-spatial-resolution clinical photon-counting-detector computed tomography
Marsh, Jeffrey F., VanMeter, Patrick D., Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | July 4, 2023 | Volume: 10 | Issue: 04 | Pages: No page available

10.1117/1.jmi.10.4.043501 Get It

Measurement of enhanced vasa vasorum density in a porcine carotid model using photon counting detector CT
Marsh, Jeffrey F., Vercnocke, Andrew J. , Tao, Shengzhen , Anderson, Jill , Ritman, Erik L., Rajendran, Kishore , Anderson, Jill L, Leng, Shuai , McCollough, Cynthia H , Rajendran, Kishore , Leng, Shuai , McCollough, Cynthia H.

Journal of Medical Imaging | February 6, 2023 | Volume: 10 | Issue: 01 | Pages: No page available

10.1117/1.jmi.10.1.016001 Get It

Dedicated convolutional neural network for noise reduction in ultra-high-resolution photon-counting detector computed tomography
Huber, Nathan R. , Ferrero, Andrea , Rajendran, Kishore , Glazebrook, Katrina N. , Yu, Lifeng , Baffour, Francis , Diehn, Felix E. , Inoue, Akitoshi , Rajendran, Kishore , Huber, Nathan Robert , Fletcher, Joel G. , Yu, Lifeng , Leng, Shuai , McCollough, Cynthia H.

Physics in Medicine & Biology | August 9, 2022 | Volume: 67 | Issue: 17 | Pages: 175014

10.1088/1361-6560/ac8866 Get It

Abstract Objective. To develop a convolutional neural network (CNN) noise reduction technique for ultra-high-resolution photon-counting detector computed tomography (UHR-PCD-CT) that can be efficiently implemented using only clinically available reconstructed images. The developed technique was demonstrated for skeletal survey, lung screening, and head angiography (CTA). Approach . There were 39 participants enrolled in this study, each received a UHR-PCD and an energy integrating detector (EID) CT scan. The developed CNN noise reduction technique uses image-based noise insertion and UHR-PCD-CT images to train a U-Net via supervised learning. For each application, 13 patient scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) and allocated into training, validation, and testing datasets (9:1:3). The subtraction of FBP and IR images resulted in approximately noise-only images. The 5-slice average of IR produced a thick reference image. The CNN training input consisted of thick reference images with reinsertion of spatially decoupled noise-only images. The training target consisted of the corresponding thick reference images without noise insertion. Performance was evaluated based on difference images, line profiles, noise measurements, nonlinear perturbation assessment, and radiologist visual assessment. UHR-PCD-CT images were compared with EID images (clinical standard). Main results. Up to 89% noise reduction was achieved using the proposed CNN. Nonlinear perturbation assessment indicated reasonable retention of 1 mm radius and 1000 HU contrast signals (>80% for skeletal survey and head CTA, >50% for lung screening). A contour plot indicated reduced retention for small-radius and low contrast perturbations. Radiologists preferred CNN over IR for UHR-PCD-CT noise reduction. Additionally, UHR-PCD-CT with CNN was preferred over standard resolution EID-CT images. Significance. CT images reconstructed with very sharp kernels and/or thin sections suffer from increased image noise. Deep learning noise reduction can be used to offset noise level and increase utility of UHR-PCD-CT images.