Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Surgical and Transcatheter Mitral Valve Replacement in Mitral Annular Calcification: A Systematic Review
Abstract Mitral annular calcification with mitral valve disease is a challenging problem that could necessitate surgical mitral valve replacement (SMVR). Transcatheter mitral valve replacement (TMVR) is emerging as a feasible alternative in high‐risk patients with appropriate anatomy. PubMed, Embase, and Cochrane Central Register of Controlled Trials were searched from inception to December 25, 2019 for studies discussing SMVR or TMVR in patients with mitral annular calcification; 27 of 1539 articles were selected for final review. TMVR was used in 15 studies. Relevant data were available on 82 patients who underwent hybrid transatrial TMVR, and 354 patients who underwent transapical or transseptal TMVR. Outcomes on SMVR were generally reported as small case series (447 patients from 11 studies); however, 1 large study recently reported outcomes in 9551 patients. Patients who underwent TMVR had a shorter median follow‐up of 9 to 12 months (range, in‐hospital‒19 months) compared with patients with SMVR (54 months; range, in‐hospital‒120 months). Overall, those undergoing TMVR were older and had higher Society of Thoracic Surgeons risk scores. SMVR showed a wide range of early (0%–27%; median 6.3%) and long‐term mortality (0%–65%; median at 1 year, 15.8%; 5 years, 38.8%, 10 years, 62.4%). The median in‐hospital, 30‐day, and 1‐year mortality rates were 16.7%, 22.7%, and 43%, respectively, for transseptal/transapical TMVR, and 9.5%, 20.0%, and 40%, respectively, for transatrial TMVR. Mitral annular calcification is a complex disease and TMVR, with a versatile option of transatrial approach in patients with challenging anatomy, offers a promising alternative to SMVR in high‐risk patients. However, further studies are needed to improve technology, patient selection, operative expertise, and long‐term outcomes.
Imaging in patients with severe mitral annular calcification: insights from a multicentre experience using transatrial balloon-expandable valve replacement
Abstract Aims To investigate valve sizing and the haemodynamic relevance of the predicted left ventricular outflow tract (LVOT) in patients with mitral annular calcification (MAC) undergoing transatrial transcatheter valve implantation (THV). Methods and results In total, 21 patients undergoing transatrial THV, multiplanar reconstruction (MPR), maximum intensity projection (MIP), and cubic spline interpolation (CSI) were compared for MA sizing during diastole. In addition, predicted neo-LVOT areas were measured in 18 patients and correlated with the post-procedural haemodynamic dimensions. The procedure was successful in all patients (100%). Concomitant aortic valve replacement was performed in eight patients (43%) (AVR group). Sizing using MPR and MIP yielded comparable results in terms of area, perimeter, and diameter, whereas the dimensions obtained with CSI were systematically smaller. The simulated mean systolic neo-LVOT area was 133.4 ± 64.2 mm2 with an anticipated relative LVOT area reduction (neo-LVOT area/LVOT area × 100) of 59.3 ± 14.7%. The systolic relative LVOT area reduction, but not the absolute neo-LVOT area, was found to predict the peak (r = 0.69; P = 0.002) and mean (r = 0.65; P = 0.004) post-operative aortic gradient in the overall population as well as separately in the AVR (peak: r = 0.91; P = 0.002/mean: r = 0.85; P = 0.002) and no-AVR (peak: r = 0.89; P = 0.003/mean: r = 0.72; P = 0.008) groups. Conclusion In patients with severe MAC undergoing transatrial transcatheter valve implantation, MPR, and MIP yielded comparable annular dimensions, while values obtained with CSI tended to be systematically smaller. Mitral annular area and the average annular diameter appear to be reliable parameters for valve selection. Simulated relative LVOT reduction was found to predict the post-procedural aortic gradients.