Abstract Introduction Left atrial-to-coronary sinus (LA-to-CS) shunting through the APTURE transcatheter shunt system aims to unload the LA while preserving the interatrial septum. This article aims to examine the 3-year health status, functional capacity, and clinical outcomes of the ALT-FLOW Early Feasibility Study (EFS). Methods Device safety, patency, and echocardiographic parameters, but also symptoms, health status, and exercise capacity were assessed in patients with left ventricular ejection fraction (LVEF) > 40% (n & 95). Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score predicted 3-year all-cause mortality was compared with observed mortality assessed by Kaplan–Meier analysis using adjudicated events. Predicted and observed HF hospitalization (HFH)-free survival rates were also compared. Results At 3 years, the safety profile remained stable with no new safety signals, and all implanted shunts remained patent. 76.3% of patients improved by at least one NYHA class, and mean KCCQ Overall Summary Scores increased by 25 points from baseline (P < .0001). The 6-min walk distance improved by an average of 39 m (P & .002). These benefits were consistent regardless of baseline pulmonary vascular resistance (PVR). Right heart echocardiographic parameters after 3 years were stable, though a reduction in TAPSE was observed, primarily in the high PVR subgroup. The observed 3-year survival was significantly higher than the MAGGIC-predicted survival (84.4% vs 70.2, respectively; P & .009), as well as the HFH-free survival (68.0% vs 24.0%, respectively; P < 0001). Conclusion In patients with HF and LVEF >40%, the APTURE LA-to-CS shunting confirmed an acceptable safety profile with stable right heart parameters and sustained improvements in symptoms, quality of life, and functional capacity at 3 years. Observed survival and HFH were superior to MAGGIC predictions.
Acute Valve Syndrome Before Aortic Valve Replacement: Impact on Clinical Outcomes, Health Care Costs, and Resource Use
Background A classification system describing clinical presentation before aortic valve replacement (AVR) has recently been proposed (stable valve syndrome [SVS]), mildly symptomatic (progressive valve syndrome), or with acute and severe signs and symptoms (acute valve syndrome [AVS]). We aimed to evaluate the clinical impact, health care costs, and resource use associated with the mode of clinical presentation at the time of AVR among patients presenting with aortic stenosis. Methods Using the Market Clarity database (2017–2023), patients >18 years old with aortic stenosis and undergoing AVR (transcatheter or surgical) were included. Patients were categorized as SVS, progressive valve syndrome, or AVS based on their clinical presentation during the 1 year before AVR. All‐cause death, heart failure hospitalization, total health care costs (index hospitalization plus 1‐year follow‐up), and resource use were compared across clinical presentation groups using adjusted regression models. Results Of the 24 075 patients undergoing AVR for aortic stenosis, 270 (1.1%) had SVS, 10 195 (42.3%) progressive valve syndrome, and 13 610 (56.5%) AVS. Compared with SVS, AVS presentation was associated with increased risk of 1‐year death (adjusted hazard ratio [aHR], 2.93 [95% CI, 1.1–7.8]; P =0.03) and heart failure hospitalization (aHR, 4.15 [95% CI, 1.6–11.1]; P <0.01) after AVR. The total costs of AVR and 1‐year follow‐up were significantly higher in both the progressive valve syndrome (difference $27 410 [$13 507–$41 314]) and AVS groups (difference $36 267 [$22 302–$50 232]) compared with patients with SVS. Conclusions AVS was frequent among patients undergoing AVR and was associated with increase in death, heart failure hospitalization, health care costs, and resource use 1 year after AVR, and SVS presentation was associated with the best clinical and economic outcomes.
Transcatheter Valve Replacement in Severe Tricuspid Regurgitation
Left Atrial to Coronary Sinus Shunting for Treatment of Heart Failure with Mildly Reduced or Preserved Ejection Fraction: The ALT FLOW Early Feasibility Study 1-Year Results
Abstract Aims Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. Methods and results Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was −5.7 (−8.6, −2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I–II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20–30) and 27 (22–32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. Conclusions In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P &lt; .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P &lt; .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P &lt; .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Early outcomes from the
CLASP IID
trial roll‐in cohort for prohibitive risk patients with degenerative mitral regurgitation