Back to Authors

Yadav, Pradeep

https://orcid.org/0000-0003-1278-9136

Mayo Clinic

Northwestern University

Citations 3

Contemporary Outcomes and Trends for the Transseptal Mitral Valve-in-Valve Procedure Using Balloon Expandable Transcatheter Valves in the United States
Goel, Kashish , Makkar, Raj , Krishnaswamy, Amar , Kapadia, Samir , Kodali, Susheel , Shah, Ashish S. , Barker, Colin M. , Xu, Ke , Dhoble, Abhijeet , Yadav, Pradeep , Rihal, Charanjit S. , Abbas, Amr E. , Kapadia, Samir , Guerrero, Mayra E , Whisenant, Brian K. , Rihal, Charanjit S. , Guerrero, Mayra

Circulation | August 5, 2024 | Volume: 150 | Issue: 19 | Pages: 1493-1504

10.1161/circulationaha.124.068847 Get It

BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean±SD STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year ( P <0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4–8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital ( P =0.0005), 30-day ( P =0.004), and 1-year mortality rates ( P =0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, acceptable 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.
Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Wood, David , Krajcer, Zvonimir , Sathananthan, Janarthanan , Strickman, Neil E., Metzger, Chris, Fearon, William F. , Aziz, Mark, Satler, Lowell F. , Waksman, Ron , Eng, Marvin H. , Heimansohn, David, Sampson, Andrew, Coady, Paul , Rodriguez, Roberto , Krishnaswamy, Amar , Lee, Jason T. , Ben‐Dor, Itsik , Moainie, Sina L. , Kodali, Susheel , Yadav, Pradeep , Kozak, Mark, Bacharach, J. Michael, Feldman, Ted , Nanjundappa, Aravinda , Bersin, Robert M., Potluri, Srinivasa , Barker, Colin M. , Bernardo, Nelson L. , Lumsden, Alan B. , Dake, Michael D. , Brown, David L. , Maor, Nathaniel, Nardone, Samuel, Webb, John G. , Investigators, on behalf of the SAFE MANTA Study, Kapadia, Samir , Greenbaum, Adam B. , Szerlip, Molly , Chhatriwalla, Adnan K , O’Neill, Brian Patrick , Guerrero, Mayra , Zhang, Ming , Barleben, Andrew R. , Campbell, John , Cohen, David Jonathan , Lauck, Sandra , O’Neill, William W. , Investigators, on behalf of the SAFE MANTA Study

Circulation: Cardiovascular Interventions | July 12, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007258 Get It

Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.