4 year outcomes in a prospective evaluation of transcatheter mitral valve-in-valve, valve-in-ring and valve-in-mitral annular calcification: results from the MITRAL trial
Abstract Background The MITRAL Trial (Mitral Implantation of TRAnscatheter vaLves) evaluates the safety and feasibility of balloon-expandable aortic transcatheter heart valves in patients with severe mitral valve disease with mitral annular calcification (MAC), failed surgical rings or failed bioprostheses. Purpose We sought to evaluate 4-year outcomes of patients enrolled in the MITRAL trial. Methods This is a prospective study that enrolled 91 high surgical risk patients at 13 sites in the U.S. 30 patients underwent Mitral Valve-in-Valve (MViV), 30 Valve-in-Ring (MViR) and 31 Valve-in-MAC (ViMAC). 4-year outcomes of these patients were evaluated in this analysis. Primary endpoints and key serious adverse events including deaths were adjudicated by an independent Clinical Events Committee. Cardiac computed tomography (CT) and echocardiographic images were evaluated by independent CT and Echocardiographic Core Laboratories. Results Mean age was 74.3±8.9 years. Most patients undergoing MViV and ViMAC were female (MVIV=63.3%, MViR=36.7% and ViMAC=71%). Mean STS score was 9.2±6.6% (MViV 10.2±6.5%, MViR 8.7±4.7%, ViMAC=8.6±8.2%). All-cause mortality at 4 years was higher for ViMAC and MViR: MViV=6.9% (cardiovascular 3.4%), MViR=48.1% (cardiovascular 18.5%), ViMAC=51.9% (cardiovascular 29.6%), p=0.002 (Figure 1). At 4 years, all survivors had ≤1+ mitral regurgitation and most had none or trace mitral regurgitation (MViV=87.5, MViR=33.3% and ViMAC=100%). Mean mitral valve gradients remained stable (MViV=5.9±2.2 mmHg, MViR= 6.6±5.1 mmHg, ViMAC=5.1±1.0 mmHg), Figure 2. Most survivors experienced significant improvement of symptoms and were in NYHA class I-II at 4-year follow-up (MViV=78.9%, MViR=66.7% and ViMAC=66.7%). Conclusions MViV is associated with excellent outcomes at 4 years. MViR and ViMAC were associated with higher mortality at 4 years. However, most survivors in all groups experienced sustained improvement of symptoms and stable THV performance at 4 years. Whether survival bias had an impact on THV performance and improved symptoms at follow-up is not known and deserves further evaluation. Funding Acknowledgement Type of funding sources: Private company. Main funding source(s): Unrestricted Research Grant from Edwards Lifesciences.
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P < .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P < .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P < .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Abstract 23085: 30-Day Outcomes of Transseptal Transcatheter Mitral Valve Replacement for Failed Surgical Bioprostheses (Mitral Valve-in-Valve): The MITRAL Trial (Mitral Implantation of TRAnscatheter vaLves)
Introduction: Transcatheter mitral valve replacement (TMVR) using aortic transcatheter heart valves (THV) is developing as an alternative to surgery for patients with severely degenerated mitral valve (MV) bioprostheses. Retrospective self-reported registries have collected outcomes on these TMVR procedures in the STS/ACC Transcatheter Valve Therapy Registry and in the Valve-in-Valve International Database. Most reported TMVR procedures for failed surgical bioprostheses have been performed using a transapical access approach. A prospective comprehensive evaluation of mitral Valve-in-Valve (VIV) outcomes, including transseptal access has not previously been conducted. Objectives: To evaluate in-hospital and 30-day clinical outcomes of transseptal mitral VIV with SAPIEN 3 THV in patients with very high surgical risk. Methods: Prospective enrollment of very high surgical risk patients with symptomatic severely degenerated MV surgical bioprostheses in 30 patients at 15 sites in the U.S. Candidates were assessed by a case review committee prior to approval. Baseline qualifying echocardiograms and cardiac CT studies were analyzed by independent core labs. Echocardiograms, cardiac CT studies and neurology evaluations were also performed after mitral VIV procedures. Clinical events were adjudicated by a clinical events committee and safety was monitored by a data safety monitoring board. Results: 26 patients have been enrolled between July 2016 and June 2017. Mean age was 83 years, 62% female, mean STS score was 10% and 62% were in New York Heart Association class III or IV. Transseptal access was used in all procedures. Technical success was achieved in all patients and there was no in-hospital mortality. There was no 30-day cardiovascular mortality and 4% (1 patient) 30-day all-cause mortality (1 patient died of asphyxia on day 29 after choking on pills at home), which was lower than the 30-day mortality in the TVT registry (9%). Detailed procedural, in-hospital and 30-day outcomes will be presented on the complete cohort of 30 patients. Conclusions: In patients without surgical alternatives, transseptal mitral ViV procedures in failed surgical bioprostheses are associated with high technical and procedural success and low 30-day mortality.
Early outcomes from the
CLASP IID
trial roll‐in cohort for prohibitive risk patients with degenerative mitral regurgitation
Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.