Back to Authors

Krishnaswamy, Amar

https://orcid.org/0000-0001-6048-7955

Mayo Clinic

Cleveland Clinic

Citations 7

Contemporary Outcomes of TAVR Using a Balloon-Expandable Valve in Patients With Severe Mitral Stenosis: Insights From the Transcatheter Valve Therapies Registry
Ahmad, Imran, Flaherty, James D. , Nagaraja, Vinayak , Huded, Chetan , Reed, Grant W. , Puri, Rishi , Rassi, Andrew N., Goel, Sachin S. , Jneid, Hani , Zahr, Firas , Krishnaswamy, Amar , Kumar, Anirudh , Flaherty, James D , Nagaraja, Vinayak , Huded, Chetan P , Reed, Grant W , Puri, Rishi , Goel, Sachin S , Jneid, Hani , McCabe, James M , Guerrero, Mayra E , Zahr, Firas , Krishnaswamy, Amar , Kapadia, Samir , Ahmad, Imran N., Guerrero, Mayra , Kapadia, Samir

Circulation: Cardiovascular Interventions | November 22, 2024 | Volume: 17 | Issue: 12 | Pages: No page available

10.1161/circinterventions.124.014216 Get It

BACKGROUND: While initial data for transcatheter aortic valve replacement (TAVR) in aortic stenosis patients with mitral stenosis (MS) suggested a poor short-term prognosis, outcomes for contemporary balloon-expandable valves remain unknown. The aim of this retrospective multicenter registry study was to compare the potential impact of MS on TAVR outcomes with balloon-expandable valves. METHODS: Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry and Centers for Medicare & Medicaid Services claims data were used to obtain a cohort of 327 925 patients who underwent TAVR with current balloon-expandable valves (SAPIEN 3, SAPIEN 3 Ultra, or SAPIEN 3 Ultra Resilia) between June 2015 and December 2022 across 791 sites. Severe MS (defined as >10 mm Hg mean gradient or <1.5 cm 2 area) was compared with mild or less MS (defined as <5 mm Hg mean gradient and >2 cm 2 area) using propensity matching to minimize confounding variables. RESULTS: Patients with severe MS (n=8500; 2.6%) had a higher number of comorbid conditions, Society of Thoracic Surgeons risk scores, and were more often women than patients with mild or less MS at the time of index TAVR. While patients with severe MS had worse outcomes at 30 days, when propensity-matched, patients exhibited similar 30-day rates of death (3.2% versus 3.0%), stroke (2.4% versus 2.2%), major vascular complications (1.6% versus 1.6%), device implant success (98.9% versus 99.2%), and new dialysis (0.7% versus 0.5%), with higher rates of pacemaker implantation (11.3% versus 9.4%; P <0.001). By 1 year, there was no difference in the change in the KCCQ (Kansas City Cardiomyopathy Questionnaire) overall score from baseline to 1 year (30.7±27.0 versus 31.9±27.0; P =0.07). By 3 years, an increase in the mortality rate (45.1% versus 40.9%; P <0.001) of patients with severe MS was observed. CONCLUSIONS: MS in isolation is not associated with worsened short-term outcomes among patients undergoing contemporary TAVR with balloon-expandable valves.
Contemporary Outcomes and Trends for the Transseptal Mitral Valve-in-Valve Procedure Using Balloon Expandable Transcatheter Valves in the United States
Goel, Kashish , Makkar, Raj , Krishnaswamy, Amar , Kapadia, Samir , Kodali, Susheel , Shah, Ashish S. , Barker, Colin M. , Xu, Ke , Dhoble, Abhijeet , Yadav, Pradeep , Rihal, Charanjit S. , Abbas, Amr E. , Kapadia, Samir , Guerrero, Mayra E , Whisenant, Brian K. , Rihal, Charanjit S. , Guerrero, Mayra

Circulation | August 5, 2024 | Volume: 150 | Issue: 19 | Pages: 1493-1504

10.1161/circulationaha.124.068847 Get It

BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean±SD STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year ( P <0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4–8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital ( P =0.0005), 30-day ( P =0.004), and 1-year mortality rates ( P =0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, acceptable 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.
Implementing a comprehensive STEMI protocol to improve care metrics and outcomes in patients with in-hospital STEMI: an observational cohort study
Kanaan, Christopher , Kassis, Nicholas , Kravitz, Kathleen, Reed, Grant W. , Krishnaswamy, Amar , Puri, Rishi , Nair, Ravi, Khot, Umesh N. , Kanaan, Christopher N , Kumar, Anirudh , Reed, Grant W , Nair, Raunak Mohan , Huded, Chetan , Lincoff, A. Michael , Khatri, Jaikirshan J , Ziada, Khaled M. , Kapadia, Samir

Open Heart | January 30, 2024 | Volume: 11 | Issue: 1 | Pages: e002505

10.1136/openhrt-2023-002505 Get It

Background Patients who experience in-hospital ST-segment elevation myocardial infarction (iSTEMI) represent a uniquely high-risk cohort owing to delays in diagnosis, prolonged time to reperfusion and increased mortality. Quality initiatives aimed at improving the care of this vulnerable, yet understudied population are needed. Methods This study included consecutive patients with iSTEMI treated with percutaneous coronary intervention (PCI) between 1 January 2011 and 15 July 2019 at a single, tertiary referral centre. A comprehensive iSTEMI protocol (CSP) was implemented on 15 July 2014, incorporating: (1) cardiology fellow activation of the catheterisation lab using standardised criteria, (2) nursing chest pain protocol, (3) improved electronic access to electrocardiographic studies, (4) checklist for initial triage and management, (5) 24/7/365 catheterisation lab readiness and (6) radial-first PCI approach. Key metrics and clinical outcomes were compared before and after CSP implementation. Results Among 125 total subjects, the post-CSP cohort (n=81) was younger, had more males and were more likely to be hospitalised for cardiac-related reasons relative to the pre-CSP cohort (n=44) who were more likely hospitalised for operative-related aetiologies. After CSP adoption, median ECG-to-first-device-activation time decreased from 113 min to 64 min (p<0.001), goal ECG-to-first-device-activation time increased from 36% to 76% of patients (p<0.001), administration of guideline-directed medical therapy prior to PCI increased from 27.3% to 65.4% (p<0.001), trans-radial access increased from 16% to 70% (p<0.001) and rates of discharge home increased from 56.8% to 76.5% (p=0.04). Statistically insignificant numerical reductions were observed post-CSP in in-hospital mortality (18.2% vs 9.9%, p=0.30), 30-day mortality (15.9% vs 12.3%, p=0.78) and 1-year mortality (27.3% vs 21.0%, p=0.57). Conclusions The implementation of a CSP was associated with marked enhancements in key care metrics among patients with iSTEMI. Among a larger cohort, the use of a CSP yielded a significant reduction in ECG-to-first-device-activation time in a particularly vulnerable population at high risk of death.
Implications of Atrial Fibrillation on the Mechanisms of Mitral Regurgitation and Response to MitraClip in the COAPT Trial
Gertz, Zachary M. , Herrmann, Howard C. , Lim, D. Scott , Kapadia, Samir , Reed, Grant W. , Puri, Rishi , Krishnaswamy, Amar , Gersh, Bernard J. , Weissman, Neil J., Grayburn, Paul , Redfors, Björn , Zhang, Zixuan , Abraham, William T. , Stone, Gregg W. , Mack, Michael J. , Kapadia, Samir , Herrmann, Howard C , Gersh, Bernard J , Reed, Grant W , Lim, D Scott , Kar, Saibal , Asch, Federico M. , Kosmidou, Ioanna , Lindenfeld, JoAnn

Circulation: Cardiovascular Interventions | March 15, 2021 | Volume: 14 | Issue: 4 | Pages: No page available

10.1161/circinterventions.120.010300 Get It

Background: Atrial fibrillation (AF), mitral regurgitation (MR), and left ventricular (LV) ejection fraction have a complex interplay. We evaluated the role of AF in patients with heart failure and moderate-to-severe or severe secondary MR enrolled in the randomized COAPT trial (Cardiovascular Outcomes Assessment of the MitraClip Percutaneous Therapy for Heart Failure Patients With Functional Mitral Regurgitation) and its impact on mechanisms and outcomes with the MitraClip. Methods: Patients in the COAPT trial were stratified by the presence (n=327) or absence (n=287) of a history of AF and by assignment to treatment group. Clinical, echocardiographic, and outcome measures were assessed. The primary outcome was the composite rate of death or heart failure hospitalization at 24 months. Results: Patients with history of AF were older and more often male. They had a higher LV ejection fraction, larger left atrial volumes and mitral valve orifice areas, smaller LV volumes, and similar MR severity. Patients with AF compared with those without a history of AF had a higher unadjusted (hazard ratio [HR], 1.32 [95% CI, 1.06–1.64], P =0.01) and adjusted (HR, 1.30 [1.03–1.64], P =0.03) 2-year rate of the primary outcome. Treatment with the MitraClip compared with guideline-directed medical therapy alone reduced death or heart failure hospitalization in both those with (HR, 0.61 [0.46–0.82]) and without (HR, 0.46 [0.33–0.66]) a history of AF ( P int =0.18). Treatment with the MitraClip was associated with a lower risk of stroke in patients with a history of AF (HR, 0.18 [0.04–0.86]) but not in those without a history of AF (HR, 1.64 [0.58–4.62]; P int =0.02). Conclusions: In the COAPT trial, patients with a history of AF had larger left atrial and mitral valve orifice areas with higher LV ejection fraction and smaller LV volumes, suggesting an atrial mechanism contribution to functional MR. Despite the worse prognosis of heart failure patients with a history of AF, MR reduction with the MitraClip still afforded substantial clinical benefits. Treatment with MitraClip was associated with a lower risk of stroke in patients with a history of AF. Registration: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01626079.
One-Year Outcomes of Mitral Valve-in-Valve Using the SAPIEN 3 Transcatheter Heart Valve
Eleid, Mackram F. , Kodali, Susheel , Krishnaswamy, Amar , Morse, Michael A. , Smalling, Richard W. , Reisman, Mark, Mack, Michael J. , Bapat, Vinayak , Leon, Martin B. , Rihal, Charanjit S. , Makkar, Raj , Whisenant, Brian K. , Kapadia, Samir , McCabe, James M , O’Neill, William W. , Rihal, Charanjit S. , Guerrero, Mayra

JAMA Cardiology | July 29, 2020 | Volume: 5 | Issue: 11 | Pages: 1245

10.1001/jamacardio.2020.2974 Get It

Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Wood, David , Krajcer, Zvonimir , Sathananthan, Janarthanan , Strickman, Neil E., Metzger, Chris, Fearon, William F. , Aziz, Mark, Satler, Lowell F. , Waksman, Ron , Eng, Marvin H. , Heimansohn, David, Sampson, Andrew, Coady, Paul , Rodriguez, Roberto , Krishnaswamy, Amar , Lee, Jason T. , Ben‐Dor, Itsik , Moainie, Sina L. , Kodali, Susheel , Yadav, Pradeep , Kozak, Mark, Bacharach, J. Michael, Feldman, Ted , Nanjundappa, Aravinda , Bersin, Robert M., Potluri, Srinivasa , Barker, Colin M. , Bernardo, Nelson L. , Lumsden, Alan B. , Dake, Michael D. , Brown, David L. , Maor, Nathaniel, Nardone, Samuel, Webb, John G. , Investigators, on behalf of the SAFE MANTA Study, Kapadia, Samir , Greenbaum, Adam B. , Szerlip, Molly , Chhatriwalla, Adnan K , O’Neill, Brian Patrick , Guerrero, Mayra , Zhang, Ming , Barleben, Andrew R. , Campbell, John , Cohen, David Jonathan , Lauck, Sandra , O’Neill, William W. , Investigators, on behalf of the SAFE MANTA Study

Circulation: Cardiovascular Interventions | July 12, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007258 Get It

Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.
Durability Data for Bioprosthetic Surgical Aortic Valve
Fatima, Benish , Khan, Fazal Wahab , Jobanputra, Yash , Tummala, Ramyashree, Krishnaswamy, Amar , Mick, Stephanie, Tuzcu, E. Murat , Svensson, Lars G. , Khan, Fazal W, Mohananey, Divyanshu , Banerjee, Kinjal , Blackstone, Eugene H. , Kapadia, Samir

JAMA Cardiology | December 5, 2018 | Volume: 4 | Issue: 1 | Pages: 71

10.1001/jamacardio.2018.4045 Get It