Background: Hybrid debranching repair of pararenal and thoracoabdominal aortic aneurysms was initially designed as a better alternative to standard open repair, addressing the limitations of endovascular repair involving the visceral aorta. We reviewed the collective outcomes of hybrid debranching repairs using extra-anatomic, open surgical debranching of the renal-mesenteric arteries, followed by endovascular aortic stenting. Methods: Data from patients who underwent hybrid repair in 14 North American institutions during 10 years were retrospectively reviewed. Society of Vascular Surgery scores were used to assess comorbidity risk. Early and late outcomes, including mortality, morbidity, reintervention, and patency were analyzed. Results: A total of 208 patients (118 male; mean age, 71±8 years old) were treated by hybrid repair with extraanatomic reconstruction of 657 renal and mesenteric arteries (mean 3.2 vessels/patient). Mean aneurysm diameter was 6.6±1.3 cm. Thoracoabdominal aortic aneurysms were identified in 163 (78%) patients and pararenal aneurysms in 45 (22%). A single-stage repair was performed in 92 (44%) patients. The iliac arteries were the most common source of inflow (n=132; 63%), and most (n=150; 72%) had 3 or more bypasses. There were 30 (14%) early deaths, ranging widely across sites (0%–21%). A Society of Vascular Surgery comorbidity score >15 was the primary predictor of early mortality ( P <0.01), whereas mortality was 3% in a score ≤9. Early complications occurred in 140 (73%) patients and included respiratory complications in 45 patients (22%) and spinal cord ischemia in 22 (11%), of whom 10 (45%) fully recovered. At 5 years, survival was 61±5%, primary graft patency was 90±2%, and secondary patency was 93±2%. The most significant predictor of late mortality was renal insufficiency ( P <0.0001). Conclusions: Mortality after hybrid repair and visceral debranching is highly variable by center, but strongly affected by preoperative comorbidities and the centers’ experience with the technique. With excellent graft patency at 5 years, the outcomes of hybrid repair done at centers of excellence and in carefully selected patients may be comparable (or better) than traditional open or even totally endovascular approaches. However, in patients already considered as high-risk for surgery, it may not offer better outcomes.
Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.