Barleben, Andrew R.

0000-0003-1586-084X

Mayo Clinic

University of California San Diego

Citations 3

Multicenter Study on Physician-Modified Endografts for Thoracoabdominal and Complex Abdominal Aortic Aneurysm Repair
Tsilimparis, Nikolaos , Melo, Ryan Gouveia e , Scali, Salvatore T. , Mendes, Bernardo C. , Han, Sukgu M. , Schermerhorn, Marc L. , Adam, Donald J., Malas, Mahmoud B. , Starnes, Benjamin W., Branzan, Daniela , Timaran, Carlos H. , Bertoglio, Luca , Pedro, Luís Mendes , Pyun, Alyssa J., Magee, Gregory A. , Swerdlow, Nicholas J. , Juszczak, Maciej , Patel, Rohini J. , Panuccio, Giuseppe , Sweet, Matthew P. , Becquemin, J.-P. , Canonge, Jennifer , Porras-Colón, Jésus , Giordano, Antonino , Gouveia E Melo, Ryan , Tenorio, Emanuel R , Scali, Salvatore , Mendes, Bernardo, Han, Sukgu , Schermerhorn, Marc , Farber, Mark , Kolbel, Tilo , Joseph, George , Branzan, Daniela , H Timaran, Carlos , Cieri, Enrico , Verzini, Fabio , Beck, Adam W , Chait, Jesse , Pyun, Alyssa , Magee, Gregory A , Juszczak, Maciej , Barleben, Andrew R. , Patel, Rohini , Panuccio, Giuseppe , Sweet, Matthew P , Zettervall, Sara L , Becquemin, Jean-Pierre , Canonge, Jennifer , Porras-Colón, Jésus , Dias-Neto, Marina , Giordano, Antonino , Oderich, Gustavo S , Tenorio, Emanuel R. , Kölbel, Tilo , Cochennec, Frédéric , Gomes, Vivian Carla , Dias‐Neto, Marina , Oderich, Gustavo S.

Circulation | July 11, 2024 | Volume: 150 | Issue: 17 | Pages: 1327-1342

10.1161/circulationaha.123.068587 Get It

BACKGROUND: Physician modified endografts (PMEGs) have been widely used in the treatment of complex abdominal aortic aneurysm and thoracoabdominal aortic aneurysm, however, previous data are limited to small single center studies and robust data on safety and effectiveness of PMEGs are lacking. We aimed to perform an international multicenter study analyzing the outcomes of PMEGs in complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. METHODS: An international multicenter single-arm cohort study was performed analyzing the outcomes of PMEGs in the treatment of elective, symptomatic, and ruptured complex abdominal aortic aneurysms and thoracoabdominal aortic aneurysms. Variables and outcomes were defined according to the Society for Vascular Surgery reporting standards. Device modification and procedure details were collected and analyzed. Efficacy outcomes included technical success and safety outcomes included major adverse events and 30-day mortality. Follow-up outcomes included reinterventions, endoleaks, target vessel patency rates and overall and aortic-related mortality. Multivariable analysis was performed aiming at identifying predictors of technical success, 30-day mortality, and major adverse events. RESULTS: Overall, 1274 patients were included in the study from 19 centers. Median age was 74 (IQR, 68–79), and 75.7% were men; 45.7% were complex abdominal aortic aneurysms, and 54.3% were thoracoabdominal aortic aneurysms; 65.5% patients presented electively, 24.6% were symptomatic, and 9.9% were ruptured. Most patients (83.1%) were submitted to a fenestrated repair, 3.6% to branched repair, and 13.4% to a combined fenestrated and branched repair. Most patients (85.8%) had ≥3 target vessels included. The overall technical success was 94% (94% in elective, 93.4% in symptomatic, and 95.1% in ruptured cases). Thirty-day mortality was 5.8% (4.1% in elective, 7.6% in symptomatic, and 12.7% in ruptured aneurysms). Major adverse events occurred in 25.2% of cases (23.1% in elective, 27.8% in symptomatic, and 30.3% in ruptured aneurysms). Median follow-up was 21 months (5.6–50.6). Freedom from reintervention was 73.8%, 61.8%, and 51.4% at 1, 3, and 5 years; primary target vessel patency was 96.9%, 93.6%, and 90.3%. Overall survival and freedom from aortic-related mortality was 82.4%/92.9%, 69.9%/91.6%, and 55.0%/89.1% at 1, 3, and 5 years. CONCLUSIONS: PMEGs were a safe and effective treatment option for elective, symptomatic, and ruptured complex aortic aneurysms. Long-term data and future prospective studies are needed for more robust and detailed analysis.
Pivotal Clinical Study to Evaluate the Safety and Effectiveness of the MANTA Percutaneous Vascular Closure Device
Wood, David , Krajcer, Zvonimir , Sathananthan, Janarthanan , Strickman, Neil E., Metzger, Chris, Fearon, William F. , Aziz, Mark, Satler, Lowell F. , Waksman, Ron , Eng, Marvin H. , Heimansohn, David, Sampson, Andrew, Coady, Paul , Rodriguez, Roberto , Krishnaswamy, Amar , Lee, Jason T. , Ben‐Dor, Itsik , Moainie, Sina L. , Kodali, Susheel , Yadav, Pradeep , Kozak, Mark, Bacharach, J. Michael, Feldman, Ted , Nanjundappa, Aravinda , Bersin, Robert M., Potluri, Srinivasa , Barker, Colin M. , Bernardo, Nelson L. , Lumsden, Alan B. , Dake, Michael D. , Brown, David L. , Maor, Nathaniel, Nardone, Samuel, Webb, John G. , Investigators, on behalf of the SAFE MANTA Study, Kapadia, Samir , Greenbaum, Adam B. , Szerlip, Molly , Chhatriwalla, Adnan K , O’Neill, Brian Patrick , Guerrero, Mayra , Zhang, Ming , Barleben, Andrew R. , Campbell, John , Cohen, David Jonathan , Lauck, Sandra , O’Neill, William W. , Investigators, on behalf of the SAFE MANTA Study

Circulation: Cardiovascular Interventions | July 12, 2019 | Volume: 12 | Issue: 7 | Pages: No page available

10.1161/circinterventions.119.007258 Get It

Background: Open surgical closure and small-bore suture-based preclosure devices have limitations when used for transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or percutaneous thoracic endovascular aortic aneurysm repair. The MANTA vascular closure device is a novel collagen-based technology designed to close large bore arteriotomies created by devices with an outer diameter ranging from 12F to 25F. In this study, we determined the safety and effectiveness of the MANTA vascular closure device. Methods and Results: A prospective, single arm, multicenter investigation in patients undergoing transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, or thoracic endovascular aortic aneurysm repair at 20 sites in North America. The primary outcome was time to hemostasis. The primary safety outcomes were accessed site-related vascular injury or bleeding complications. A total of 341 patients, 78 roll-in, and 263 in the primary analysis cohort, were entered in the study between November 2016 and September 2017. For the primary analysis cohort, transcatheter aortic valve replacement was performed in 210 (79.8%), and percutaneous endovascular abdominal aortic aneurysm repair or thoracic endovascular aortic aneurysm repair was performed in 53 (20.2%). The 14F MANTA was used in 42 cases (16%), and the 18F was used in 221 cases(84%). The mean effective sheath outer diameter was 22F (7.3 mm). The mean time to hemostasis was 65±157 seconds with a median time to hemostasis of 24 seconds. Technical success was achieved in 257 (97.7%) patients, and a single device was deployed in 262 (99.6%) of cases. Valve Academic Research Consortium-2 major vascular complications occurred in 11 (4.2%) cases: 4 received a covered stent (1.5%), 3 had access site bleeding (1.1%), 2 underwent surgical repair (0.8%), and 2 underwent balloon inflation (0.8%). Conclusions: In a selected population, this study demonstrated that the MANTA percutaneous vascular closure device can safely and effectively close large bore arteriotomies created by current generation transcatheter aortic valve replacement, percutaneous endovascular abdominal aortic aneurysm repair, and thoracic endovascular aortic aneurysm repair devices. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT02908880.
Surgical prevention of stroke
Moore, Wesley S. , Brott, Thomas G. , Barleben, Andrew R.

Stroke Management and Recovery | April 10, 2013 | Volume: No volume available | Issue: No issue available | Pages: 100-113