Back to Authors

Kapadia, Samir

https://orcid.org/0000-0002-0026-3391

Mayo Clinic

Cleveland Clinic

Citations 24

Real-World Outcomes of Transcatheter Tricuspid Valve Replacement
Makkar, R R, Gupta, A, O’Neill, Brian P., Lalani, Christina , Sharma, Rahul P., Yadav, Pradeep, Frisoli, Tiberio M., Thourani, Vinod, Eleid, Mackram F., Lee, James, Babaliaros, Vasilis C., Haeffele, Christiane , Bajwa, Tanvir , Flueckiger, Peter, Cubeddu, Robert J., Davidson, Laura J., Padang, Ratnasari , Spinetto, Pedro Villablanca, Narang, Akhil , Williams, Mathew, Gleason, Patrick, Tang, Gilbert H. L., Khera, Sahil , Vavalle, John P., Byku, Isida , Depta, Jeremiah P., Garcia, Santiago, Kapadia, Samir, Zajarías, Alan , Chanin, Jake, Kodali, Susheel K., Herrmann, Howard C., Morse, M. Andrew, Petrossian, George , Sivak, Joseph A. , Hahn, Rebecca T., Song, Yang, Leon, M.B., Yeh, Robert W., Davidson, C, Haeffele, Christiane , Makkar, Raj , Gupta, Aakriti , O’Neill, Brian Patrick , Sharma, Rahul P., Yadav, Pradeep , Frisoli, Tiberio , Thourani, Vinod H. , Makar, Moody M. , Eleid, Mackram F. , Lee, James, Babaliaros, Vasilis , Flueckiger, Peter B. , Davidson, Laura J., Allaqaband, Suhail Q. , Williams, Mathew R., Gleason, Patrick T. , Tang, Gilbert H.L. , Vavalle, John P. , Depta, Jeremiah P , Garcia, Santiago A. , Kapadia, Samir , Kodali, Susheel , Herrmann, Howard C. , Morse, M. Andrew M. , Hahn, Rebecca T , Song, Yang, Yeh, Robert W. , Davidson, Charles J.

JAMA | April 13, 2026 | Volume: 335 | Issue: 18 | Pages: 1606

10.1001/jama.2026.3446 Get It

Importance Transcatheter tricuspid valve replacement (TTVR) demonstrated superior outcomes over medical therapy in patients with severe tricuspid regurgitation (TR) in the Edwards EVOQUE Transcatheter Tricuspid Valve Replacement: Pivotal Clinical Investigation of Safety and Clinical Efficacy Using a Novel Device II (TRISCEND II) randomized clinical trial, and received regulatory approval in the US in 2024. Contemporary real-world data on its effectiveness and safety remain limited. Objective To evaluate 30-day clinical, echocardiographic, and health status outcomes of TTVR in real-world use. Design, Setting, and Population Retrospective cohort study of all consecutive patients who underwent TTVR in the US from February 2024 through March 2025 in the Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry. Patients had symptomatic, severe TR despite optimal medical therapy and TTVR was deemed appropriate by a heart team. Statistical analysis was conducted from September 2025 to February 2026. Exposure Device-enabled TTVR. Main Outcomes and Measures Thirty-day event rates (all-cause death, stroke, bleeding, new cardiac implantable electronic device [CIED] implantation, heart failure hospitalizations), TR reduction, and changes in health status (New York Heart Association [NYHA] functional class and Kansas City Cardiomyopathy Questionnaire Overall Summary [KCCQ-OS] score) are reported. Subgroup analyses examined the impact of baseline CIED status on outcomes. Results Among 1034 attempted procedures at 82 centers (mean [SD] age, 77.1 [10.6] years; 69.1% female; 73.2% NYHA functional class III/IV), a valve was successfully implanted in 1017 patients (98.4%). Mild or less TR was achieved in 98.4% of patients post procedure and in 97.7% at 30 days. At 30 days, all-cause mortality was 3.1%; stroke, 0.2%; bleeding, 7.9%; new CIED, 15.9% in CIED-naive patients; and heart failure hospitalization, 3.1%. There were significant improvements in NYHA functional class (class I/II, 82.7%; P < .001) and mean KCCQ-OS score (22.4 points; P < .001) from baseline to 30 days. There were no significant differences in 30-day mortality ( P = .47), heart failure hospitalization ( P > .99), and functional outcomes ( P = .55) when patients were stratified by baseline CIED status. Conclusions and Relevance Early US real-world experience with TTVR confirms safety and effectiveness in patients with severe TR. Thirty-day outcomes are consistent with the TRISCEND II pivotal trial, demonstrating acceptable safety, near-complete TR elimination, and significant health status improvements in an older, comorbid population. Rates of new CIED implantation and bleeding were lower than randomized clinical trial experience.
Tricuspid valve replacement outcomes by baseline tricuspid regurgitation severity: the TRISCEND II trial
Lurz, Philipp , Hahn, Rebecca T. , Kodali, Susheel , Makkar, Raj , Sharma, Rahul , Davidson, Charles J. , O’Neill, Brian , Yadav, Pradeep , Zahr, Firas , Chadderdon, Scott , Eleid, Mackram F. , Smith, Robert L, Garcia, Santiago , Kister, Tobias , Kipperman, Robert, Lim, Scott, Hermiller, James, Mishell, Jacob M. , Rassi, Andrew N., Szeto, Wilson Y. , Babaliaros, Vasilis , Barker, Colin M. , Summers, Matthew , Chetcuti, Stanley, Ailawadi, Gorav , Russo, Mark, Rinaldi, Michael, Chehab, Bassem , Nickenig, Georg, Stinis, Curtiss, Inglessis‐Azuaje, Ignacio , Dhoble, Abhijeet , Petrossian, George , Shah, Pinak, Staniloae, Cezar , Nores, Marcos, Singh, Gagan D. , Baldus, Stephan , Rudolph, Volker , Barb, Ilie, Klodell, C.T., Gray, William A. , Strote, Justin A, Sannino, Anna , Grayburn, Paul , Mack, Michael J. , Leon, Martin B. , Thourani, Vinod H. , Lim, D. Scott , Szerlip, Molly , Kister, Tobias , Lim, D Scott , Saxon, John , Kapadia, Samir , Mishell, Jacob M , Herrmann, Howard C , Hausleiter, Jörg , Babaliaros, Vasilis , Barker, Colin M , Lindman, Brian R , Latib, Azeem , von Bardeleben, Ralph Stephan , Summers, Matthew , Ailawadi, Gorav , Rinaldi, Michael , Chehab, Bassem M , Nickenig, Georg , Inglessis-Azuaje, Ignacio , Dhoble, Abhijeet , Chhatriwalla, Adnan K , Petrossian, George , Shah, Pinak , Staniloae, Cezar , Williams, Mathew , McCabe, James M , Singh, Gagan , Baldus, Stephan , Rudolph, Volker , Klodell, Charles , Gray, William , Strote, Justin , Sannino, Anna , Grayburn, Paul , Mack, Michael J , Thourani, Vinod H , Davidson, Charles J. , Hahn, Rebecca T , Lurz, Philipp , Smith, Robert L, Whisenant, Brian K. , Kapadia, Samir , Hausleiter, Jörg , Lindman, Brian R. , Latib, Azeem , Muhammad, Kamran I. , Williams, Mathew

European Heart Journal | August 21, 2025 | Volume: 47 | Issue: 17 | Pages: 2059-2073

10.1093/eurheartj/ehaf676 Get It

Abstract Background and Aims The TRISCEND II trial demonstrated superior clinical benefits for patients with ≥severe tricuspid regurgitation (TR) treated with the EVOQUE transcatheter tricuspid valve replacement (TTVR) system plus medical therapy vs medical therapy alone. This work reports 1-year and 18-month outcomes in patients stratified by baseline TR severity. Methods The multicentre, prospective TRISCEND II trial enrolled 400 patients with symptomatic, ≥severe TR, and randomized 2:1 to TTVR (n = 267) or control (n = 133). In a post hoc analysis, patients were stratified into severe TR (n = 172) and massive/torrential TR (n = 220) cohorts. Clinical and quality-of-life outcomes were reported at 1 year, with Kaplan–Meier estimates for all-cause mortality and heart failure (HF) hospitalization assessed at 18 months. Study oversight included an independent echocardiographic core laboratory, clinical events committee, and data safety monitoring board. Results One year after TTVR, TR was ≤mild in 95.2% of severe TR and 95.3% of massive/torrential TR patients. The primary safety and effectiveness endpoint (win ratio) favoured TTVR over control regardless of baseline TR severity: severe {1.64 [95% confidence interval (CI): 1.11, 2.43]} and massive/torrential [2.20 (1.55, 3.14)]. At 18 months, TTVR patients had similar mortality to controls [rate difference: severe 0.2% (−11.6, 11.9), massive/torrential −5.8% (−17.6, 6.0)], whereas HF hospitalization rates favoured TTVR in the massive/torrential cohort [vs control, severe 9.8% (−3.0, 22.7), massive/torrential -15.2% (−28.9, −1.5)]. Conclusions Patients with ≥severe TR benefit from TTVR, experiencing improvements in TR severity, functional capacity, and quality of life regardless of baseline TR severity, with a signal for greater benefit in patients with more advanced disease.
Management of Acute Decompensated Valvular Heart Disease
Lüsebrink, Enzo , Lanz, Hugo, Kellnar, Antonia , Karam, Nicole , Makkar, Raj, Abraham, William T. , Leon, Martin B. , Sannino, Anna , Shuvy, Mony , Guerrero, Mayra , Fam, Neil , Butler, Javed, Adamo, Marianna, Rudolph, Volker , Tang, Gilbert , Rommel, Karl-Philipp , Thiele, Holger , Maßberg, Steffen , Prendergast, Bernard, Hausleiter, Jörg , Hausleiter, Jörg , Sannino, Anna , Kapadia, Samir , Makkar, Raj , Latib, Azeem , Guerrero, Mayra , Adamo, Marianna , Stocker, Thomas J. , Lurz, Philipp , Praz, Fabien

European Journal of Heart Failure | December 12, 2024 | Volume: 27 | Issue: 4 | Pages: 630-649

10.1002/ejhf.3549 Get It

Abstract Worldwide, valvular heart disease (VHD) is a common cause of hospitalization for acute heart failure. In acute heart failure caused by VHD, symptoms result from rapid haemodynamic changes and subsequent decline in cardiac function, and if left untreated, leads to acute decompensation and cardiogenic shock. Current evidence remains scarce and recommendations regarding the management of acute heart failure caused by VHD are lacking in most recent international guidelines. Herein, we review the management of acute heart failure caused by VHD with a focus on transcatheter therapies and describe currently available evidence based on a systematic literature search on the following valve pathologies: (i) aortic stenosis, (ii) aortic regurgitation, (iii) mitral regurgitation, and (iv) mitral stenosis. Articles reporting outcomes following urgent or emergent valve intervention in the setting of cardiogenic shock or acute heart failure were considered. After screening a total of 2234 articles, 76 published between 1994 and 2023 were included in subsequent analysis. Based on available evidence, proposed treatment algorithms to guide optimal management of acute heart failure caused by VHD were created. As the number of patients presenting with acute heart failure caused by VHD continues to rise and outcomes following transcatheter valve interventions continue to improve, it is inevitable that minimally invasive options will play an increasingly important role in the acute setting, especially given these patients are at an increased operative risk. This review aims to present an organized approach to the complex management and interventional treatment of patients with acute heart failure caused by VHD.
Contemporary Outcomes of TAVR Using a Balloon-Expandable Valve in Patients With Severe Mitral Stenosis: Insights From the Transcatheter Valve Therapies Registry
Ahmad, Imran, Flaherty, James D. , Nagaraja, Vinayak , Huded, Chetan , Reed, Grant W. , Puri, Rishi , Rassi, Andrew N., Goel, Sachin S. , Jneid, Hani , Zahr, Firas , Krishnaswamy, Amar , Kumar, Anirudh , Flaherty, James D , Nagaraja, Vinayak , Huded, Chetan P , Reed, Grant W , Puri, Rishi , Goel, Sachin S , Jneid, Hani , McCabe, James M , Guerrero, Mayra E , Zahr, Firas , Krishnaswamy, Amar , Kapadia, Samir , Ahmad, Imran N., Guerrero, Mayra , Kapadia, Samir

Circulation: Cardiovascular Interventions | November 22, 2024 | Volume: 17 | Issue: 12 | Pages: No page available

10.1161/circinterventions.124.014216 Get It

BACKGROUND: While initial data for transcatheter aortic valve replacement (TAVR) in aortic stenosis patients with mitral stenosis (MS) suggested a poor short-term prognosis, outcomes for contemporary balloon-expandable valves remain unknown. The aim of this retrospective multicenter registry study was to compare the potential impact of MS on TAVR outcomes with balloon-expandable valves. METHODS: Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry and Centers for Medicare & Medicaid Services claims data were used to obtain a cohort of 327 925 patients who underwent TAVR with current balloon-expandable valves (SAPIEN 3, SAPIEN 3 Ultra, or SAPIEN 3 Ultra Resilia) between June 2015 and December 2022 across 791 sites. Severe MS (defined as >10 mm Hg mean gradient or <1.5 cm 2 area) was compared with mild or less MS (defined as <5 mm Hg mean gradient and >2 cm 2 area) using propensity matching to minimize confounding variables. RESULTS: Patients with severe MS (n=8500; 2.6%) had a higher number of comorbid conditions, Society of Thoracic Surgeons risk scores, and were more often women than patients with mild or less MS at the time of index TAVR. While patients with severe MS had worse outcomes at 30 days, when propensity-matched, patients exhibited similar 30-day rates of death (3.2% versus 3.0%), stroke (2.4% versus 2.2%), major vascular complications (1.6% versus 1.6%), device implant success (98.9% versus 99.2%), and new dialysis (0.7% versus 0.5%), with higher rates of pacemaker implantation (11.3% versus 9.4%; P <0.001). By 1 year, there was no difference in the change in the KCCQ (Kansas City Cardiomyopathy Questionnaire) overall score from baseline to 1 year (30.7±27.0 versus 31.9±27.0; P =0.07). By 3 years, an increase in the mortality rate (45.1% versus 40.9%; P <0.001) of patients with severe MS was observed. CONCLUSIONS: MS in isolation is not associated with worsened short-term outcomes among patients undergoing contemporary TAVR with balloon-expandable valves.
Contemporary Outcomes and Trends for the Transseptal Mitral Valve-in-Valve Procedure Using Balloon Expandable Transcatheter Valves in the United States
Goel, Kashish , Makkar, Raj , Krishnaswamy, Amar , Kapadia, Samir , Kodali, Susheel , Shah, Ashish S. , Barker, Colin M. , Xu, Ke , Dhoble, Abhijeet , Yadav, Pradeep , Rihal, Charanjit S. , Abbas, Amr E. , Kapadia, Samir , Guerrero, Mayra E , Whisenant, Brian K. , Rihal, Charanjit S. , Guerrero, Mayra

Circulation | August 5, 2024 | Volume: 150 | Issue: 19 | Pages: 1493-1504

10.1161/circulationaha.124.068847 Get It

BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean±SD STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year ( P <0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4–8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital ( P =0.0005), 30-day ( P =0.004), and 1-year mortality rates ( P =0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, acceptable 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.
Abstract 18185: Regression of Severe Left Ventricular Hypertrophy After Transcatheter Valve Replacement for Aortic Stenosis: Impact on Clinical Outcomes in PARTNER Cohort A
Stewart, William C. , Weissman, Neil J., McAndrew, Thomas , Szeto, Wilson Y, Makkar, Raj , Babaliaros, Vasilis , Bowers, Bruce, Greason, Kevin L. , Leon, Martin B, Devereux, Richard B, Lindman, Brian R. , Stewart, William, Pibarot, Phillippe , Hahn, Rebecca T , Szeto, Wilson Y, Miller, D. Craig , Kapadia, Samir , Leon, Martin B, Enriquez‐Sarano, Maurice , Devereux, Richard B, Otto, Catherine M , Douglas, Pamela S.

Circulation | April 23, 2024 | Volume: 128 | Issue: suppl_22 | Pages: No page available

10.1161/circ.128.suppl_22.a18185 Get It

Background: Left ventricular (LV) mass regression after aortic valve replacement (AVR) for aortic stenosis (AS) is a favorable effect of LV unloading, but its relationship to improved clinical outcomes is unclear. We examined the effect on clinical outcomes after transcatheter AVR (TAVR) of: 1) amount of LV mass index (LVMi) regression; and 2) persistent severe LV hypertrophy (LVH). Methods: Of 2115 patients with symptomatic AS at high surgical risk receiving TAVR in the PARTNER randomized trial or continued access registry, 462 (55% women) who had severe LVH (LVMi ≥149 g/m 2 men, ≥122 g/m 2 women, by ASE criteria) at baseline (BL) and LVMi measured 6 mo post-TAVR were included in our analysis. The effect of LVMi regression was evaluated by comparing outcomes in patients with greater vs. lesser decrease (dichotomized by median % change) in LVMi between BL and 6 mo, and in those without vs. with persistent severe LVH 6 mo post-TAVR. Cox PH models evaluated rates of all-cause mortality (6-12 mo), rehospitalizations (through 1 yr), and the composite of these two outcomes. Results: LVMi decreased from 173±32 (BL) to 121±25 g/m 2 (6 mo) (p<0.001) in those with greater LVMi regression, and from 164±30 (BL) to 158±34 g/m 2 (6 mo) (p<0.001) in those with lesser LVMi regression. Patients with greater vs. lesser LVMi regression had similar baseline clinical characteristics, a lower rate of rehospitalization (10.5% vs. 19.9%, p=0.006) and lower rate of the composite endpoint of death or rehospitalization (13.2% vs. 21.4%, p=0.02), but a similar rate of death (4.9% vs. 4.8%, p=0.86). Persistent severe LVH at 6 mo post-TAVR was present in 54% (58% of whom were women). Patients without vs. with persistent severe LVH had similar baseline clinical characteristics, a lower rate of rehospitalization (11.9% vs. 18.1%, p=0.053) and lower rate of the composite endpoint of death or rehospitalization (13.3% vs. 20.7%, p=0.03), but a similar rate of death (3.9% vs. 5.7%, p=0.42). Similar results were obtained when including patients with moderate or severe LVH. Conclusions: In high-risk patients with severe AS and severe LVH undergoing TAVR, greater LV mass regression and resolution of initially severe LVH at 6 months are associated with a lower rate of death or repeat hospitalization.
Atrial Shunt Device Effects on Cardiac Structure and Function in Heart Failure With Preserved Ejection Fraction
Silvestry, Frank E. , Komtebedde, Jan , Solomon, Scott D. , Price, Matthew J. , Kawash, Rami, Hummel, Scott L. , Cutlip, Donald E. , Leon, Martin B. , Veldhuisen, Dirk J. van , Rieth, Andreas , Bugger, Heiko , Mazurek, Jeremy A. , Ky, Bonnie , Ky, Bonnie , Hummel, Scott L , Patel, Ravi B. , Solomon, Scott David , Hasenfuß, Gerd , Litwin, Sheldon E. , Borlaug, Barry A. , McKenzie, Scott , Kapadia, Samir , Vanderheyden, Marc , Shah, Sanjiv J

JAMA Cardiology | April 17, 2024 | Volume: 9 | Issue: 6 | Pages: 507

10.1001/jamacardio.2024.0520 Get It

Importance Although the results of A Study to Evaluate the Corvia Medical Inc IASD System II to Reduce Elevated Left Atrial Pressure in Patients with Heart Failure (REDUCE LAP-HF II) trial were neutral overall, atrial shunt therapy demonstrated potential efficacy in responders (no latent pulmonary vascular disease and no cardiac rhythm management device). Post hoc analyses were conducted to evaluate the effect of shunt vs sham stratified by responder status. Objective To evaluate the effect of atrial shunt vs sham control on cardiac structure/function in the overall study and stratified by responder status. Design, Setting, and Participants This was a sham-controlled randomized clinical trial of an atrial shunt device in heart failure with preserved ejection fraction (HFpEF)/HF with mildly reduced EF (HFmrEF). Trial participants with evaluable echocardiography scans were recruited from 89 international medical centers. Data were analyzed from April 2023 to January 2024. Interventions Atrial shunt device or sham control. Main Outcome Measures Changes in echocardiographic measures from baseline to 1, 6, 12, and 24 months after index procedure. Results The modified intention-to-treat analysis of the REDUCE LAP-HF II trial included 621 randomized patients (median [IQR] age, 72.0 [66.0-77.0] years; 382 female [61.5%]; shunt arm, 309 [49.8%]; sham control arm, 312 [50.2%]). Through 24 months, 212 of 217 patients (98%) in the shunt arm with evaluable echocardiograms had patent shunts. In the overall trial population, the shunt reduced left ventricular (LV) end-diastolic volume (mean difference, −5.65 mL; P &amp;lt;.001), left atrial (LA) minimal volume (mean difference, −2.8 mL; P =.01), and improved LV systolic tissue Doppler velocity (mean difference, 0.69 cm/s; P &amp;lt;.001) and LA emptying fraction (mean difference, 1.88 percentage units; P =.02) compared with sham. Shunt treatment also increased right ventricular (RV; mean difference, 9.58 mL; P &amp;lt;.001) and right atrial (RA; mean difference, 9.71 mL; P &amp;lt;.001) volumes but had no effect on RV systolic function, pulmonary artery pressure, or RA pressure compared with sham. In the shunt arm, responders had smaller increases in RV end-diastolic volume (mean difference, 5.71 mL vs 15.18 mL; interaction P =.01), RV end-systolic volume (mean difference, 1.58 mL vs 7.89 mL; interaction P =.002), and RV/LV ratio (mean difference, 0.07 vs 0.20; interaction P &amp;lt;.001) and larger increases in transmitral A wave velocity (mean difference, 5.08 cm/s vs −1.97 cm/s; interaction P =.02) compared with nonresponders randomized to the shunt, suggesting greater ability to accommodate shunted blood through the pulmonary circulation enabling LA unloading. Conclusions and Relevance In this post hoc analysis of the REDUCE LAP-HF II trial, over 2 years of follow-up, atrial shunting led to reverse remodeling of left-sided chambers and increases in volume of right-sided chambers consistent with the shunt flow but no change in RV systolic function compared with sham. Changes in cardiac structure/function were more favorable in responders compared with nonresponders treated with the shunt, supporting the previously identified responder group hypothesis and mechanism, although further evaluation with longer follow-up is needed. Trial Registration ClinicalTrials.gov Identifier: NCT03088033
Implementing a comprehensive STEMI protocol to improve care metrics and outcomes in patients with in-hospital STEMI: an observational cohort study
Kanaan, Christopher , Kassis, Nicholas , Kravitz, Kathleen, Reed, Grant W. , Krishnaswamy, Amar , Puri, Rishi , Nair, Ravi, Khot, Umesh N. , Kanaan, Christopher N , Kumar, Anirudh , Reed, Grant W , Nair, Raunak Mohan , Huded, Chetan , Lincoff, A. Michael , Khatri, Jaikirshan J , Ziada, Khaled M. , Kapadia, Samir

Open Heart | January 30, 2024 | Volume: 11 | Issue: 1 | Pages: e002505

10.1136/openhrt-2023-002505 Get It

Background Patients who experience in-hospital ST-segment elevation myocardial infarction (iSTEMI) represent a uniquely high-risk cohort owing to delays in diagnosis, prolonged time to reperfusion and increased mortality. Quality initiatives aimed at improving the care of this vulnerable, yet understudied population are needed. Methods This study included consecutive patients with iSTEMI treated with percutaneous coronary intervention (PCI) between 1 January 2011 and 15 July 2019 at a single, tertiary referral centre. A comprehensive iSTEMI protocol (CSP) was implemented on 15 July 2014, incorporating: (1) cardiology fellow activation of the catheterisation lab using standardised criteria, (2) nursing chest pain protocol, (3) improved electronic access to electrocardiographic studies, (4) checklist for initial triage and management, (5) 24/7/365 catheterisation lab readiness and (6) radial-first PCI approach. Key metrics and clinical outcomes were compared before and after CSP implementation. Results Among 125 total subjects, the post-CSP cohort (n=81) was younger, had more males and were more likely to be hospitalised for cardiac-related reasons relative to the pre-CSP cohort (n=44) who were more likely hospitalised for operative-related aetiologies. After CSP adoption, median ECG-to-first-device-activation time decreased from 113 min to 64 min (p<0.001), goal ECG-to-first-device-activation time increased from 36% to 76% of patients (p<0.001), administration of guideline-directed medical therapy prior to PCI increased from 27.3% to 65.4% (p<0.001), trans-radial access increased from 16% to 70% (p<0.001) and rates of discharge home increased from 56.8% to 76.5% (p=0.04). Statistically insignificant numerical reductions were observed post-CSP in in-hospital mortality (18.2% vs 9.9%, p=0.30), 30-day mortality (15.9% vs 12.3%, p=0.78) and 1-year mortality (27.3% vs 21.0%, p=0.57). Conclusions The implementation of a CSP was associated with marked enhancements in key care metrics among patients with iSTEMI. Among a larger cohort, the use of a CSP yielded a significant reduction in ECG-to-first-device-activation time in a particularly vulnerable population at high risk of death.