Contemporary Outcomes and Trends for the Transseptal Mitral Valve-in-Valve Procedure Using Balloon Expandable Transcatheter Valves in the United States
BACKGROUND: Previous transcatheter valve therapy registry analyses of transcatheter mitral valve in valve (MViV) replacement of degenerated bioprosthesis reported early experience in the United States. Given recent increases in transseptal MViV volumes and introduction of the SAPIEN 3 Ultra valve, it is important to determine contemporary outcomes for patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV replacement. METHODS: The Society of Thoracic Surgeons (STS)/American College of Cardiology Transcatheter Valve Therapy Registry was used to extract data for all patients undergoing transseptal SAPIEN 3/SAPIEN 3 Ultra MViV from 2015 to September 2022. Primary efficacy outcome was 1-year all-cause mortality. Secondary end points included 30-day mortality, functional class, quality of life, and mitral valve performance. Primary safety outcomes were device success and in-hospital complications. RESULTS: A total of 4243 patients with a mean±SD STS score of 9.2±7.7 underwent transseptal MViV at 455 sites. The rate of Mitral Valve Academic Research Consortium technical (96.6%) success was high, and procedural complications were low. All-cause in-hospital, 30-day, and 1-year mortality rates were 3.2%, 4.3%, and 13.4%, respectively. Significant improvements in New York Heart Association class (New York Heart Association I/II, 18% to 87%) and quality of life (Kansas City Cardiomyopathy Questionnaire score, 38 to 78) were noted at 1 year ( P <0.0001 for both) after MViV. Upon stratifying by STS scores, it was observed that the low-risk group (STS<4) had a significantly lower in-hospital mortality rate of 0.4%, whereas the intermediate-risk group (STS, 4–8) had an in-hospital mortality rate of 1.9%. From 2015 to 2022, the number of transseptal MViV cases/year increased significantly, whereas procedure times, length of stay, and intensive care unit hours shortened significantly. At the same time, there was a significant trend toward reduced in-hospital ( P =0.0005), 30-day ( P =0.004), and 1-year mortality rates ( P =0.01). CONCLUSIONS: This multicenter, prospective study reports excellent procedural outcomes, acceptable 1-year mortality rates, and a significant improvement in quality of life for patients undergoing transseptal MViV in the contemporary era. Patients in the low-risk and intermediate-risk STS score categories had significantly better outcomes compared with those in the high-risk category. MViV is a reasonable therapy for the majority of patients with degenerated bioprosthetic mitral valves, who are anatomical candidates.
Abstract 18892: Clinical and Hemodynamic Factors Influence the Risk of Pulmonary Hypertension in Patients Undergoing Transcatheter Aortic Valve Replacement: Insights from the PARTNER I Trial and Registry
Introduction: Pulmonary hypertension (PH) is associated with increased mortality after surgical or transcatheter aortic valve replacement (TAVR) for aortic stenosis (AS). Hypothesis: We hypothesized that clinical or hemodynamic factors might influence the relationship between significant PH and increased mortality. Methods: Among patients with symptomatic AS at high or prohibitive surgical risk receiving TAVR in the PARTNER I randomized trial or registry, 2180 patients with an invasive measurement of mean pulmonary artery pressure (mPAP) recorded were included. PH was defined as: none (mPAP<25 mmHg), mild (25 to <35), and mod/sev (≥35). Results: One year all-cause mortality was worse with increasing severity of PH: none (n=785, 18.6%), mild (n=838, 22.7%), and mod/sev (n=557, 25.0%) (p=0.01). The association between mod/sev PH (vs. no PH) and 1y mortality varied by sex and renal function (interaction p=0.03 and p=0.06, respectively). In females, mod/sev PH was associated with increased mortality (24.6% vs. 14.1%, HR 1.89, 95% CI 1.32-2.73); in males it was not (24.9% vs. 22.2%, HR 1.12, 95% CI 0.82-1.52). Additionally, mod/sev PH was associated with mortality in those with glomerular filtration rate (GFR) <40 (HR 1.76, 95% CI 1.28-2.42), but not in those with GFR ≥40. In a multivariable Cox PH model of patients with mod/sev PH, oxygen dependent lung disease, cerebrovascular disease, lower GFR, and lower baseline transvalvular mean gradient were each independently associated with increased 1y mortality (p<0.05 for all), whereas pulmonary artery compliance was the only hemodynamic variable associated with mortality (p=0.043) (Table). Conclusions: The relationship between mod/sev PH and increased mortality after TAVR is altered by sex and renal function. While lower pulmonary artery compliance is associated with increased mortality in patients with significant PH, clinical factors appear to be more influential in stratifying risk than hemodynamic indices.
Sex-Specific Differences at Presentation and Outcomes Among Patients Undergoing Transcatheter Aortic Valve Replacement
Objective Pulmonary hypertension (PH) is associated with increased mortality after surgical or transcatheter aortic valve replacement (TAVR) for aortic stenosis (AS), and when the pulmonary artery pressure is particularly elevated, there may be questions about the clinical benefit of TAVR. We aimed to identify clinical and haemodynamic factors associated with increased mortality after TAVR among those with moderate/severe PH. Methods Among patients with symptomatic AS at high or prohibitive surgical risk receiving TAVR in the Placement of Aortic Transcatheter Valves (PARTNER) I randomised trial or registry, 2180 patients with an invasive measurement of mean pulmonary artery pressure (mPAP) recorded were included, and moderate/severe PH was defined as an mPAP ≥35 mm Hg. Results Increasing severity of PH was associated with progressively worse 1-year all-cause mortality: none (n=785, 18.6%), mild (n=838, 22.7%) and moderate/severe (n=557, 25.0%) (p=0.01). The increased hazard of mortality associated with moderate/severe PH was observed in females, but not males (interaction p=0.03). In adjusted analyses, females with moderate/severe PH had an increased hazard of death at 1 year compared with females without PH (adjusted HR 2.14, 95% CI 1.44 to 3.18), whereas those with mild PH did not. Among males, there was no increased hazard of death associated with any severity of PH. In a multivariable Cox model of patients with moderate/severe PH, oxygen-dependent lung disease, inability to perform a 6 min walk, impaired renal function and lower aortic valve mean gradient were independently associated with increased 1-year mortality (p<0.05 for all), whereas several haemodynamic indices were not. A risk score, including these factors, was able to identify patients with a 15% vs 59% 1-year mortality. Conclusions The relationship between moderate/severe PH and increased mortality after TAVR is altered by sex, and clinical factors appear to be more influential in stratifying risk than haemodynamic indices. These findings may have implications for the evaluation of and treatment decisions for patients referred for TAVR with significant PH. Trial registration NCT00530894.
Cardiopulmonary bypass and intra‐aortic balloon pump use is associated with higher short and long term mortality after transcatheter aortic valve replacement: A PARTNER trial substudy
Background— The objective was to evaluate the effects of aortic annulus size on valve hemodynamics and clinical outcomes in those patients included in the Placement of Aortic Transcatheter Valves (PARTNER) randomized controlled trial cohort A and the nonrandomized continued access cohort. Methods and Results— Patients included the randomized controlled trial (n=574) and nonrandomized continued access (n=1358) cohorts were divided in tertiles according to aortic annulus diameter (small aortic annulus tertile, medium aortic annulus tertile, and large aortic annulus tertile [LAA], respectively) as measured by transthoracic echocardiography. Severe prosthesis–patient mismatch was defined as an effective aortic orifice area of <0.65 cm 2 /m 2 . In the randomized controlled trial cohort, patients in the small aortic annulus tertile who underwent transcatheter aortic valve replacement had a lower incidence of severe prosthesis–patient mismatch (19.7% versus 37.5%; P =0.03) and only a trend toward a higher incidence of moderate-to-severe paravalvular leaks compared with surgical aortic valve replacement (5.7% versus 0%; P =0.06). In the LAA tertile, there were no differences in the rate of prosthesis–patient mismatch between groups, and a significant increase in moderate-to-severe paravalvular leaks was associated with transcatheter aortic valve replacement (9% versus 0%; P =0.01). There were no differences in mortality between transcatheter aortic valve replacement and surgical aortic valve replacement. In the nonrandomized continued access cohort, there were no differences in prosthesis–patient mismatch between the small aortic annulus and LAA tertiles, but a higher rate of moderate-to-severe paravalvular leaks was observed in the LAA tertile (5.9% versus 11.5%; P =0.009). Patients in the LAA tertile had a higher mortality rate at 1-year follow-up ( P =0.02), and differences persisted in multivariable analysis ( P =0.048 for LAA versus medium aortic annulus tertile, P =0.035 for LAA versus small aortic annulus tertile). Conclusions— Aortic annulus size had a major impact on valve hemodynamics and clinical outcomes after transcatheter aortic valve replacement and surgical aortic valve replacement. This study highlights the importance of considering aortic annulus size in the evaluation of high-risk patients who are candidates for aortic valve replacement. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.