Back to Authors

Williams, Mathew

0000-0003-2055-8741

Mayo Clinic

Department of Cardiothoracic Surgery, New York University Langone Medical Center, New York, NY, USA.

Citations 4

Tricuspid valve replacement outcomes by baseline tricuspid regurgitation severity: the TRISCEND II trial
Lurz, Philipp , Hahn, Rebecca T. , Kodali, Susheel , Makkar, Raj , Sharma, Rahul , Davidson, Charles J. , O’Neill, Brian , Yadav, Pradeep , Zahr, Firas , Chadderdon, Scott , Eleid, Mackram F. , Smith, Robert L, Garcia, Santiago , Kister, Tobias , Kipperman, Robert, Lim, Scott, Hermiller, James, Mishell, Jacob M. , Rassi, Andrew N., Szeto, Wilson Y. , Babaliaros, Vasilis , Barker, Colin M. , Summers, Matthew , Chetcuti, Stanley, Ailawadi, Gorav , Russo, Mark, Rinaldi, Michael, Chehab, Bassem , Nickenig, Georg, Stinis, Curtiss, Inglessis‐Azuaje, Ignacio , Dhoble, Abhijeet , Petrossian, George , Shah, Pinak, Staniloae, Cezar , Nores, Marcos, Singh, Gagan D. , Baldus, Stephan , Rudolph, Volker , Barb, Ilie, Klodell, C.T., Gray, William A. , Strote, Justin A, Sannino, Anna , Grayburn, Paul , Mack, Michael J. , Leon, Martin B. , Thourani, Vinod H. , Lim, D. Scott , Szerlip, Molly , Kister, Tobias , Lim, D Scott , Saxon, John , Kapadia, Samir , Mishell, Jacob M , Herrmann, Howard C , Hausleiter, Jörg , Babaliaros, Vasilis , Barker, Colin M , Lindman, Brian R , Latib, Azeem , von Bardeleben, Ralph Stephan , Summers, Matthew , Ailawadi, Gorav , Rinaldi, Michael , Chehab, Bassem M , Nickenig, Georg , Inglessis-Azuaje, Ignacio , Dhoble, Abhijeet , Chhatriwalla, Adnan K , Petrossian, George , Shah, Pinak , Staniloae, Cezar , Williams, Mathew , McCabe, James M , Singh, Gagan , Baldus, Stephan , Rudolph, Volker , Klodell, Charles , Gray, William , Strote, Justin , Sannino, Anna , Grayburn, Paul , Mack, Michael J , Thourani, Vinod H , Davidson, Charles J. , Hahn, Rebecca T , Lurz, Philipp , Smith, Robert L, Whisenant, Brian K. , Kapadia, Samir , Hausleiter, Jörg , Lindman, Brian R. , Latib, Azeem , Muhammad, Kamran I. , Williams, Mathew

European Heart Journal | August 21, 2025 | Volume: 47 | Issue: 17 | Pages: 2059-2073

10.1093/eurheartj/ehaf676 Get It

Abstract Background and Aims The TRISCEND II trial demonstrated superior clinical benefits for patients with ≥severe tricuspid regurgitation (TR) treated with the EVOQUE transcatheter tricuspid valve replacement (TTVR) system plus medical therapy vs medical therapy alone. This work reports 1-year and 18-month outcomes in patients stratified by baseline TR severity. Methods The multicentre, prospective TRISCEND II trial enrolled 400 patients with symptomatic, ≥severe TR, and randomized 2:1 to TTVR (n = 267) or control (n = 133). In a post hoc analysis, patients were stratified into severe TR (n = 172) and massive/torrential TR (n = 220) cohorts. Clinical and quality-of-life outcomes were reported at 1 year, with Kaplan–Meier estimates for all-cause mortality and heart failure (HF) hospitalization assessed at 18 months. Study oversight included an independent echocardiographic core laboratory, clinical events committee, and data safety monitoring board. Results One year after TTVR, TR was ≤mild in 95.2% of severe TR and 95.3% of massive/torrential TR patients. The primary safety and effectiveness endpoint (win ratio) favoured TTVR over control regardless of baseline TR severity: severe {1.64 [95% confidence interval (CI): 1.11, 2.43]} and massive/torrential [2.20 (1.55, 3.14)]. At 18 months, TTVR patients had similar mortality to controls [rate difference: severe 0.2% (−11.6, 11.9), massive/torrential −5.8% (−17.6, 6.0)], whereas HF hospitalization rates favoured TTVR in the massive/torrential cohort [vs control, severe 9.8% (−3.0, 22.7), massive/torrential -15.2% (−28.9, −1.5)]. Conclusions Patients with ≥severe TR benefit from TTVR, experiencing improvements in TR severity, functional capacity, and quality of life regardless of baseline TR severity, with a signal for greater benefit in patients with more advanced disease.
Computed Tomography–Based Indexed Aortic Annulus Size to Predict Prosthesis-Patient Mismatch
Head, Stuart J., Reardon, Michael J. , Deeb, G. Michael, Popma, Jeffrey J. , Gleason, Thomas G. , Williams, Mathew , Radhakrishnan, Sam, Oh, Jae K. , Chang, Yanping, Boulware, Michael J., Investigators, for the SURTAVI, Reardon, Michael J , Deeb, G. Michael , Mieghem, Nicolas M. Van , Fremes, Stephen E. , Kappetein, A. Pieter , Investigators, for the SURTAVI, Williams, Mathew

Circulation: Cardiovascular Interventions | April 1, 2019 | Volume: 12 | Issue: 4 | Pages: No page available

10.1161/circinterventions.118.007396 Get It

Background: Hemodynamic performance of prostheses after transcatheter aortic valve replacement (TAVR) is generally better than after surgical aortic valve replacement (SAVR), especially in patients with a small native annulus size. However, it remains unclear whether differences are consistent for patients with a different propensity for developing prosthesis-patient mismatch (PPM), considering annulus size and body size of patients. Methods and Results: The SURTAVI trial (Surgical Replacement and Transcatheter Aortic Implantation) compared TAVR using a self-expandable valve with SAVR in intermediate-risk patients. Multidetector computed tomography–based aortic annulus size consisted of the perimeter-derived diameter, which was divided by body surface area to produce an indexed annulus size. Patients were categorized into a small (9–12 mm/m 2 ), medium (>12–14 mm/m 2 ), and large (>14–18 mm/m 2 ) group according to indexed annulus size. We compared TAVR and SAVR for PPM, hemodynamics, and clinical, and functional outcomes through 1-year follow-up within the size groups. Patients who underwent TAVR received a larger prosthesis with increasing indexed annulus size ( P <0.001), while there was no difference in prosthesis size in patients who underwent SAVR ( P =0.74). Patients in all size groups had significantly larger indexed effective orifice area and lower mean gradients at discharge after TAVR versus SAVR. Rates of PPM were significantly lower with TAVR versus SAVR in all groups ( P <0.001) and declined with larger indexed annulus sizes with both TAVR ( P =0.04) and SAVR ( P =0.03). Indexed annulus size was an independent predictor of PPM after TAVR and SAVR. Clinical outcomes were comparable between TAVR and SAVR across all groups, apart from a significantly higher rate of reintervention after TAVR versus SAVR in the large indexed annulus size group (2.5% versus 0%; P =0.01) but without significant interaction ( P int =0.81). Conclusions: Rates of PPM were significantly lower after TAVR than after SAVR across all groups of indexed annulus size, reflecting better hemodynamic performance of transcatheter versus surgical valves, irrespective of the propensity to develop PPM. More attention should be directed to prevention of PPM after SAVR. This information should be considered by the Heart Team to recommend a specific procedure or valve. Clinical Trial Registration: URL: https://www.clinicaltrials.gov . Unique identifier: NCT01586910.
Sex-Specific Differences at Presentation and Outcomes Among Patients Undergoing Transcatheter Aortic Valve Replacement
Kodali, Susheel , Williams, Mathew , Doshi, Darshan , Hahn, Rebecca T. , Humphries, Karin H. , Douglas, Pamela S. , Mack, Michael J. , Xu, Ke , Svensson, Lars G. , Thourani, Vinod H. , Tuzcu, E. Murat , Weissman, Neil J., Leon, Martin B. , Kirtane, Ajay J. , Hahn, Rebecca T , Nkomo, Vuyisile T. , Cohen, David Jonathan , Douglas, Pamela S , Williams, Mathew

Annals of Internal Medicine | February 22, 2016 | Volume: 164 | Issue: 6 | Pages: 377

10.7326/m15-0121 Get It

Propensity-Matched Comparisons of Clinical Outcomes After Transapical or Transfemoral Transcatheter Aortic Valve Replacement
Suri, Rakesh M. , Rajeswaran, Jeevanantham , Babaliaros, Vasilis , Douglas, Pamela S. , Fearon, William F. , Miller, D. Craig , Kirtane, Ajay J. , Kodali, Susheel , Mack, Michael J. , Szeto, Wilson Y. , Thourani, Vinod H. , Tuzcu, E. Murat , Williams, Mathew , Akin, Jodi J., Leon, Martin B. , Svensson, Lars G. , Blackstone, Eugene H. , Mack, Michael, Williams, Mathew R, Hahn, Rebecca T , Kapadia, Samir , Douglas, Pamela S , Williams, Mathew

Circulation | April 2, 2015 | Volume: 131 | Issue: 22 | Pages: 1989-2000

10.1161/circulationaha.114.012525 Get It

Background— The higher risk of adverse outcomes after transapical (TA) versus transfemoral (TF) transcatheter aortic valve replacement (TAVR) could be attributable to TA-TAVR being an open surgical procedure or to clinical differences between TA- and TF-TAVR patients. We compared outcomes after neutralizing patient differences using propensity score matching. Methods and Results— From April 2007 to February 2012, 1100 Placement of Aortic Transcatheter Valves (PARTNER)-I patients underwent TA-TAVR and 1521 underwent TF-TAVR with Edwards SAPIEN balloon-expandable bioprostheses. Propensity matching based on 111 preprocedural variables, exclusive of femoral access morphology, identified 501 well-matched patient pairs (46% of possible matches), 95% of whom had peripheral arterial disease. Matched TA-TAVR patients experienced more adverse procedural events, longer length of stay (5 versus 8 days; P <0.0001), and slower recovery (New York Heart Association class I, 31% versus 38% at 30 days, equalizing by 6 months at 51% versus 47%); stroke risk was similar (3.4% versus 3.3% at 30 days and 6.0% versus 6.7% at 3 years); mortality was elevated for the first 6 postprocedural months (19% versus 12%; P =0.01); but aortic regurgitation was less (34% versus 52% mild and 8.9% versus 12% moderate to severe at discharge, P =0.001; 36% versus 50% mild and 10% versus 15% moderate to severe at 6 months, P <0.0001). Conclusions— The likelihood of adverse periprocedural events and prolonged recovery is greater after TA-TAVR than TF-TAVR in vasculopathic patients after accounting for differences in cardiovascular risk factors, although stroke risk is equivalent and aortic regurgitation is less. As smaller delivery systems permit TF-TAVR in many of these patients, we recommend a TF-first access strategy for TAVR when anatomically feasible. Clinical Trial Registration— URL: http://www.clinicaltrials.gov . Unique identifier: NCT00530894.