Back to Authors

Lincoff, A. Michael

https://orcid.org/0000-0001-8175-2121

Mayo Clinic

Cleveland Clinic

Citations 6

Implementing a comprehensive STEMI protocol to improve care metrics and outcomes in patients with in-hospital STEMI: an observational cohort study
Kanaan, Christopher , Kassis, Nicholas , Kravitz, Kathleen, Reed, Grant W. , Krishnaswamy, Amar , Puri, Rishi , Nair, Ravi, Khot, Umesh N. , Kanaan, Christopher N , Kumar, Anirudh , Reed, Grant W , Nair, Raunak Mohan , Huded, Chetan , Lincoff, A. Michael , Khatri, Jaikirshan J , Ziada, Khaled M. , Kapadia, Samir

Open Heart | January 30, 2024 | Volume: 11 | Issue: 1 | Pages: e002505

10.1136/openhrt-2023-002505 Get It

Background Patients who experience in-hospital ST-segment elevation myocardial infarction (iSTEMI) represent a uniquely high-risk cohort owing to delays in diagnosis, prolonged time to reperfusion and increased mortality. Quality initiatives aimed at improving the care of this vulnerable, yet understudied population are needed. Methods This study included consecutive patients with iSTEMI treated with percutaneous coronary intervention (PCI) between 1 January 2011 and 15 July 2019 at a single, tertiary referral centre. A comprehensive iSTEMI protocol (CSP) was implemented on 15 July 2014, incorporating: (1) cardiology fellow activation of the catheterisation lab using standardised criteria, (2) nursing chest pain protocol, (3) improved electronic access to electrocardiographic studies, (4) checklist for initial triage and management, (5) 24/7/365 catheterisation lab readiness and (6) radial-first PCI approach. Key metrics and clinical outcomes were compared before and after CSP implementation. Results Among 125 total subjects, the post-CSP cohort (n=81) was younger, had more males and were more likely to be hospitalised for cardiac-related reasons relative to the pre-CSP cohort (n=44) who were more likely hospitalised for operative-related aetiologies. After CSP adoption, median ECG-to-first-device-activation time decreased from 113 min to 64 min (p<0.001), goal ECG-to-first-device-activation time increased from 36% to 76% of patients (p<0.001), administration of guideline-directed medical therapy prior to PCI increased from 27.3% to 65.4% (p<0.001), trans-radial access increased from 16% to 70% (p<0.001) and rates of discharge home increased from 56.8% to 76.5% (p=0.04). Statistically insignificant numerical reductions were observed post-CSP in in-hospital mortality (18.2% vs 9.9%, p=0.30), 30-day mortality (15.9% vs 12.3%, p=0.78) and 1-year mortality (27.3% vs 21.0%, p=0.57). Conclusions The implementation of a CSP was associated with marked enhancements in key care metrics among patients with iSTEMI. Among a larger cohort, the use of a CSP yielded a significant reduction in ECG-to-first-device-activation time in a particularly vulnerable population at high risk of death.
Prediction of 1‐year mortality and impact of bivalirudin therapy according to level of baseline risk: A patient‐level pooled analysis from three randomized trials
Yu, Jennifer , Clayton, Tim , Brodie, Bruce R. , Witzenbichler, Bernhard , Deliargyris, Efthymios , Pocock, Stuart , Stone, Gregg W. , Dangas, George , Mehran, Roxana , Gibson, C. Michael , Lincoff, A. Michael , Gersh, Bernard J.

Catheterization and Cardiovascular Interventions | December 1, 2015 | Volume: 87 | Issue: 3 | Pages: 391-400

10.1002/ccd.26146 Get It

Objectives: We aimed to construct a predictive model for one‐year mortality in patients undergoing invasive coronary evaluation and to examine the impact of bivalirudin on survival according to the level of baseline risk.Background: Compared to heparin plus GP IIb/IIIa inhibitors (HEP/GPI), bivalirudin decreases bleeding complications in a range of clinical presentations. The impact of preprocedural risk assessment on survival and whether this is modified by bivalirudin, has not been investigated in detail.Methods: We examined patient‐level data from the REPLACE‐2, ACUITY, and HORIZONS‐AMI trials (n = 18,819) to construct a risk‐adjusted mortality model using baseline clinical variables.Results: One‐year mortality occurred in 287 patients (3.1%) assigned to bivalirudin and 336 patients (3.6%) assigned to HEP/GPI (HR 0.85; 95% CI, 0.73–1.00; P = 0.048). Using 11 highly significant predictors of mortality, we developed an integer‐risk score to classify patients into risk tertiles. High‐risk patients had a rate of 1‐year mortality over 9‐fold greater than low‐risk patients. Consequently, the absolute mortality reduction attributed to bivalirudin was more marked in high‐risk patients: 3.1% (−0.8% to 7.0%) in the overall cohort, 4.8% (0.5% to 9.2%) in the PCI cohort (P‐interaction versus intermediate and low risk categories, 0.09 and P = 0.02, respectively).Conclusions: In patients undergoing invasive coronary evaluation, 1‐year mortality can be predicted using baseline variables. Bivalirudin treatment (versus HEP/GPI) conferred a survival benefit. © 2015 Wiley Periodicals, Inc.
Management of Patients With Acute Coronary Syndromes in the United States by Platelet Glycoprotein IIb/IIIa Inhibition
Harrington, Robert A. , Guerci, Alan D., Ohman, E. Magnus , Kopecky, Steven L., Kleiman, Neal S. , Pacchiana, Cynthia M., Berdan, Lisa G. , Kitt, Michael M., Simoons, Maarten L. , Lincoff, A. Michael , Califf, Robert M. , Hochman, Judith S. , Pepine, Carl J. , Topol, Eric J.

Circulation | June 12, 2012 | Volume: 102 | Issue: 10 | Pages: 1093-1100

10.1161/01.cir.102.10.1093 Get It

Background —A multinational, randomized, placebo-controlled trial (Platelet Glycoprotein IIb/IIIa in Unstable Angina: Receptor Suppression Using Integrilin Therapy, PURSUIT) demonstrated that the platelet glycoprotein IIb/IIIa receptor antagonist eptifibatide reduced the incidence of death or myocardial infarction among patients with acute ischemic syndromes without ST-segment elevation. Because of expected differences in practice patterns, a prospectively planned analysis of outcomes as a function of regions of the world was performed. The current study provides a detailed assessment of eptifibatide among the subgroup of patients enrolled within the United States. Methods and Results —Patients presenting with chest pain within the previous 24 hours and ischemic ECG changes or creatine kinase–MB elevation were eligible for enrollment. Of the 10 948 patients randomized worldwide, 4035 were enrolled within the United States. Patients were allocated to placebo or eptifibatide infusion for up to 72 to 96 hours. Other medical therapies and revascularization strategies were at the discretion of the treating physician. Eptifibatide reduced the rate of the primary end point of death or myocardial infarction by 30 days from 15.4% to 11.9% ( P =0.003) among patients in the United States. The treatment effect was achieved early and maintained over a period of 6 months (18.9% versus 15.2%; P =0.004). Bleeding events were more common in patients receiving eptifibatide but were predominantly associated with invasive procedures. The magnitude of clinical benefit from eptifibatide was greater among patients in the United States than elsewhere in the world. Conclusions —Platelet glycoprotein IIb/IIIa receptor blockade with eptifibatide reduces the incidence of death or myocardial infarction among patients treated for acute ischemic syndromes without ST-segment elevation within the United States.
Marked Inflammatory Sequelae to Implantation of Biodegradable and Nonbiodegradable Polymers in Porcine Coronary Arteries
Giessen, Willem J. van der, Schwartz, Robert S., Beusekom, Heleen M.M. van , Holmes, David R. , Ellis, Stephen G. , Lincoff, A. Michael , Serruys, Patrick W. , Topol, Eric J.

Circulation | June 12, 2012 | Volume: 94 | Issue: 7 | Pages: 1690-1697

10.1161/01.cir.94.7.1690 Get It

Background With the thrombogenic tendency and permanent implant nature of metallic stents, synthetic polymers have been proposed as candidate materials for stents and local drug delivery designs. We investigated the biocompatibility of several synthetic polymers after experimental placement in the coronary artery. Methods and Results Five different biodegradable polymers (polyglycolic acid/polylactic acid [PGLA], polycaprolactone [PCL], polyhydroxybutyrate valerate [PHBV], polyorthoester [POE], and polyethyleneoxide/polybutylene terephthalate [PEO/PBTP]) and three nonbiodegradable polymers (polyurethane [PUR], silicone [SIL], and polyethylene terephthalate [PETP]) were tested as strips deployed longitudinally across 90° of the circumferential surface of coil wire stents. Appropriately sized polymer-loaded stents were implanted in porcine coronary arteries of 2.5- to 3.0-mm diameter. Four weeks after implantation, stent patency was assessed by angiography followed by microscopic examination of the coronary arteries. The biodegradable PCL, PHBV, and POE and the nonbiodegradable PUR and SIL evoked extensive inflammatory responses and fibrocellular proliferation (thickness of tissue response: 0.79±0.22, 1.12±0.01, 2.36±0.60, 1.24±0.36, and 1.43±0.15 mm, respectively). Less but still severe responses were observed for the biodegradable PGLA and PEO/PBTP (0.46±0.18 and 0.61±0.23 mm, respectively) and for the nonbiodegradable PETP (0.46±0.11 mm). Conclusions An array of both biodegradable and nonbiodegradable polymers has been demonstrated to induce a marked inflammatory reaction within the coronary artery with subsequent neointimal thickening, which was not expected on the basis of in vitro tests. The observed tissue response may be attributable to a combination of parent polymer compound, biodegradation products, and possibly implant geometry.
Results of Prevention of REStenosis with Tranilast and its Outcomes (PRESTO) Trial
Holmes, David R. , Lablanche, J M, Grip, Lars, Serruys, P. W., Fitzgerald, Peter J., Goldberg, Sheldon, Brinker, Jeffrey, Zeiher, Andreas M. , Shapiro, Leonard M., Willerson, James T., Davis, Barry R. , Ferguson, James J., Popma, Jeffrey J. , King, Spencer B., Tcheng, James E. , Chan, Robert , Granett, Jeffrey R., Poland, Marcia, Savage, Michael P. , Fischman, David L. , Lincoff, A. Michael

Circulation | September 3, 2002 | Volume: 106 | Issue: 10 | Pages: 1243-1250

10.1161/01.cir.0000028335.31300.da Get It

Background— Restenosis after percutaneous coronary intervention (PCI) is a major problem affecting 15% to 30% of patients after stent placement. No oral agent has shown a beneficial effect on restenosis or on associated major adverse cardiovascular events. In limited trials, the oral agent tranilast has been shown to decrease the frequency of angiographic restenosis after PCI. Methods and Results— In this double-blind, randomized, placebo-controlled trial of tranilast (300 and 450 mg BID for 1 or 3 months), 11 484 patients were enrolled. Enrollment and drug were initiated within 4 hours after successful PCI of at least 1 vessel. The primary end point was the first occurrence of death, myocardial infarction, or ischemia-driven target vessel revascularization within 9 months and was 15.8% in the placebo group and 15.5% to 16.1% in the tranilast groups ( P =0.77 to 0.81). Myocardial infarction was the only component of major adverse cardiovascular events to show some evidence of a reduction with tranilast (450 mg BID for 3 months): 1.1% versus 1.8% with placebo ( P =0.061 for intent-to-treat population). The primary reason for not completing treatment was ≥1 hepatic laboratory test abnormality (11.4% versus 0.2% with placebo, P <0.01). In the angiographic substudy composed of 2018 patients, minimal lumen diameter (MLD) was measured by quantitative coronary angiography. At follow-up, MLD was 1.76±0.77 mm in the placebo group, which was not different from MLD in the tranilast groups (1.72 to 1.78±0.76 to 80 mm, P =0.49 to 0.89). In a subset of these patients (n=1107), intravascular ultrasound was performed at follow-up. Plaque volume was not different between the placebo and tranilast groups (39.3 versus 37.5 to 46.1 mm 3 , respectively; P =0.16 to 0.72). Conclusions— Tranilast does not improve the quantitative measures of restenosis (angiographic and intravascular ultrasound) or its clinical sequelae.