Back to Authors

Beusekom, Heleen M.M. van

https://orcid.org/0000-0002-2930-1152

Mayo Clinic

Erasmus MC

Citations 2

Local endothelial DNA repair deficiency causes aging-resembling endothelial-specific dysfunction
Bautista‐Niño, Paula K. , Portilla-Fernández, Eliana , Rubio‐Beltrán, Eloísa , Linden, Janette J. van der, Vries, René de, Veghel, Richard van , Boer, Martine de , Ridwan, Yanto, Brandt, Renata M. C. , Essers, Jeroen , Thomas, Rachel , Bruin, Alain de , Duncker, Dirk J. , Beusekom, Heleen M.M. van , Ghanbari, Mohsen , Sedláček, Radislav , Pluijm, Ingrid van der , Haanes, Kristian Agmund , Roks, Anton J.M. , Durik, Matej , de Bruin, Alain , Linden, Janette van der , Menzies, Robert I., Hoeijmakers, Jan H.J. , Touyz, Rhian M. , Montezano, Augusto C. , Danser, A.H. Jan

Clinical Science | March 23, 2020 | Volume: 134 | Issue: 7 | Pages: 727-746

10.1042/cs20190124 Get It

Abstract We previously identified genomic instability as a causative factor for vascular aging. In the present study, we determined which vascular aging outcomes are due to local endothelial DNA damage, which was accomplished by genetic removal of ERCC1 (excision repair cross-complementation group 1) DNA repair in mice (EC-knockout (EC-KO) mice). EC-KO showed a progressive decrease in microvascular dilation of the skin, increased microvascular leakage in the kidney, decreased lung perfusion, and increased aortic stiffness compared with wild-type (WT). EC-KO showed expression of DNA damage and potential senescence marker p21 exclusively in the endothelium, as demonstrated in aorta. Also the kidney showed p21-positive cells. Vasodilator responses measured in organ baths were decreased in aorta, iliac and coronary artery EC-KO compared with WT, of which coronary artery was the earliest to be affected. Nitric oxide-mediated endothelium-dependent vasodilation was abolished in aorta and coronary artery, whereas endothelium-derived hyperpolarization and responses to exogenous nitric oxide (NO) were intact. EC-KO showed increased superoxide production compared with WT, as measured in lung tissue, rich in endothelial cells (ECs). Arterial systolic blood pressure (BP) was increased at 3 months, but normal at 5 months, at which age cardiac output (CO) was decreased. Since no further signs of cardiac dysfunction were detected, this decrease might be an adaptation to prevent an increase in BP. In summary, a selective DNA repair defect in the endothelium produces features of age-related endothelial dysfunction, largely attributed to loss of endothelium-derived NO. Increased superoxide generation might contribute to the observed changes affecting end organ perfusion, as demonstrated in kidney and lung.
Marked Inflammatory Sequelae to Implantation of Biodegradable and Nonbiodegradable Polymers in Porcine Coronary Arteries
Giessen, Willem J. van der, Schwartz, Robert S., Beusekom, Heleen M.M. van , Holmes, David R. , Ellis, Stephen G. , Lincoff, A. Michael , Serruys, Patrick W. , Topol, Eric J.

Circulation | June 12, 2012 | Volume: 94 | Issue: 7 | Pages: 1690-1697

10.1161/01.cir.94.7.1690 Get It

Background With the thrombogenic tendency and permanent implant nature of metallic stents, synthetic polymers have been proposed as candidate materials for stents and local drug delivery designs. We investigated the biocompatibility of several synthetic polymers after experimental placement in the coronary artery. Methods and Results Five different biodegradable polymers (polyglycolic acid/polylactic acid [PGLA], polycaprolactone [PCL], polyhydroxybutyrate valerate [PHBV], polyorthoester [POE], and polyethyleneoxide/polybutylene terephthalate [PEO/PBTP]) and three nonbiodegradable polymers (polyurethane [PUR], silicone [SIL], and polyethylene terephthalate [PETP]) were tested as strips deployed longitudinally across 90° of the circumferential surface of coil wire stents. Appropriately sized polymer-loaded stents were implanted in porcine coronary arteries of 2.5- to 3.0-mm diameter. Four weeks after implantation, stent patency was assessed by angiography followed by microscopic examination of the coronary arteries. The biodegradable PCL, PHBV, and POE and the nonbiodegradable PUR and SIL evoked extensive inflammatory responses and fibrocellular proliferation (thickness of tissue response: 0.79±0.22, 1.12±0.01, 2.36±0.60, 1.24±0.36, and 1.43±0.15 mm, respectively). Less but still severe responses were observed for the biodegradable PGLA and PEO/PBTP (0.46±0.18 and 0.61±0.23 mm, respectively) and for the nonbiodegradable PETP (0.46±0.11 mm). Conclusions An array of both biodegradable and nonbiodegradable polymers has been demonstrated to induce a marked inflammatory reaction within the coronary artery with subsequent neointimal thickening, which was not expected on the basis of in vitro tests. The observed tissue response may be attributable to a combination of parent polymer compound, biodegradation products, and possibly implant geometry.