Abstract Introduction Left atrial-to-coronary sinus (LA-to-CS) shunting through the APTURE transcatheter shunt system aims to unload the LA while preserving the interatrial septum. This article aims to examine the 3-year health status, functional capacity, and clinical outcomes of the ALT-FLOW Early Feasibility Study (EFS). Methods Device safety, patency, and echocardiographic parameters, but also symptoms, health status, and exercise capacity were assessed in patients with left ventricular ejection fraction (LVEF) > 40% (n & 95). Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score predicted 3-year all-cause mortality was compared with observed mortality assessed by Kaplan–Meier analysis using adjudicated events. Predicted and observed HF hospitalization (HFH)-free survival rates were also compared. Results At 3 years, the safety profile remained stable with no new safety signals, and all implanted shunts remained patent. 76.3% of patients improved by at least one NYHA class, and mean KCCQ Overall Summary Scores increased by 25 points from baseline (P < .0001). The 6-min walk distance improved by an average of 39 m (P & .002). These benefits were consistent regardless of baseline pulmonary vascular resistance (PVR). Right heart echocardiographic parameters after 3 years were stable, though a reduction in TAPSE was observed, primarily in the high PVR subgroup. The observed 3-year survival was significantly higher than the MAGGIC-predicted survival (84.4% vs 70.2, respectively; P & .009), as well as the HFH-free survival (68.0% vs 24.0%, respectively; P < 0001). Conclusion In patients with HF and LVEF >40%, the APTURE LA-to-CS shunting confirmed an acceptable safety profile with stable right heart parameters and sustained improvements in symptoms, quality of life, and functional capacity at 3 years. Observed survival and HFH were superior to MAGGIC predictions.
Rationale and design of a randomized, sham-controlled, clinical trial for evaluation of the Edwards APTURE transcatheter shunt system (ALT-FLOW II)
Abstract Aims Heart failure (HF) with preserved (HFpEF) and mildly reduced (HFmrEF) ejection fraction are prevalent, yet frequently underdiagnosed syndromes associated with high morbidity and mortality, impaired quality of life, and escalating healthcare expenditures. Although guideline-directed medications like SGLT2 inhibitors have been shown to reduce the risk of hospitalization and cardiovascular death, their use remains limited and substantial residual risk persists. This trial aims to evaluate the safety and performance of a novel left-atrium-to-coronary-sinus shunt (Edwards APTURE transcatheter shunt system) in HFpEF and HFmrEF patients. Methods ALT-FLOW II is a prospective multi-centre, randomized, sham-controlled, double-blinded (patient and assessor) trial. Approximately 100 symptomatic HF patients aged ≥18 years with left ventricular ejection fraction >40% and exercise pulmonary capillary wedge pressure (PCWP) ≥25 mm Hg with a PCWP to right atrial pressure gradient ≥8 mm Hg will be randomized 1:1 to the APTURE shunt vs sham control. Key exclusion criteria include severe HF, significant valvular disease, and more than mild right ventricular dysfunction. The primary endpoints are the safety of the APTURE device at 30 days and change in workload-corrected PCWP normalized to bodyweight at 6 months. Secondary endpoints include changes in patient-reported outcomes, and hemodynamic and echocardiographic parameters through 5 years. The trial will also explore the impact of the device on short-term cardiac remodelling and intra-cardiac flow patterns using multi-modality imaging. Conclusions The ALT-FLOW II trial will evaluate the safety and performance of the APTURE system in symptomatic HFpEF and HFmrEF patients with elevated left atrial pressure.
Contemporary Outcomes of TAVR Using a Balloon-Expandable Valve in Patients With Severe Mitral Stenosis: Insights From the Transcatheter Valve Therapies Registry
BACKGROUND: While initial data for transcatheter aortic valve replacement (TAVR) in aortic stenosis patients with mitral stenosis (MS) suggested a poor short-term prognosis, outcomes for contemporary balloon-expandable valves remain unknown. The aim of this retrospective multicenter registry study was to compare the potential impact of MS on TAVR outcomes with balloon-expandable valves. METHODS: Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapies Registry and Centers for Medicare & Medicaid Services claims data were used to obtain a cohort of 327 925 patients who underwent TAVR with current balloon-expandable valves (SAPIEN 3, SAPIEN 3 Ultra, or SAPIEN 3 Ultra Resilia) between June 2015 and December 2022 across 791 sites. Severe MS (defined as >10 mm Hg mean gradient or <1.5 cm 2 area) was compared with mild or less MS (defined as <5 mm Hg mean gradient and >2 cm 2 area) using propensity matching to minimize confounding variables. RESULTS: Patients with severe MS (n=8500; 2.6%) had a higher number of comorbid conditions, Society of Thoracic Surgeons risk scores, and were more often women than patients with mild or less MS at the time of index TAVR. While patients with severe MS had worse outcomes at 30 days, when propensity-matched, patients exhibited similar 30-day rates of death (3.2% versus 3.0%), stroke (2.4% versus 2.2%), major vascular complications (1.6% versus 1.6%), device implant success (98.9% versus 99.2%), and new dialysis (0.7% versus 0.5%), with higher rates of pacemaker implantation (11.3% versus 9.4%; P <0.001). By 1 year, there was no difference in the change in the KCCQ (Kansas City Cardiomyopathy Questionnaire) overall score from baseline to 1 year (30.7±27.0 versus 31.9±27.0; P =0.07). By 3 years, an increase in the mortality rate (45.1% versus 40.9%; P <0.001) of patients with severe MS was observed. CONCLUSIONS: MS in isolation is not associated with worsened short-term outcomes among patients undergoing contemporary TAVR with balloon-expandable valves.
Left Atrial to Coronary Sinus Shunting for Treatment of Heart Failure with Mildly Reduced or Preserved Ejection Fraction: The ALT FLOW Early Feasibility Study 1-Year Results
Abstract Aims Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. Methods and results Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was −5.7 (−8.6, −2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I–II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20–30) and 27 (22–32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. Conclusions In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.