Abstract Aims Heart failure (HF) with preserved (HFpEF) and mildly reduced (HFmrEF) ejection fraction are prevalent, yet frequently underdiagnosed syndromes associated with high morbidity and mortality, impaired quality of life, and escalating healthcare expenditures. Although guideline-directed medications like SGLT2 inhibitors have been shown to reduce the risk of hospitalization and cardiovascular death, their use remains limited and substantial residual risk persists. This trial aims to evaluate the safety and performance of a novel left-atrium-to-coronary-sinus shunt (Edwards APTURE transcatheter shunt system) in HFpEF and HFmrEF patients. Methods ALT-FLOW II is a prospective multi-centre, randomized, sham-controlled, double-blinded (patient and assessor) trial. Approximately 100 symptomatic HF patients aged ≥18 years with left ventricular ejection fraction >40% and exercise pulmonary capillary wedge pressure (PCWP) ≥25 mm Hg with a PCWP to right atrial pressure gradient ≥8 mm Hg will be randomized 1:1 to the APTURE shunt vs sham control. Key exclusion criteria include severe HF, significant valvular disease, and more than mild right ventricular dysfunction. The primary endpoints are the safety of the APTURE device at 30 days and change in workload-corrected PCWP normalized to bodyweight at 6 months. Secondary endpoints include changes in patient-reported outcomes, and hemodynamic and echocardiographic parameters through 5 years. The trial will also explore the impact of the device on short-term cardiac remodelling and intra-cardiac flow patterns using multi-modality imaging. Conclusions The ALT-FLOW II trial will evaluate the safety and performance of the APTURE system in symptomatic HFpEF and HFmrEF patients with elevated left atrial pressure.
Impacts of Hospital Volume and Patient-Hospital Distances on Outcomes of Older Adults Receiving Percutaneous Microaxial Ventricular Assist Devices for Cardiogenic Shock
BACKGROUND: Percutaneous microaxial ventricular assist devices (pVADs) have the potential to reduce mortality of patients with cardiogenic shock (CS). However, the association between the distribution of pVAD-performing centers and outcomes of CS has not been explored. METHODS: This observational study included Medicare fee-for-service beneficiaries aged 65 to 99 years treated with pVAD for CS from 2016 to 2020. It examined the associations between patient outcomes and 2 exposure variables: hospitals’ procedure volumes of pVAD and patient-hospital distances (in quintiles [Qn]). We developed Cox proportional hazards regression for 180-day mortality and heart failure readmission rates, and multivariable logistic regression for in-hospital outcomes, adjusting for patient demographics, comorbidities, concomitant treatments, and hospital characteristics, including CS volume, teaching status, and the ability to perform extracorporeal membrane oxygenation. RESULTS: A total of 6637 patients with CS underwent pVAD at 1041 hospitals, with the annualized hospital volume ranging widely from 0.3 to 55.6 cases/year. Patients treated at higher-volume centers experienced lower 180-day mortality compared with those treated at lower-volume centers (Qn1=reference; Qn2: adjusted hazard ratio [aHR], 0.88 [95% CI, 0.79–0.97]; Qn3: aHR, 0.88 [95% CI, 0.79–0.98]; Qn4: aHR, 0.88 [95% CI, 0.78–0.99]; Qn5: aHR, 0.84 [95% CI, 0.74–0.95]; P for trend, 0.026), while we found no evidence that patient-hospital distances were associated with mortality (Qn1=reference; Qn2: aHR, 0.99 [95% CI, 0.89–1.09]; Qn3: aHR, 0.94 [95% CI, 0.85–1.04]; Qn4: aHR, 1.01 [95% CI, 0.92–1.11]; Qn5: aHR, 0.91 [95% CI, 0.82–1.01]; P for trend, 0.160). We found no evidence that the hospital volume and patient-hospital distances were associated with in-hospital bleeding, intracranial hemorrhage, or renal replacement therapy initiation. CONCLUSIONS: Hospital volume was more strongly associated with mortality than patient-hospital distances, suggesting that rational distribution of pVAD-performing centers while ensuring adequate procedure volumes may optimize patient mortality.
Left Atrial to Coronary Sinus Shunting for Treatment of Heart Failure with Mildly Reduced or Preserved Ejection Fraction: The ALT FLOW Early Feasibility Study 1-Year Results
Abstract Aims Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. Methods and results Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was −5.7 (−8.6, −2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I–II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20–30) and 27 (22–32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. Conclusions In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.
The Jarvik 2000 Left Ventricular Assist Device: Results of the United States Bridge to Transplant Trial
The Jarvik 2000 bridge to transplant investigational device exemption study was a multicentered, prospective study of 150 UNOS status I patients implanted with the Jarvik 2000 between 2005 and 2012. During the study period, there were numerous modifications of the system that included converting from pin to cone bearings. Results were analyzed for three cohorts: total (n = 150), pin (n = 128), and cone (n = 22). Baseline demographics included age (52 ± 13), gender (79% male), size (BSA 1.98), and etiology (37% idiopathic dilated cardiomyopathy; 43% Ischemic). Seventy percent of patients were either INTERMACS 1 or 2. The primary endpoint—defined as successful transplantation or listing at 180 days (prespecified at 65%; 95% lower CI: 57%)—was successfully achieved for the total cohort (67.3%; 95% CI: 59.5%–74.3%; p = 0.006). In subgroup analysis of the more contemporary, cone-bearing group, the primary endpoint was met in 91% (95% CI: 72%–97.5%; p = 0.001). Compared with pin patients, cone-bearing patients had less hemolysis as well as decreased end-organ dysfunction. Functional and quality of life scores improved after implantation independent type of bearing. In conclusion, despite a particularly sick patient population, the Jarvik 2000 was shown to be effective in supporting the advanced HF patient.