Abstract Introduction Left atrial-to-coronary sinus (LA-to-CS) shunting through the APTURE transcatheter shunt system aims to unload the LA while preserving the interatrial septum. This article aims to examine the 3-year health status, functional capacity, and clinical outcomes of the ALT-FLOW Early Feasibility Study (EFS). Methods Device safety, patency, and echocardiographic parameters, but also symptoms, health status, and exercise capacity were assessed in patients with left ventricular ejection fraction (LVEF) > 40% (n & 95). Meta-Analysis Global Group in Chronic Heart Failure (MAGGIC) score predicted 3-year all-cause mortality was compared with observed mortality assessed by Kaplan–Meier analysis using adjudicated events. Predicted and observed HF hospitalization (HFH)-free survival rates were also compared. Results At 3 years, the safety profile remained stable with no new safety signals, and all implanted shunts remained patent. 76.3% of patients improved by at least one NYHA class, and mean KCCQ Overall Summary Scores increased by 25 points from baseline (P < .0001). The 6-min walk distance improved by an average of 39 m (P & .002). These benefits were consistent regardless of baseline pulmonary vascular resistance (PVR). Right heart echocardiographic parameters after 3 years were stable, though a reduction in TAPSE was observed, primarily in the high PVR subgroup. The observed 3-year survival was significantly higher than the MAGGIC-predicted survival (84.4% vs 70.2, respectively; P & .009), as well as the HFH-free survival (68.0% vs 24.0%, respectively; P < 0001). Conclusion In patients with HF and LVEF >40%, the APTURE LA-to-CS shunting confirmed an acceptable safety profile with stable right heart parameters and sustained improvements in symptoms, quality of life, and functional capacity at 3 years. Observed survival and HFH were superior to MAGGIC predictions.
Left Atrial to Coronary Sinus Shunting for Treatment of Heart Failure with Mildly Reduced or Preserved Ejection Fraction: The ALT FLOW Early Feasibility Study 1-Year Results
Abstract Aims Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. Methods and results Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was −5.7 (−8.6, −2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I–II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20–30) and 27 (22–32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. Conclusions In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.