Back to Authors

Griffith, Bartley P.

https://orcid.org/0000-0003-3015-9322

Mayo Clinic

University of Maryland, Baltimore

Citations 3

The Jarvik 2000 Left Ventricular Assist Device: Results of the United States Bridge to Transplant Trial
Selzman, Craig H. , Feller, Erika , Walker, Jordan C., Sheridan, Brett C. , Daly, Richard C. , Anyanwu, Ani C., Madigan, Dave, Liu, Ping‐Yu , Frazier, O.H., Jorde, Ulrich P. , Griffith, Bartley P. , Silvestry, Scott

ASAIO Journal | April 14, 2022 | Volume: 69 | Issue: 2 | Pages: 174-182

10.1097/mat.0000000000001750 Get It

The Jarvik 2000 bridge to transplant investigational device exemption study was a multicentered, prospective study of 150 UNOS status I patients implanted with the Jarvik 2000 between 2005 and 2012. During the study period, there were numerous modifications of the system that included converting from pin to cone bearings. Results were analyzed for three cohorts: total (n = 150), pin (n = 128), and cone (n = 22). Baseline demographics included age (52 ± 13), gender (79% male), size (BSA 1.98), and etiology (37% idiopathic dilated cardiomyopathy; 43% Ischemic). Seventy percent of patients were either INTERMACS 1 or 2. The primary endpoint—defined as successful transplantation or listing at 180 days (prespecified at 65%; 95% lower CI: 57%)—was successfully achieved for the total cohort (67.3%; 95% CI: 59.5%–74.3%; p = 0.006). In subgroup analysis of the more contemporary, cone-bearing group, the primary endpoint was met in 91% (95% CI: 72%–97.5%; p = 0.001). Compared with pin patients, cone-bearing patients had less hemolysis as well as decreased end-organ dysfunction. Functional and quality of life scores improved after implantation independent type of bearing. In conclusion, despite a particularly sick patient population, the Jarvik 2000 was shown to be effective in supporting the advanced HF patient.
Strategic application of modular risk components to safely increase lung transplantation volume
Pasrija, Chetan , Parchment, Nathaniel , Tran, Douglas , Mackowick, Kristen M., Boulos, Francesca, Iacono, Aldo , Kim, June Myung , Griffith, Bartley P. , Sánchez, Pablo G. , Kon, Zachary N. , Pham, Si M. , Pasrija, Chetan

Journal of Cardiac Surgery | July 28, 2020 | Volume: 35 | Issue: 9 | Pages: 2177-2184

10.1111/jocs.14874 Get It

Individualized Antithrombotic Therapy in Heartware HVAD Recipients
Sorensen, Erik N. , Voorhees, Hannah J. , Dees, Lynn, Kon, Zachary N. , Griffith, Bartley P. , Feller, Erika , Pham, Si M.

ASAIO Journal | February 16, 2018 | Volume: 65 | Issue: 1 | Pages: 29-35

10.1097/mat.0000000000000751 Get It

There are no evidence-based guidelines for antithrombotic therapy in left ventricular assist device patients. We evaluated the efficacy of a multi-agent, test-guided protocol, which remained consistent throughout our use of the Heartware HVAD. Thrombelastography and platelet function analyzer (PFA)-100 guide antiplatelet titration. Goals are normal kaolin thrombelastography maximum amplitude and prolonged PFA-100. We analyzed incidence and rates of nonprocedural bleeding, stroke, and pump thrombosis for all 81 primary Heartware left ventricular assist devices implanted since 2011. For each event, we examined whether each test was within goal range. We also compared medication burden and dosage between patients with and without events. Pump thrombosis and hemorrhagic stroke each occurred in two patients (2.5%; 0.03 events/patient-year [EPPY]), and ischemic stroke in six (7.4%; 0.10 EPPY). Nonprocedural bleeding occurred 75 times in 34 patients (42%; 1.24 EPPY), primarily gastrointestinal (28%; 0.66 EPPY). Subtherapeutic international normalized ratio (INR) was the most common at thrombotic events; supratherapeutic partial thromboplastin time, international normalized ratio (INR), and PFA-adenosine diphosphate (ADP) were common at bleeding events. Medication burden and dosage were lower in patients with events than in stable patients. Protocol-guided antithrombotic therapy resulted in low rates of pump thrombosis and hemorrhagic stroke. Ischemic stroke and gastrointestinal bleeding rates were higher than in a comparable HVAD population. Optimization of our protocol to decrease its complexity and to reduce bleeding is underway.