Abstract 12017: New-Onset Diabetes After Heart Transplantation is associated With Worse Long-term Survival: A Propensity Matched Analysis of a National Registry.
Introduction: Limited data is available regarding the incidence of new-onset diabetes mellitus (NODM) after heart transplantation and it`s impact on patient survival. Hypothesis: Methods: From the United Network of Organ Sharing database (January 2004 to September 2014), we identified 13,353 patients without pre-operative diabetes mellitus undergoing heart transplantation. Multivariable Cox regression was implemented to determine predictors for the development of NODM. A matched cohort of New-onset Diabetes mellitus (NODM (+)) and NODM (-) was generated by 1:1 nearest neighbor propensity-matching. The association of NODM with long-term survival was then estimated with robust Cox regression. Results are presented at the 95% Confidence level; all tests are two-tailed. Results: During the study period, 1,921 of 13,353 (14%) developed NODM. Estimated freedom from NODM was 97% (96-98%) & 77% (76 - 78%) at the end of 1 and 5 years respectively. Predictors for the development of NODM were recipient age > 50 years (HR 1.2 95% CI1.05, 1.3; p < 0.01), recipient BMI > 30 (HR 1.4 95% CI1.2, 1.6; p < 0.01) and race (African American vs Caucasian (HR 1.3 95% CI1.2, 1.5; p < 0.01)). Cox-regression of a propensity-matched cohort of 1921 NODM+ve and NODM-ve recipient-pairs demonstrates that NODM is associated with poorer survival (HR for mortality: 1.3 95% CI 1.1, 1.5; p < 0.001). Conclusions: More than one in ten heart transplant recipients develop NODM post heart transplantation. Obesity, older age, and African American race patients to be at higher risk for NODM. New onset diabetes was independently associated with an almost 30% reduced long-term survival. More than one in ten heart transplant recipients develop NODM post heart transplantation. Obesity, older age, and African American race patients to be at higher risk for NODM. New onset diabetes was independently associated with an almost 30% reduced long-term survival.
Self-expanding Transcatheter vs Surgical Aortic Valve Replacement in Intermediate-Risk Patients
Importance In patients with severe aortic valve stenosis at intermediate surgical risk, transcatheter aortic valve replacement (TAVR) with a self-expanding supra-annular valve was noninferior to surgery for all-cause mortality or disabling stroke at 2 years. Comparisons of longer-term clinical and hemodynamic outcomes in these patients are limited. Objective To report prespecified secondary 5-year outcomes from the Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement (SURTAVI) randomized clinical trial. Design, Setting, and Participants SURTAVI is a prospective randomized, unblinded clinical trial. Randomization was stratified by investigational site and need for revascularization determined by the local heart teams. Patients with severe aortic valve stenosis deemed to be at intermediate risk of 30-day surgical mortality were enrolled at 87 centers from June 19, 2012, to June 30, 2016, in Europe and North America. Analysis took place between August and October 2021. Intervention Patients were randomized to TAVR with a self-expanding, supra-annular transcatheter or a surgical bioprosthesis. Main Outcomes and Measures The prespecified secondary end points of death or disabling stroke and other adverse events and hemodynamic findings at 5 years. An independent clinical event committee adjudicated all serious adverse events and an independent echocardiographic core laboratory evaluated all echocardiograms at 5 years. Results A total of 1660 individuals underwent an attempted TAVR (n = 864) or surgical (n = 796) procedure. The mean (SD) age was 79.8 (6.2) years, 724 (43.6%) were female, and the mean (SD) Society of Thoracic Surgery Predicted Risk of Mortality score was 4.5% (1.6%). At 5 years, the rates of death or disabling stroke were similar (TAVR, 31.3% vs surgery, 30.8%; hazard ratio, 1.02 [95% CI, 0.85-1.22]; P = .85). Transprosthetic gradients remained lower (mean [SD], 8.6 [5.5] mm Hg vs 11.2 [6.0] mm Hg; P &lt; .001) and aortic valve areas were higher (mean [SD], 2.2 [0.7] cm 2 vs 1.8 [0.6] cm 2 ; P &lt; .001) with TAVR vs surgery. More patients had moderate/severe paravalvular leak with TAVR than surgery (11 [3.0%] vs 2 [0.7%]; risk difference, 2.37% [95% CI, 0.17%- 4.85%]; P = .05). New pacemaker implantation rates were higher for TAVR than surgery at 5 years (289 [39.1%] vs 94 [15.1%]; hazard ratio, 3.30 [95% CI, 2.61-4.17]; log-rank P &lt; .001), as were valve reintervention rates (27 [3.5%] vs 11 [1.9%]; hazard ratio, 2.21 [95% CI, 1.10-4.45]; log-rank P = .02), although between 2 and 5 years only 6 patients who underwent TAVR and 7 who underwent surgery required a reintervention. Conclusions and Relevance Among intermediate-risk patients with symptomatic severe aortic stenosis, major clinical outcomes at 5 years were similar for TAVR and surgery. TAVR was associated with superior hemodynamic valve performance but also with more paravalvular leak and valve reinterventions.
Revascularization in ischaemic heart failure with preserved ejection fraction: a nationwide cohort study
Aims Despite the common occurrence of coronary artery disease (CAD) and heart failure (HF) with preserved ejection fraction (HFpEF), there is limited evidence to guide revascularization. Methods and Results We investigated the long‐term outcomes of coronary artery bypass grafting (CABG) in patients with HF and significant CAD across the spectrum of ejection fraction, using a large national cohort of patients from the Veteran Affairs (VA) Medical Centers in the US. Patients with HF were stratified into groups, HFpEF, HF with mid‐range ejection fraction (HFmrEF), and HF with reduced ejection fraction (HFrEF) and compared to patients with no preoperative HF. We analysed 10 396 patients. Despite an increased hazard in the first year following revascularization, the long‐term survival (median follow‐up 6.6 years; interquartile range 3.7–10.1) of HFpEF post‐CABG was similar to controls (hazard ratio 0.85, 95% confidence interval 0.68‐1.06), but survival progressively declined with HFmrEF and HFrEF. Similar trends were seen with recurrent HF hospitalization with lower risk with baseline HFpEF (43.9 ± 6.9/100 patient‐years) compared to HFmrEF (65.9 ± 3.8/100 patient‐years) and HFrEF (93.4 ± 4.8/100 patient‐years). Although HFpEF patients had lower mortality and HF hospitalization post‐CABG compared to patients with a lower ejection fraction, they experienced the highest rates of future myocardial infarction. Conclusion Although HFpEF patients with CAD have greater short‐term risk post‐CABG, their long‐term survival is comparable to controls. However, they are at increased risk for HF hospitalizations and myocardial infarction. These data support the safety of CABG in HFpEF patients and suggest continuum of mortality risk for ischaemic HF when stratified by baseline ejection fraction before revascularization.
Pump Position Impacts HeartMate II Left Ventricular Assist Device Thrombosis
The PREVENtion of HeartMate II pump Thrombosis through clinical management (PREVENT) study was a multicenter, prospective investigation to evaluate the rate of pump thrombosis (PT) with adoption of a uniform set of surgical and medical practices for left ventricular assist device implantation. We sought to quantify pump position at baseline and retrospectively define a pump position associated with poor clinical outcomes. Chest x-rays at baseline were prospectively obtained per protocol. Pump pocket depth, inflow cannula (IC) angle relative to the pump, and IC angle relative to the vertical were measured. Pumps falling in the tail-ends of the IC angle and pump pocket depth distributions were categorized as having an extreme pump position within the PREVENT study. Patients with extreme pump position had a significantly higher risk of confirmed and suspected PT, hemolysis, and elevated lactate dehydrogenase. In a multivariable analysis of survival free of confirmed PT, extreme pump position was an independent risk factor (hazard ratio = 3.6; 95% confidence interval = 1.5–8.9; p = 0.006) when adjusting for differences in pump speed and anticoagulation level. Our analysis shows that HeartMate II pump position at implant can significantly impact event-free survival and the incidence of adverse events at 6 months.