Back to Authors

Abizaid, Alexandre

0000-0001-8689-9990

Mayo Clinic

Instituto do Coração da Universidade de São Paulo, São Paulo, Brazil (F.S.d.B., A.A.).

Citations 3

One-Year Outcomes of Transseptal Mitral Valve-in-Valve in Intermediate Surgical Risk Patients
Malaisrie, S. Chris , Guerrero, Mayra , Davidson, Charles J. , Shah, Pinak , Kaneko, Tsuyoshi , Poon, Karl, Levisay, Justin , Xiao, Yu , Pîbarot, Philippe , Leon, Martin B. , Mack, Michael J. , Zajarías, Alan , Investigators, on behalf of the PARTNER 3 Mitral Valve-in-Valve Study, Davidson, Charles J. , Abizaid, Alexandre , Shah, Pinak , Kaneko, Tsuyoshi , Levisay, Justin , Yu, Xiao , Pibarot, Phillippe , Hahn, Rebecca T , Mack, Michael J , Guerrero, Mayra E , Williams, Mathew , Brito, Fábio Sândoli de , Abizaid, Alexandre , Blanke, Philipp , Investigators, on behalf of the PARTNER 3 Mitral Valve-in-Valve Study

Circulation: Cardiovascular Interventions | July 22, 2024 | Volume: 17 | Issue: 8 | Pages: No page available

10.1161/circinterventions.123.013782 Get It

BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03193801.
Standardized Definition of Structural Valve Degeneration for Surgical and Transcatheter Bioprosthetic Aortic Valves
Dvir, Danny , Bourguignon, Thierry , Rosenhek, Raphaël , Webb, John G. , Treede, Hendrik , Enriquez‐Sarano, Maurice , Feldman, Ted , Wijeysundera, Harindra C. , Topilsky, Yan , Aupart, Michel, Reardon, Michael J. , Szeto, Wilson Y. , Gammie, James S. , Yoganathan, Ajit P. , Arbel, Yaron , Borger, Michael A. , Simonato, Matheus , Reisman, Mark, Makkar, Raj , Abizaid, Alexandre , Dahle, Gry , Aldea, Gabriel S. , Leipsic, Jonathon , Pîbarot, Philippe , Moat, Neil, Mack, Michael J. , Leon, Martin B. , Topilsky, Yan , Sarano, Maurice E, Pibarot, Phillippe , Enriquez-Sarano, Maurice , Otto, Catherine M , Hahn, Rebecca T , Mackensen, G. Burkhard , Kornowski, Ran , McCabe, James M , Kappetein, A. Pieter , Topilsky, Yan , Reardon, Michael J , Abizaid, Alexandre

Circulation | January 22, 2018 | Volume: 137 | Issue: 4 | Pages: 388-399

10.1161/circulationaha.117.030729 Get It

Bioprostheses are prone to structural valve degeneration, resulting in limited long-term durability. A significant challenge when comparing the durability of different types of bioprostheses is the lack of a standardized terminology for the definition of a degenerated valve. This issue becomes especially important when we try to compare the degeneration rate of surgically inserted and transcatheter bioprosthetic valves. This document, by the VIVID (Valve-in-Valve International Data), proposes practical and standardized definitions of valve degeneration and provides recommendations for the timing of clinical and imaging follow-up assessments accordingly. Its goal is to improve the quality of research and clinical care for patients with deteriorated bioprostheses by providing objective and strict criteria that can be utilized in future clinical trials. We hope that the adoption of these criteria by both the cardiological and surgical communities will lead to improved comparability and interpretation of durability analyses.
One‐year clinical outcomes after sirolimus‐eluting coronary stent implantation in diabetics enrolled in the worldwide e‐SELECT registry
Bartorelli, Antonio L. , Assenza, Gabriele Egidy , Abizaid, Alexandre , Banning, Adrian , Džavík, Vladimír , Ellis, Stephen G. , Gao, Runlin, Holmes, David R. , Jeong, Myung Ho , Legrand, Victor , Spaulding, Christian , Worthley, Stephen G., Urban, Philip , Investigators, for the e‐SELECT, Gao, Runlin, Jeong, Myung Ho , Neumann, Franz–Josef , Investigators, for the e‐SELECT, Banning, Adrian , Abizaid, Alexandre

Catheterization and Cardiovascular Interventions | May 27, 2015 | Volume: 87 | Issue: 1 | Pages: 52-62

10.1002/ccd.26026 Get It

BackgroundDiabetes mellitus has worse outcome after percutaneous coronary intervention.AimWe assessed stent thrombosis (ST), major adverse cardiac events (MACE), and major bleeding rates at 1 year after implantation of sirolimus‐eluting stents (SES) in patients with diabetes mellitus in a large multicenter registry.MethodsFrom May 2006 to April 2008, 15,147 unselected consecutive patients were enrolled at 320 centers in 56 countries in a prospective, observational registry after implantation of ≥ 1 SES. Source data were verified in 20% randomly chosen patients at > 100 sites. Adverse events were adjudicated by an independent Clinical Event Committee.ResultsComplete follow‐up at 1 year was obtained in 13,693 (92%) patients, 4,577 (30%) of whom were diabetics. Within diabetics, 1,238 (9%) were insulin‐treated diabetics (ITD). Diabetics were older (64 vs. 62 years, P < 0.001), with higher incidence of major coronary risk factors, co‐morbidities, and triple‐vessel coronary artery disease. Coronary lesions had smaller reference vessel diameter (2.88 ± 0.46 vs. 2.93 ± 0.45 mm, P < 0.001) and were more often heavily calcified (26.1% vs. 22.6%, P < 0.001). At 1 year, diabetics had higher MACE rate (6.8% vs. 3.9%, P < 0.001) driven by ITD (10.6% vs. 5.5%, P < 0.001). Finally, diabetics had significant increase in ST (1.7% vs. 0.7%, P < 0.001), principally owing to ITD (3.4% vs. 1.1%, P < 0.001). There was an overall low risk of major bleeding during follow‐up, without significant difference among subgroups.ConclusionsIn the e‐SELECT registry, diabetics represented 30% of patients undergoing SES implantation and had significantly more co‐morbidities and complex coronary lesions. Although 1‐year follow‐up documented good overall outcome in diabetics, higher ST and MACE rates were observed, mainly driven by ITD. © 2015 Wiley Periodicals, Inc.