BACKGROUND: Transcatheter mitral valve-in-valve replacement offers a less-invasive alternative for high-risk patients with bioprosthetic valve failure. Limited experience exists in intermediate-risk patients. We aim to evaluate 1-year outcomes of the PARTNER 3 mitral valve-in-valve study. METHODS: This prospective, single-arm, multicenter study enrolled symptomatic patients with a failing mitral bioprosthesis demonstrating greater than or equal to moderate stenosis and regurgitation and Society of Thoracic Surgeons score ≥3% and <8%. A balloon-expandable transcatheter heart valve (SAPIEN 3, Edwards Lifesciences) was used via a transeptal approach. The primary end point was the composite of all-cause mortality and stroke at 1 year. RESULTS: A total of 50 patients from 12 sites underwent mitral valve-in-valve from 2018 to 2021. The mean age was 70.1±9.7 years, mean Society of Thoracic Surgeons score was 4.1%±1.6%, and 54% were female. There were no primary end point events (mortality or stroke) through 1 year, and no left-ventricular outflow tract obstruction, endocarditis, or mitral valve reintervention was reported. Six patients (12%) required rehospitalization, including heart failure (n=2), minor procedural side effects (n=2), and valve thrombosis (n=2; both resolved with anticoagulation). An additional valve thrombosis was associated with no significant clinical sequelae. From baseline to 1 year, all subjects with available data had none/trace or mild (grade 1+) mitral regurgitation and the New York Heart Association class improved in 87.2% (41/47) of patients. CONCLUSIONS: Mitral valve-in-valve with a balloon-expandable valve via transseptal approach in intermediate-risk patients was associated with improved symptoms and quality of life, adequate transcatheter valve performance, and no mortality or stroke at 1-year follow-up. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT03193801.
Cardiac surgery considerations and lessons learned during the COVID‐19 pandemic
BackgroundSystematic evaluation of complex flow in the true lumen and false lumen (TL, FL) is needed to better understand which patients with chronic descending aortic dissection (DAD) are predisposed to complications.PurposeTo develop quantitative hemodynamic maps from 4D flow MRI for evaluating TL and FL flow characteristics.Study TypeRetrospective.PopulationIn all, 20 DAD patients (age = 60 ± 11 years; 12 male) (six medically managed type B AD [TBAD], 14 repaired type A AD [rTAAD] now with ascending aortic graft [AAo] or elephant trunk [ET1] repair) and 21 age‐matched controls (age = 59 ± 10 years; 13 male) were included.Field Strength/Sequence1.5T, 3T, 4D flow MRI.Assessment4D flow MRI was acquired in all subjects. Data analysis included 3D segmentation of TL and FL and voxelwise calculation of forward flow, reverse flow, flow stasis, and kinetic energy as quantitative hemodynamics maps.Statistical TestsAnalysis of variance (ANOVA) or Kruskal–Wallis tests were performed for comparing subject groups. Correlation and Bland–Altman analysis was performed for the interobserver study.ResultsPatients with rTAAD presented with elevated TL reverse flow (AAo repair: P = 0.004, ET1: P = 0.018) and increased TL kinetic energy (AAo repair: P = 0.0002, ET1: P = 0.011) compared to controls. In addition, TL kinetic energy was increased vs. patients with TBAD (AAo repair: P = 0.021, ET1: P = 0.048). rTAAD was associated with higher FL kinetic energy and lower FL stasis compared to patients with TBAD (AAo repair: P = 0.002, ET1: P = 0.024 and AAo repair: P = 0.003, ET1: P = 0.048, respectively).Data ConclusionQuantitative maps from 4D flow MRI demonstrated global and regional hemodynamic differences between DAD patients and controls. Patients with rTAAD vs. TBAD had significantly altered regional TL and FL hemodynamics. These findings indicate the potential of 4D flow MRI‐derived hemodynamic maps to help better evaluate patients with DAD.Level of Evidence: 3Technical Efficacy Stage: 1J. Magn. Reson. Imaging 2020;51:1357–1368.
Association Between Left Atrial Appendage Occlusion and Readmission for Thromboembolism Among Patients With Atrial Fibrillation Undergoing Concomitant Cardiac Surgery
Background: In the initial PARTNER trial (Placement of Aortic Transcatheter Valves) of transcatheter aortic valve replacement for high-risk (HR) and inoperable patients, mortality at 1 year was 24% in HR and 31% in inoperable patients. A recent report of the 30-day outcomes with the low-profile SAPIEN 3 transcatheter aortic valve replacement system demonstrated very low rates of adverse events, but little is known about the longer-term outcomes with this device. Methods: Between October 2013 and September 2014, 583 HR (65%) or inoperable (35%) patients were treated via the transfemoral (84%) or transapical/transaortic (16%) access route at 29 US sites. Major clinical events at 1 year were adjudicated by an independent clinical events committee, and echocardiographic results were analyzed by a core laboratory. Results: Baseline characteristics included age of 83 years, 42% female, and median Society of Thoracic Surgeons score of 8.4%. At the 1-year follow-up, survival (all-cause) was 85.6% for all patients, 87.3% in the HR subgroup, and 82.3% in the inoperable subgroup. Survival free of all-cause and cardiovascular mortality in the transfemoral patients from the HR cohort was 87.7% and 93.3%, respectively. There was no severe paravalvular leak. Moderate paravalvular leak (2.7%) was associated with an increase in mortality at 1 year, whereas mild paravalvular leak had no significant association with mortality. Symptomatic improvement as assessed by the percentage of patients in New York Heart Association class III and IV (90.1% to 7.7% at 1 year; P <0.0001) and by Kansas City Cardiomyopathy Questionnaire overall summary score (improved from 46.9 to 72.4; P <0.0001) was marked. Multivariable predictors of 1-year mortality included alternative access, Society of Thoracic Surgeons score, and disabling stroke. Conclusions: In this large, adjudicated registry of SAPIEN 3 HR and inoperable patients, the very low rates of important complications resulted in a strikingly low mortality rate at 1 year. Between 30 and 365 days, the incidence of moderate paravalvular aortic regurgitation did not increase, and no association between mild paravalvular leak and 1-year mortality was observed, although a small increase in disabling stroke occurred. These results, which likely reflect device iteration and procedural evolution, support the use of transcatheter aortic valve replacement as the preferred therapy in HR and inoperable patients with aortic stenosis. Clinical Trial Registration : URL: http://www.clinicaltrials.gov . Unique identifier: NCT01314313.