Back to Authors

Allen, Bradley A

0000-0002-0667-137X

Mayo Clinic

Department of Radiology, Northwestern University, 737 N. Michigan Ave, Chicago, IL, USA.

Citations 4

Radiology: Cardiothoracic Imaging Highlights 2024
Catania, Roberta , Mukherjee, Aprateem , Chamberlin, Jordan , Calle, Francisco , Philomina, Preethi , Mastrodicasa, Domenico , Allen, Bradley D. , Hanneman, Kate , Chamberlin, Jordan H , Suchá, Dominika , Abbara, Suhny , Hanneman, Kate , Allen, Bradley A , Catania, Roberta , Suchá, Dominika

Radiology: Cardiothoracic Imaging | June 5, 2025 | Volume: 7 | Issue: 3 | Pages: No page available

10.1148/ryct.250064 Get It

The field of cardiothoracic imaging is expanding rapidly with new techniques that enable greater diagnostic accuracy and more personalized patient management, ultimately improving outcomes and enhancing clinical decision-making.
Cardiac MRI Myocardial Functional and Tissue Characterization Detects Early Cardiac Dysfunction in a Mouse Model of Chemotherapy‐Induced Cardiotoxicity
Naresh, Nivedita K. , Misener, Sol , Zhang, Zhouli, Yang, Cynthia , Ruh, Alexander , Bertolino, Nicola , Epstein, Frederick H. , Collins, Jeremy D. , Markl, Michael , Carr, James , Allen, Bradley D. , Allen, Bradley A , Collins, Jeremy , Markl, Michael , Zhang, Zhouli, Procissi, Daniele

NMR in Biomedicine | June 22, 2020 | Volume: 33 | Issue: 9 | Pages: No page available

10.1002/nbm.4327 Get It

BackgroundDoxorubicin and doxorubicin‐trastuzumab combination chemotherapy have been associated with cardiotoxicity that eventually leads to heart failure and may limit dose‐effective cancer treatment. Current diagnostic strategies rely on decreased ejection fraction (EF) to diagnose cardiotoxicity.PurposeThe aim of this study is to explore the potential of cardiac MR (CMR) imaging to identify imaging biomarkers in a mouse model of chemotherapy‐induced cardiotoxicity.MethodsA cumulative dose of 25 mg/kg doxorubicin was administered over three weeks using subcutaneous pellets (n = 9, Dox). Another group (n = 9) received same dose of Dox and a total of 10 mg/kg trastuzumab (DT). Mice were imaged at baseline, 5/6 weeks and 10 weeks post‐treatment on a 7T MRI system. The protocol included short‐axis cine MRI covering the left ventricle (LV) and mid‐ventricular short‐axis tissue phase mapping (TPM), pre‐ and post‐contrast T1 mapping, T2 mapping and Displacement Encoding with Stimulated Echoes (DENSE) strain encoded MRI. EF, peak myocardial velocities, native T1, T2, extracellular volume (ECV), and myocardial strain were quantified. N = 7 mice were sacrificed for histopathologic assessment of apoptosis at 5/6 weeks.ResultsGlobal peak systolic longitudinal velocity was reduced at 5/6 weeks in Dox (0.6 ± 0.3 vs 0.9 ± 0.3, p = 0.02). In the Dox group, native T1 was reduced at 5/6 weeks (1.3 ± 0.2 ms vs 1.6 ± 0.2 ms, p = 0.02), and relatively normalized at week 10 (1.4 ± 0.1 ms vs 1.6 ± 0.2 ms, p > 0.99). There was no change in EF and other MRI parameters and histopathologic results demonstrated minimal apoptosis in all mice (~1–2 apoptotic cell/high power field), suggesting early‐stage cardiotoxicity.ConclusionsIn a mouse model of chemotherapy‐induced cardiotoxicity using doxorubicin and trastuzumab, advanced CMR shows promise in identifying treatment‐related decrease in myocardial velocity and native T1 prior to the onset of cardiomyocyte apoptosis and reduction of EF.
Four-dimensional Flow Magnetic Resonance Imaging Quantification of Blood Flow in Bicuspid Aortic Valve
Gordon, Daniel , Abbasi, Muhannad , Lee, Jeesoo , Sarnari, Roberto, Sojoudi, Alireza , Wei, Qiao, Scott, Michael , Allen, Bradley D. , Blaisdell, Julie , Carr, James , Markl, Michael , Collins, Jeremy D. , Allen, Bradley A , Markl, Michael , Wei, Qiao

Journal of Thoracic Imaging | May 26, 2020 | Volume: 35 | Issue: 6 | Pages: 383-388

10.1097/rti.0000000000000535 Get It

Background: Four-dimensional (D) flow magnetic resonance imaging (MRI) is limited by time-consuming and nonstandardized data analysis. We aimed to test the efficiency and interobserver reproducibility of a dedicated 4D flow MRI analysis workflow. Materials and Methods: Thirty retrospectively identified patients with bicuspid aortic valve (BAV, age=47.8±11.8 y, 9 male) and 30 healthy controls (age=48.8±12.5 y, 21 male) underwent Aortic 4D flow MRI using 1.5 and 3 T MRI systems. Two independent readers performed 4D flow analysis on a dedicated workstation including preprocessing, aorta segmentation, and placement of four 2D planes throughout the aorta for quantification of net flow, peak velocity, and regurgitant fraction. 3D flow visualization using streamlines was used to grade aortic valve outflow jets and extent of helical flow. Results: 4D flow analysis workflow time for both observers: 5.0±1.4 minutes per case (range=3 to 10 min). Valve outflow jets and flow derangement was visible in all 30 BAV patients (both observers). Net flow, peak velocity, and regurgitant fraction was significantly elevated in BAV patients compared with controls except for regurgitant fraction in plane 4 (91.1±29.7 vs. 62.6±19.6 mL/s, 37.1% difference; 121.7±49.7 vs. 90.9±26.4 cm/s, 28.9% difference; 9.3±10.1% vs. 2.0±3.4%, 128.0% difference, respectively; P <0.001). Excellent intraclass correlation coefficient agreement for net flow: 0.979, peak velocity: 0.931, and regurgitant fraction: 0.928. Conclusion: Our study demonstrates the potential of an efficient data analysis workflow to perform standardized 4D flow MRI processing in under 10 minutes and with good-to-excellent reproducibility for flow and velocity quantification in the thoracic aorta.
Parametric Hemodynamic 4D Flow MRI Maps for the Characterization of Chronic Thoracic Descending Aortic Dissection
Jarvis, Kelly , Pruijssen, Judith T. , Son, Andre Y. , Allen, Bradley D. , Soulat, Gilles , Vali, Alireza , Hoel, Andrew W. , Eskandari, Mark K. , Carr, James , Markl, Michael , Collins, Jeremy D. , Allen, Bradley A , Markl, Michael , Barker, Alex J. , Malaisrie, S. Chris

Journal of Magnetic Resonance Imaging | November 12, 2019 | Volume: 51 | Issue: 5 | Pages: 1357-1368

10.1002/jmri.26986 Get It

BackgroundSystematic evaluation of complex flow in the true lumen and false lumen (TL, FL) is needed to better understand which patients with chronic descending aortic dissection (DAD) are predisposed to complications.PurposeTo develop quantitative hemodynamic maps from 4D flow MRI for evaluating TL and FL flow characteristics.Study TypeRetrospective.PopulationIn all, 20 DAD patients (age = 60 ± 11 years; 12 male) (six medically managed type B AD [TBAD], 14 repaired type A AD [rTAAD] now with ascending aortic graft [AAo] or elephant trunk [ET1] repair) and 21 age‐matched controls (age = 59 ± 10 years; 13 male) were included.Field Strength/Sequence1.5T, 3T, 4D flow MRI.Assessment4D flow MRI was acquired in all subjects. Data analysis included 3D segmentation of TL and FL and voxelwise calculation of forward flow, reverse flow, flow stasis, and kinetic energy as quantitative hemodynamics maps.Statistical TestsAnalysis of variance (ANOVA) or Kruskal–Wallis tests were performed for comparing subject groups. Correlation and Bland–Altman analysis was performed for the interobserver study.ResultsPatients with rTAAD presented with elevated TL reverse flow (AAo repair: P = 0.004, ET1: P = 0.018) and increased TL kinetic energy (AAo repair: P = 0.0002, ET1: P = 0.011) compared to controls. In addition, TL kinetic energy was increased vs. patients with TBAD (AAo repair: P = 0.021, ET1: P = 0.048). rTAAD was associated with higher FL kinetic energy and lower FL stasis compared to patients with TBAD (AAo repair: P = 0.002, ET1: P = 0.024 and AAo repair: P = 0.003, ET1: P = 0.048, respectively).Data ConclusionQuantitative maps from 4D flow MRI demonstrated global and regional hemodynamic differences between DAD patients and controls. Patients with rTAAD vs. TBAD had significantly altered regional TL and FL hemodynamics. These findings indicate the potential of 4D flow MRI‐derived hemodynamic maps to help better evaluate patients with DAD.Level of Evidence: 3Technical Efficacy Stage: 1J. Magn. Reson. Imaging 2020;51:1357–1368.