Back to Authors

McElhinney, Doff B

0000-0001-7242-0934

Mayo Clinic

Department of Cardiothoracic Surgery, Stanford University Medical Center, CA (D.B.M.E.).

Citations 9

Midterm Outcomes in a Pooled Cohort of Harmony Transcatheter Pulmonary Valve Recipients
Morray, Brian H. , Gillespie, Matthew J. , Cheatham, John P. , Salavitabar, Arash , Peng, Lynn F., Jones, Thomas K. , Levi, Daniel S. , Gray, Robert G. , Asnes, Jeremy D. , Cabalka, Allison K. , Fujimoto, Kazuto , Qureshi, Athar M. , Bergersen, Lisa, Haugan, Daniel, McElhinney, Doff B. , Asnes, Jeremy D , Benson, Lee N. , McElhinney, Doff B , Jones, Thomas K , Morray, Brian H , Cabalka, Allison , Bergersen, Lisa

Circulation: Cardiovascular Interventions | July 16, 2025 | Volume: 18 | Issue: 9 | Pages: No page available

10.1161/circinterventions.125.015196 Get It

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is designed to treat severe pulmonary regurgitation in the native or surgically repaired right ventricular (RV) outflow tract. Early outcomes after TPV replacement with the Harmony valve have been positive, but longer-term data are limited. METHODS: The study included patients who received a commercially available TPV22 or TPV25 device as part of the nonrandomized, prospective Native Outflow Tract Early Feasibility Study, Harmony Pivotal Trial, and Continued Access Study. Patients completed at least 3 years of follow-up, and outcomes to 5 years were reported when available. RESULTS: Eighty-nine patients were catheterized, and 86 were successfully implanted with a Harmony TPV. Median duration of follow-up was 5 (range 0–6) years in the TPV22 group and 3 (1–4) years in the TPV25 group. At 3 years, all patients with a TPV22 and 96% of those with a TPV25 had ≤mild pulmonary regurgitation. By magnetic resonance imaging, significant improvements from preimplant to 2 years were observed in RV end-diastolic volume index, RV to left ventricular end-diastolic volume ratio, and effective RV stroke volume (all P <0.001). SF-36 quality-of-life scores improved after Harmony implantation and were sustained over 3 years. Early cases of ventricular tachycardia resolved, and there were no new arrhythmias. Adverse events up to 5 years included 3 deaths unrelated to the device or procedure, 2 cases of endocarditis that were treated (1 medically, 1 transcatheter debulking of a vegetation) and resolved, 6 patients with RV outflow tract obstruction or thrombosis resulting in valve-in valve procedures, and 1 major stent fracture resulting in surgical explant. CONCLUSIONS: At 3 to 5 years, Harmony TPV replacement resulted in sustained valve competence, beneficial cardiac remodeling, and improved quality of life. Continued monitoring is needed to assess long-term outcomes and valve performance. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01762124; NCT02979587.
Transcatheter Pulmonary Valve Replacement With the Harmony Valve in Patients Who Do Not Meet Recommended Oversizing Criteria on the Screening Perimeter Plot
McElhinney, Doff B. , Gillespie, Matthew J. , Cabalka, Allison K. , Morray, Brian H. , Balzer, David T. , Qureshi, Athar M. , Hoskoppal, Arvind , Cabalka, Allison , Morray, Brian H , Qureshi, Athar M , Hoskoppal, Arvind K , Goldstein, Bryan H , McElhinney, Doff B , Aboulhosn, Jamil , Goldstein, Bryan H.

Circulation: Cardiovascular Interventions | April 12, 2024 | Volume: 17 | Issue: 5 | Pages: No page available

10.1161/circinterventions.123.013889 Get It

BACKGROUND: Anatomic selection for Harmony valve implant is determined with the aid of a screening report and perimeter plot (PP) that depicts the perimeter-derived radius along the right ventricular outflow tract (RVOT) and projects device oversizing. The PP provides an estimation of suitability for implant, but its sensitivity as a screening method is unknown. This study was performed to describe anatomic features and outcomes in patients who underwent Harmony TPV25 implant despite a PP that predicted inadequate oversizing. METHODS: We reviewed RVOT anatomic features and measurements in patients who underwent transcatheter pulmonary valve replacement with the Harmony TPV25 device despite a PP that predicted inadequate oversizing. RESULTS: This study included 22 patients. There were no unsuccessful implants or adverse valve-related events. Anatomic features varied, but all patients fit into 1 of 3 anatomic types characterized by differences in RVOT dimensions. Type 1 patients (n=9) had a long RVOT with a choke point and a wide main pulmonary artery. Type 2 patients (n=6) had a short RVOT that was pyramidal in shape, with no choke point, and extensive main pulmonary artery lengthening/expansion during systole. Type 3 patients (n=7) had a short, bulbous main pulmonary artery with a choke point and an open pulmonary artery bifurcation. CONCLUSIONS: Transcatheter pulmonary valve replacement with the Harmony valve is feasible in some patients whose PP fit analysis predicts inadequate oversizing. All cases in this series fit into 1 of 3 anatomic patterns, which are not identified in the screening report. Implanters must review cases individually to assess the feasibility of the implant.
Right ventricular outflow tract obstruction associated with neointimal tissue accumulation and distortion of the Harmony TPV25 stent frame: Potential mechanisms and treatment
Balzer, David T. , Asnes, Jeremy D. , Morray, Brian H. , Gillespie, Matthew J. , McElhinney, Doff B. , Cabalka, Allison K. , Asnes, Jeremy D , Morray, Brian H , McElhinney, Doff B , Steinberg, Zachary Louis

Catheterization and Cardiovascular Interventions | November 5, 2023 | Volume: 102 | Issue: 6 | Pages: 1078-1087

10.1002/ccd.30901 Get It

AbstractBackgroundThe Harmony TPV25 transcatheter pulmonary valve (Medtronic Inc.) is constructed with a self‐expanding stent frame comprising six zigged nitinol wires sewn together and covered with knitted polyester fabric, with flared inflow and outflow ends and a porcine pericardial valve sutured to the central portion of the device. It was approved for treatment of pulmonary regurgitation after prior right ventricular outflow tract repair in 2021. Early outcomes of this procedure have been excellent, but little is known about valve durability or ultimate mechanisms of dysfunction.MethodsWe collected data on patients who underwent reintervention for TPV25 dysfunction and described findings related to distortion of the stent frame and tissue accumulation.ResultsWe describe six patients who underwent valve‐in‐valve implant for TPV25 obstruction (peak catheterization gradient peak 28–73 mmHg) 10–28 months after implant. In all cases, there was tissue accumulation within the inflow and valve‐housing segments of the device and deformation of the self‐expanding valve frame characterized by variable circumferential narrowing at the junction between the valve housing and the inflow and outflow portions of the device, with additional geometric changes in all segments. All six patients underwent valve‐in‐valve implant that results in a final peak gradient ≤10 mmHg and no regurgitation.DiscussionThe occurrence of short‐term Harmony TPV25 dysfunction in multiple patients with a similar appearance of frame distortion and tissue accumulation within the inflow and valve housing portions of the device suggests that this may be an important failure mechanism for this valve. Potential causes of the observed findings are discussed. It is possible to treat this mechanism of TPV25 dysfunction with valve‐in‐valve implant using balloon expandable transcatheter valves.
Recommendations for Centers Performing Pediatric Heart Surgery in the United States
Backer, Carl L., Overman, David M. , Romano, Jennifer C., Tweddell, James S., Marino, Bradley S. , Bacha, Emile , Jaquiss, Robert, Zaidi, Ali N. , Gurvitz, Michelle , Costello, John M. , Pierick, Trudy A. , Ravekes, William, Reagor, James A. , Spaeth, James P., Mahle, William T. , Shin, Andrew Y. , Karamlou, Tara , Welke, Karl F. , Bryant, Roosevelt , Husain, S. Adil , Chen, Jonathan M., Wells, Winfield J., Glatz, Andrew C. , McElhinney, Doff B. , Parra, David , Pasquali, Sara K. , McElhinney, Doff B , Dearani, Joseph A. , Kumar, S. Ram , Jaquiss, Robert D.B. , Louis, James D. St. , Lopez, Keila N. , Kaza, Aditya K.

World Journal for Pediatric and Congenital Heart Surgery | September 22, 2023 | Volume: 14 | Issue: 5 | Pages: 642-679

10.1177/21501351231190353 Get It

Care and outcomes for the more than 40,000 patients undergoing pediatric and congenital heart surgery in the United States annually are known to vary widely. While consensus recommendations have been published across numerous fields as one mechanism to promote a high level of care delivery across centers, it has been more than two decades since the last pediatric heart surgery recommendations were published in the United States. More recent guidance is lacking, and collaborative efforts involving the many disciplines engaged in caring for these children have not been undertaken to date. The present initiative brings together professional societies spanning numerous care domains and congenital cardiac surgeons, pediatric cardiologists, nursing, and other healthcare professionals from diverse programs around the country to develop consensus recommendations for United States centers. The focus of this initial work is on pediatric heart surgery, and it is recommended that future efforts focus in detail on the adult congenital population. We describe the background, rationale, and methodology related to this collaborative effort, and recommendations put forth for Essential Care Centers (essential services necessary for any program), and Comprehensive Care Centers (services to optimize comprehensive and high-complexity care), encompassing structure, process, and outcome metrics across 14 domains.
Comparison of the investigational device exemption and post‐approval trials of the Melody transcatheter pulmonary valve
Kreutzer, Jacqueline , Armstrong, Aimee K. , Rome, Jonathan J. , Zellers, Thomas M. , Balzer, David T. , Zampi, Jeffrey D. , Javois, Alexander J., Turner, Daniel R. , Gray, Robert G. , Moore, John W. , Weng, Shicheng, Jones, Thomas K. , Khan, Danyal , Vincent, Julie A., Hellenbrand, William E. , Bergersen, Lisa , McElhinney, Doff B. , Cabalka, Allison K. , Gray, Robert G , Moore, John W , Jones, Thomas K , McElhinney, Doff B , Cheatham, John P.

Catheterization and Cardiovascular Interventions | March 29, 2021 | Volume: 98 | Issue: 2 | Pages: No page available

10.1002/ccd.29657 Get It

AbstractObjectiveWe compared 5‐year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post‐approval study (PAS) and the investigational device exemption (IDE) trial.BackgroundAs a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a “real‐world” environment. The 5‐year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared.MethodsThe cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time‐related outcomes and valve‐related adverse events were compared between the two trials with Kaplan–Meier curves and log‐rank testing.Results167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both.ConclusionsHemodynamic and time‐related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real‐world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post‐approval studies as part of the regulatory process for Class III medical devices.
Mortality prediction after transcatheter treatment of failed bioprosthetic aortic valves utilizing various international scoring systems: Insights from the Valve‐in‐Valve International Data (VIVID)
Aziz, Mina, Simonato, Matheus , Webb, John G. , Abdel‐Wahab, Mohamed , McElhinney, Doff B. , Duncan, Alison , Tchétché, Didier , Barbanti, Marco , Petronio, Anna Sonia , Maisano, Francesco , Ribeiro, Vasco Gama , Gaia, Diego Felipe , Rana, Ruhina , Kočka, Viktor , Mathur, Moses , Wijeysundera, Harindra C. , Hellig, Farrel, Bekeredjian, Raffi , Rihal, Charanjit S. , Dvir, Danny , Rihal, Charanjit, Maisano, Francesco , McElhinney, Doff B , Aziz, Mina, Nissen, Henrik , Rihal, Charanjit S. , Duffy, Stephen James

Catheterization and Cardiovascular Interventions | August 7, 2018 | Volume: 92 | Issue: 6 | Pages: 1163-1170

10.1002/ccd.27714 Get It

Abstract Background Transcatheter Aortic Valve Implantation (TAVI) is commonly used to deploy new bioprosthetic valves inside degenerated surgically implanted aortic valves in high risk patients. The three scoring systems used to assess risk of postprocedural mortality are: Logistic EuroSCORE (LES), EuroSCORE II (ES II), and Society of Thoracic Surgeons (STS). Objective The purpose of this study is to analyze the accuracy of LES, ES II, and STS in estimating all‐cause mortality after transcatheter aortic valve‐in‐valve (ViV) implantations, which was not assessed before. Methods Using the Valve‐in‐Valve International Data (VIVID) registry, a total of 1,550 patients from 110 centers were included. The study compared the observed 30‐day overall mortality vs. the respective predicted mortalities calculated by risk scores. The accuracy of prediction models was assessed based on calibration and discrimination. Results Observed mortality at 30 days was 5.3%, while average expected mortalities by LES, ES II and STS were 29.49 (± 17.2), 14.59 (± 8.6), and 9.61 (± 8.51), respectively. All three risk scores overestimated 30‐day mortality with ratios of 0.176 (95% CI 0.138–0.214), 0.342 (95% CI 0.264–0.419), and 0.536 (95% CI 0.421–0.651), respectively. 30‐day mortality ROC curves demonstrated that ES II had the largest AUC at 0.722, followed by STS at 0.704, and LES at 0.698. Conclusions All three scores overestimated mortality at 30 days with ES II showing the highest predictability compared to LES and STS; and therefore, should be recommended for ViV procedures. There is a need for a dedicated scoring system for patients undergoing ViV interventions.
Transcatheter interventions in adults with congenital heart disease: Surveys from the Society for Cardiovascular Angiography and Interventions to identify current patterns of care and perception on training requirements
Wadia, Subeer , Accavitti, Michael J., Kenny, Damien , Hijazi, Ziyad M. , Jones, Thomas K. , McElhinney, Doff B. , Kavinsky, Clifford J. , Wadia, Subeer K , Cabalka, Allison K. , Morgan, Gareth John , McElhinney, Doff B

Catheterization and Cardiovascular Interventions | May 11, 2017 | Volume: 90 | Issue: 3 | Pages: 418-424

10.1002/ccd.27151 Get It

Abstract Background Interventional catheterization is central to the care of Adults with Congenital Heart Disease (ACHD). Current standards for care provision and training in ACHD intervention are lacking. We sought to examine trends in current practice and training among interventionalists. Methods We analyzed the results of two separate international surveys in June 2016. One was sent to all active members from the Society of Cardiovascular Angiography and Interventions (SCAI) who self‐identified Structural Heart Disease or Congenital Heart Disease as a practice area. The second survey was conducted through the Pediatric Interventional Early Career Society (PICES) aimed at pediatric and adult congenital interventionalists in their first seven years after training. The total survey sample sizes were 1,535 and 112, respectively. Results Response rates for the SCAI and PICES surveys were 15% (237/1,535) and 75% (84/112), respectively. Most respondents (74%) worked at institutions with pediatric and adult facilities in proximity (major medical centers). While 75% of SCAI respondents believed complex transcatheter procedures should be performed by ACHD‐trained interventionalists or multidisciplinary teams, only 32% reported such care is being provided at the present time. Most pediatric and adult cardiologists surveyed (73%) do not believe current interventional fellowships provide adequate training for proficiency in ACHD interventions. Conclusions ACHD management remains underdeveloped in relative terms, particularly in the United States. Significant gaps in interventional standards of practice and future training needs were recognized by this study. Our survey should serve as an impetus to establish training guidelines for physicians who seek to perform ACHD interventions.
Transcatheter valve implantation for right atrium‐to‐right ventricle conduit obstruction or regurgitation after modified Björk–fontan procedure
Horlick, Eric , Eicken, Andreas , Asnes, Jeremy D. , Bocks, Martin L. , Boudjemline, Younès , Fagan, Thomas E. , Schubert, Stephan , Mahadevan, Vaikom S. , Dvir, Danny , Osten, Mark , McElhinney, Doff B. , Cabalka, Allison K. , Shah, Ashish H. , McElhinney, Doff B

Catheterization and Cardiovascular Interventions | July 28, 2016 | Volume: 89 | Issue: 2 | Pages: 298-305

10.1002/ccd.26648 Get It

BackgroundThe most common reason for reintervention after a Björk modification of the Fontan procedure, in which the right ventricle (RV) is incorporated into the pulmonary circulation by connecting the right atrial (RA) appendage to the RV directly or with an extra‐anatomic graft, is obstruction or regurgitation of the RA–RV connection. Transcatheter implantation of a valved stent is an appealing option for the treatment of RA–RV conduit dysfunction in these patients. In the present study, we assessed early and intermediate results after transcatheter valve implantation within an obstructed or regurgitant RA–RV modified Fontan pathway.MethodsThrough a retrospective multicenter registry, we collected data from 16 patients with a modified Fontan circulation who were treated with percutaneous Melody or Sapien valve implantation for dysfunction of an extra‐anatomic RA–RV conduit or valve.ResultsAll patients had successful and uncomplicated implantation of a Melody (n = 15) or Sapien 3 (n = 1) valve with hemodynamic and, in most cases, clinical improvement. During a median follow‐up of 3.3 years, 3 patients died of cardiovascular causes unrelated to the procedure or the valve, and no major valve dysfunction was observed.ConclusionPercutaneous transcatheter valve deployment to treat a dysfunctional RA–RV connection after a Björk modification of the Fontan procedure is a viable alternative to surgery, with low procedural risk, and appears to offer good early and intermediate results.© 2016 Wiley Periodicals, Inc.
Transcatheter Tricuspid Valve-in-Valve Implantation for the Treatment of Dysfunctional Surgical Bioprosthetic Valves
McElhinney, Doff B. , Eicken, Andreas , Boudjemline, Younès , Schubert, Stephan , Himbert, Dominique , Asnes, Jeremy D. , Salizzoni, Stefano , Bocks, Martin L. , Momenah, Tarek , Kim, Dennis W. , Schranz, Dietmar, Meadows, Jeffery , Thomson, John , Goldstein, Bryan H. , Crittendon, Ivory, Fagan, Thomas E. , Webb, John G. , Horlick, Eric , Delaney, Jeffrey W., Jones, Thomas K. , Shahanavaz, Shabana , Moretti, Carolina, Hainstock, Michael , Kenny, Damien , Berger, Felix , Rihal, Charanjit S. , Dvir, Danny , Cabalka, Allison K. , Aboulhosn, Jamil A, Cheatham, John P. , Momenah, Tarek S, Thomson, John D R, Hainstock, Michael R, Kenny, Damien P, Aboulhosn, Jamil , Cheatham, John P. , Rihal, Charanjit S. , McElhinney, Doff B , Goldstein, Bryan H

Circulation | March 19, 2016 | Volume: 133 | Issue: 16 | Pages: 1582-1593

10.1161/circulationaha.115.019353 Get It

Background— Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. Methods and Results— An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II ( P <0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. Conclusions— TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.