Back to Authors

Armstrong, Aimee K.

https://orcid.org/0000-0002-4534-5075

Mayo Clinic

Nationwide Children's Hospital

Citations 3

Technical Recommendations for Computed Tomography Guidance of Intervention in the Right Ventricular Outflow Tract: Native RVOT, Conduits, and Bioprosthetic Valves
García, Santiago , Blanke, Phillip, Martin, Mary Hunt , Zahn, Evan M. , Crean, Andrew , Overman, David M. , Hanneman, Kate , Semple, Thomas , Overman, David, Hanneman, Kate , Han, Bo , Aboulhosn, Jamil , Hamilton-Craig, Christian R , Armstrong, Aimee K.

World Journal for Pediatric and Congenital Heart Surgery | August 30, 2023 | Volume: 14 | Issue: 6 | Pages: 761-791

10.1177/21501351231186898 Get It

This consensus document for the performance of cardiovascular computed tomography (CCT) to guide intervention in the right ventricular outflow tract (RVOT) in patients with congenital heart disease (CHD) was developed collaboratively by pediatric and adult interventionalists, surgeons, and cardiac imagers with expertise specific to this patient subset. The document summarizes definitions of RVOT dysfunction as assessed by multimodality imaging techniques and reviews existing consensus statements and guideline documents pertaining to indications for intervention. In the context of this background information, recommendations for CCT scan acquisition and a standardized approach for reporting prior to surgical or transcatheter pulmonary valve replacement are proposed and presented. It is the first Imaging for Intervention collaboration for CHD patients and encompasses imaging and reporting recommendations prior to both surgical and percutaneous pulmonary valve replacement.
Comparison of the investigational device exemption and post‐approval trials of the Melody transcatheter pulmonary valve
Kreutzer, Jacqueline , Armstrong, Aimee K. , Rome, Jonathan J. , Zellers, Thomas M. , Balzer, David T. , Zampi, Jeffrey D. , Javois, Alexander J., Turner, Daniel R. , Gray, Robert G. , Moore, John W. , Weng, Shicheng, Jones, Thomas K. , Khan, Danyal , Vincent, Julie A., Hellenbrand, William E. , Bergersen, Lisa , McElhinney, Doff B. , Cabalka, Allison K. , Gray, Robert G , Moore, John W , Jones, Thomas K , McElhinney, Doff B , Cheatham, John P.

Catheterization and Cardiovascular Interventions | March 29, 2021 | Volume: 98 | Issue: 2 | Pages: No page available

10.1002/ccd.29657 Get It

AbstractObjectiveWe compared 5‐year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post‐approval study (PAS) and the investigational device exemption (IDE) trial.BackgroundAs a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a “real‐world” environment. The 5‐year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared.MethodsThe cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time‐related outcomes and valve‐related adverse events were compared between the two trials with Kaplan–Meier curves and log‐rank testing.Results167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both.ConclusionsHemodynamic and time‐related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real‐world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post‐approval studies as part of the regulatory process for Class III medical devices.
Acute and midterm results following perventricular device closure of muscular ventricular septal defects: A multicenter PICES investigation
Gray, Robert G. , Menon, Shaji C. , Johnson, Joyce T. , Bingler, Michael, Breinholt, John P. , Kenny, Damien , Lozier, John S. , Murphy, Joshua, Sathanandam, Shyam , Taggart, Nathaniel W. , Trucco, Sara M. , Goldstein, Bryan H. , Gordon, Brent M. , Armstrong, Aimee K. , Taggart, Nathaniel W , Goldstein, Bryan H

Catheterization and Cardiovascular Interventions | May 8, 2017 | Volume: 90 | Issue: 2 | Pages: 281-289

10.1002/ccd.27121 Get It

ObjectivesTo describe acute and mid‐term results of hybrid perventricular device closure of muscular ventricular septal defects (mVSDs).BackgroundPerventricular device closure of mVSDs can mitigate technical limitations of percutaneous closure and need for cardiopulmonary bypass or ventriculotomy with a surgical approach.MethodsThis is a multicenter retrospective cohort study of patients undergoing hybrid perventricular mVSD device closure from 1/2004 to 1/2014. Procedural details, adverse events, outcomes, and follow‐up data were collected. Patients were divided into two groups: (1) simple (mVSD closure alone) and (2) complex (mVSD closure with concomitant cardiac surgery).ResultsForty‐seven patients (60% female) underwent perventricular mVSD device closure at a median age of 5.2 months (IQR 1.8–8.9) and weight of 5.1 kg (IQR 4.0–6.9). Procedural success was 91% [100% (n = 22) simple and 84% (n = 21/25) complex]. Adverse events occurred in 19% (9/47) [9% (2/22) simple and 28% (7/25) complex]. Hospital length of stay (LOS) was shorter in the simple vs. complex group (4 vs. 14 days, P < 0.01). At mid‐term follow‐up of 19.2 months (IQR 2.3–43) 90% of pts had complete mVSD closure; none developed late heart block, increased atrioventricular (AV) valve insufficiency or ventricular dysfunction.ConclusionsPerventricular device closure of simple mVSD was associated with a high rate of procedural success, few adverse events, and short hospital LOS. Procedural adverse events were associated with the presence of concomitant complex surgery. Residual mVSD, AV valve insufficiency, or ventricular dysfunction were uncommon at mid‐term follow‐up. © 2017 Wiley Periodicals, Inc.