Back to Authors

Jones, Thomas K

0000-0002-4038-1210

Mayo Clinic

Department of Cardiology, Seattle Children's Hospital, Seattle, Washington, USA.

Citations 2

Midterm Outcomes in a Pooled Cohort of Harmony Transcatheter Pulmonary Valve Recipients
Morray, Brian H. , Gillespie, Matthew J. , Cheatham, John P. , Salavitabar, Arash , Peng, Lynn F., Jones, Thomas K. , Levi, Daniel S. , Gray, Robert G. , Asnes, Jeremy D. , Cabalka, Allison K. , Fujimoto, Kazuto , Qureshi, Athar M. , Bergersen, Lisa, Haugan, Daniel, McElhinney, Doff B. , Asnes, Jeremy D , Benson, Lee N. , McElhinney, Doff B , Jones, Thomas K , Morray, Brian H , Cabalka, Allison , Bergersen, Lisa

Circulation: Cardiovascular Interventions | July 16, 2025 | Volume: 18 | Issue: 9 | Pages: No page available

10.1161/circinterventions.125.015196 Get It

BACKGROUND: The Harmony transcatheter pulmonary valve (TPV) is designed to treat severe pulmonary regurgitation in the native or surgically repaired right ventricular (RV) outflow tract. Early outcomes after TPV replacement with the Harmony valve have been positive, but longer-term data are limited. METHODS: The study included patients who received a commercially available TPV22 or TPV25 device as part of the nonrandomized, prospective Native Outflow Tract Early Feasibility Study, Harmony Pivotal Trial, and Continued Access Study. Patients completed at least 3 years of follow-up, and outcomes to 5 years were reported when available. RESULTS: Eighty-nine patients were catheterized, and 86 were successfully implanted with a Harmony TPV. Median duration of follow-up was 5 (range 0–6) years in the TPV22 group and 3 (1–4) years in the TPV25 group. At 3 years, all patients with a TPV22 and 96% of those with a TPV25 had ≤mild pulmonary regurgitation. By magnetic resonance imaging, significant improvements from preimplant to 2 years were observed in RV end-diastolic volume index, RV to left ventricular end-diastolic volume ratio, and effective RV stroke volume (all P <0.001). SF-36 quality-of-life scores improved after Harmony implantation and were sustained over 3 years. Early cases of ventricular tachycardia resolved, and there were no new arrhythmias. Adverse events up to 5 years included 3 deaths unrelated to the device or procedure, 2 cases of endocarditis that were treated (1 medically, 1 transcatheter debulking of a vegetation) and resolved, 6 patients with RV outflow tract obstruction or thrombosis resulting in valve-in valve procedures, and 1 major stent fracture resulting in surgical explant. CONCLUSIONS: At 3 to 5 years, Harmony TPV replacement resulted in sustained valve competence, beneficial cardiac remodeling, and improved quality of life. Continued monitoring is needed to assess long-term outcomes and valve performance. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT01762124; NCT02979587.
Comparison of the investigational device exemption and post‐approval trials of the Melody transcatheter pulmonary valve
Kreutzer, Jacqueline , Armstrong, Aimee K. , Rome, Jonathan J. , Zellers, Thomas M. , Balzer, David T. , Zampi, Jeffrey D. , Javois, Alexander J., Turner, Daniel R. , Gray, Robert G. , Moore, John W. , Weng, Shicheng, Jones, Thomas K. , Khan, Danyal , Vincent, Julie A., Hellenbrand, William E. , Bergersen, Lisa , McElhinney, Doff B. , Cabalka, Allison K. , Gray, Robert G , Moore, John W , Jones, Thomas K , McElhinney, Doff B , Cheatham, John P.

Catheterization and Cardiovascular Interventions | March 29, 2021 | Volume: 98 | Issue: 2 | Pages: No page available

10.1002/ccd.29657 Get It

AbstractObjectiveWe compared 5‐year outcomes of transcatheter pulmonary valve (TPV) replacement with the Melody TPV in the post‐approval study (PAS) and the investigational device exemption (IDE) trial.BackgroundAs a condition of approval of the Melody TPV after the IDE trial, the Food and Drug Administration required that a PAS be conducted to evaluate outcomes of TPV replacement in a “real‐world” environment. The 5‐year outcomes of the PAS have not been published, and the IDE and PAS trials have not been compared.MethodsThe cohorts comprised all patients catheterized and implanted at 5 IDE sites and 10 PAS sites. Differences in trial protocols were detailed. Time‐related outcomes and valve‐related adverse events were compared between the two trials with Kaplan–Meier curves and log‐rank testing.Results167 patients (median age, 19 years) were catheterized and 150 underwent TPV replacement in the IDE trial; 121 were catheterized (median age, 17 years) and 100 implanted in the PAS. Freedom from hemodynamic dysfunction (p = .61) or any reintervention (p = .74) over time did not differ between trials. Freedom from stent fracture (p = .003) and transcatheter reintervention (p = .010) were longer in PAS, whereas freedom from explant (p = .020) and TPV endocarditis (p = .007) were shorter. Clinically important adverse events (AEs) were reported in 14% of PAS and 7.2% of IDE patients (p = .056); the incidence of any particular event was low in both.ConclusionsHemodynamic and time‐related outcomes in the PAS and IDE trials were generally similar, confirming the effectiveness of the Melody TPV with real‐world providers. There were few significant complications and limited power to identify important differences in AEs. The lack of major differences in outcomes between the two studies questions the usefulness of mandated costly post‐approval studies as part of the regulatory process for Class III medical devices.