Back to Authors

Shahanavaz, Shabana

https://orcid.org/0000-0003-1620-9709

Mayo Clinic

Cincinnati Children's Hospital Medical Center

Citations 2

Feasibility of intentional bioprosthetic valve fracture in the tricuspid position
Hagel, Jonathon A. , Qureshi, Athar M. , Tanase, Daniel , Eicken, Andreas , Zampi, Jeffrey D. , Cabalka, Allison K. , Anderson, Jason H. , Shahanavaz, Shabana , Qureshi, Athar M , Tanase, Daniel , Zampi, Jeffrey D , Cabalka, Allison , Anderson, Jason , Lin, C. Huie

Catheterization and Cardiovascular Interventions | August 1, 2024 | Volume: 104 | Issue: 3 | Pages: 523-530

10.1002/ccd.31168 Get It

AbstractBackgroundTranscatheter tricuspid valve‐in‐valve (ViV) replacement has yielded good hemodynamic outcomes in the treatment of dysfunctional bioprosthetic valves (BPVs). Intentional fracture of certain rigid BPV frames, if feasible, allows a larger implanted valve when compared with implant into an unfractured BPV. There remains limited data on the feasibility of tricuspid valve frame fracture.AimsEvaluate the feasibility of transcatheter tricuspid ViV replacement with fracture of the underlying BPV ring.MethodsAn international multicenter registry of tricuspid ViV replacement with intentional tricuspid valve frame fracture was created. Demographic data along with procedural characteristics, outcomes, and follow‐up data were collected. Comparison was made to the pre‐ and post‐ViV replacement with fracture of the tricuspid valve frame conditions.ResultsTen patients from six centers were included with a median age and weight of 29 years and 67.3 kg respectively. Tricuspid valve frame fracture was performed using a median balloon diameter 3 mm (IQR 3–5) larger than the true inner diameter (ID). The final ID was a mean of 1.5 mm (95% CI: 0.35, 2.64: p < 0.05), and median 1.1 mm (0.5, 2.1) larger than the reported true ID of the surgical BPV after ViV replacement. The mean tricuspid inflow gradient by echocardiogram decreased by 6.65 mmHg (95% CI: 4.14, 9.15: p < 0.001). All procedures were without complication, specifically there was no heart block, pericardial effusion, or right coronary disruption.ConclusionIntentional tricuspid valve frame fracture with tricuspid ViV replacement is feasible and can increase the valve orifice potentially reducing the risk of ViV patient prosthesis mismatch and is not associated with significant complications.
Transcatheter Tricuspid Valve-in-Valve Implantation for the Treatment of Dysfunctional Surgical Bioprosthetic Valves
McElhinney, Doff B. , Eicken, Andreas , Boudjemline, Younès , Schubert, Stephan , Himbert, Dominique , Asnes, Jeremy D. , Salizzoni, Stefano , Bocks, Martin L. , Momenah, Tarek , Kim, Dennis W. , Schranz, Dietmar, Meadows, Jeffery , Thomson, John , Goldstein, Bryan H. , Crittendon, Ivory, Fagan, Thomas E. , Webb, John G. , Horlick, Eric , Delaney, Jeffrey W., Jones, Thomas K. , Shahanavaz, Shabana , Moretti, Carolina, Hainstock, Michael , Kenny, Damien , Berger, Felix , Rihal, Charanjit S. , Dvir, Danny , Cabalka, Allison K. , Aboulhosn, Jamil A, Cheatham, John P. , Momenah, Tarek S, Thomson, John D R, Hainstock, Michael R, Kenny, Damien P, Aboulhosn, Jamil , Cheatham, John P. , Rihal, Charanjit S. , McElhinney, Doff B , Goldstein, Bryan H

Circulation | March 19, 2016 | Volume: 133 | Issue: 16 | Pages: 1582-1593

10.1161/circulationaha.115.019353 Get It

Background— Off-label use of transcatheter aortic and pulmonary valve prostheses for tricuspid valve-in-valve implantation (TVIV) within dysfunctional surgical tricuspid valve (TV) bioprostheses has been described in small reports. Methods and Results— An international, multicenter registry was developed to collect data on TVIV cases. Patient-related factors, procedural details and outcomes, and follow-up data were analyzed. Valve-in-ring or heterotopic TV implantation procedures were not included. Data were collected on 156 patients with bioprosthetic TV dysfunction who underwent catheterization with planned TVIV. The median age was 40 years, and 71% of patients were in New York Heart Association class III or IV. Among 152 patients in whom TVIV was attempted with a Melody (n=94) or Sapien (n=58) valve, implantation was successful in 150, with few serious complications. After TVIV, both the TV inflow gradient and tricuspid regurgitation grade improved significantly. During follow-up (median, 13.3 months), 22 patients died, 5 within 30 days; all 22 patients were in New York Heart Association class III or IV, and 9 were hospitalized before TVIV. There were 10 TV reinterventions, and 3 other patients had significant recurrent TV dysfunction. At follow-up, 77% of patients were in New York Heart Association class I or II ( P <0.001 versus before TVIV). Outcomes did not differ according to surgical valve size or TVIV valve type. Conclusions— TVIV with commercially available transcatheter prostheses is technically and clinically successful in patients of various ages across a wide range of valve size. Although preimplantation clinical status was associated with outcome, many patients in New York Heart Association class III or IV at baseline improved. TVIV should be considered a viable option for treatment of failing TV bioprostheses.