Transcatheter closure of a native mitral valve following mitral valve bypass surgery using a novel left atrial-to-left ventricle conduit-associated arteriovenous rail
AbstractObjectivesThe aim of this study was to determine the safety of eliminating the pre‐discharge transthoracic echocardiogram (TTE) on 30‐day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR).BackgroundTTE is utilized before, during, and after TAVR. Post‐procedural, pre‐discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR.MethodsPatients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre‐discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post‐TAVR.ResultsA total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre‐discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre‐discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre‐discharge TTE group and none in the group without pre‐discharge TTE at 30‐day follow‐up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre‐discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71).ConclusionsElimination of the pre‐discharge TTE is safe and associated with comparable 30‐day outcomes to routine pre‐discharge TTE. These findings have implication for TAVR practice cost‐efficiency and health care utilization.
Temporal Incidence and Predictors of High‐Grade Atrioventricular Block After Transcatheter Aortic Valve Replacement
Background The temporal incidence of high‐grade atrioventricular block (HAVB) after transcatheter aortic valve replacement (TAVR) is uncertain. As a result, periprocedural monitoring and pacing strategies remain controversial. This study aimed to describe the temporal incidence of initial episode of HAVB stratified by pre‐ and post‐TAVR conduction and identify predictors of delayed events. Methods and Results Consecutive patients undergoing TAVR at a single center between February 2012 and June 2019 were retrospectively assessed for HAVB within 30 days. Patients with prior aortic valve replacement, permanent pacemaker (PPM), or conversion to surgical replacement were excluded. Multivariable logistic regression was performed to assess predictors of delayed HAVB (initial event >24 hours post‐TAVR). A total of 953 patients were included in this study. HAVB occurred in 153 (16.1%). After exclusion of those with prophylactic PPM placed post‐TAVR, the incidence of delayed HAVB was 33/882 (3.7%). Variables independently associated with delayed HAVB included baseline first‐degree atrioventricular block or right bundle‐branch block, self‐expanding valve, and new left bundle‐branch block. Forty patients had intraprocedural transient HAVB, including 16 who developed HAVB recurrence and 6 who had PPM implantation without recurrence. PPM was placed for HAVB in 130 (13.6%) (self‐expanding valve, 23.7% versus balloon‐expandable valve, 11.9%; P <0.001). Eight (0.8%) patients died by 30 days, including 1 unexplained without PPM present. Conclusions Delayed HAVB occurs with higher frequency in patients with baseline first‐degree atrioventricular block or right bundle‐branch block, new left bundle‐branch block, and self‐expanding valve. These findings provide insight into optimal monitoring and pacing strategies based on periprocedural ECG findings.
Effect of a fourth‐generation transcatheter valve enhanced skirt on paravalvular leak
AbstractObjectivesThe aim of this study was to assess the 30 day incidence of paravalvular leak (PVL) and need for aortic valve reintervention of a fourth generation balloon expandable transcatheter valve with enhanced skirt (4G‐BEV) (SAPIEN 3 Ultra) compared with a third generation balloon expandable transcatheter valve (3G‐BEV) (SAPIEN 3).BackgroundThe incidence of PVL has steadily declined with iterative improvements in transcatheter aortic valve replacement (TAVR) technology and implantation strategies.MethodsPatients who underwent TAVR at Mayo Clinic from 7/2018 to 7/2019 were included in a prospective institutional registry. 4G‐BEV has been utilized since 2/2019, and, after this date, 3G‐BEV and 4G‐BEV were simultaneously used. 4G‐BEV had three sizes (20, 23, and 26 mm) while 3G‐BEV included four sizes (20, 23, 26, and 29 mm). Both cohorts were evaluated at 30 days post‐TAVR with a transthoracic echocardiogram to assess for PVL.ResultsA total of 260 consecutive patients were included. Of these, 101 patients received a 4G‐BEV and 159 patients received a 3G‐BEV. There were more females (p = .0005) and a lower aortic valve calcium score (p = .02) in the 4G‐BEV cohort at baseline. Age, STS risk score, NYHA Class, and aortic valve mean gradient did not differ between groups. 4G‐BEV was associated with a lower incidence of mild PVL (10.8 vs. 36.5%; p < .0001) and moderate PVL (0 vs. 5.8%) compared to the 3G‐BEV at 30 days. There was no association between PVL and valve size in either cohort.ConclusionsUtilization of 4G‐BEV is associated with reduced PVL at 30 days post‐TAVR compared with 3G‐BEV.
Incidence, Characteristics, and Outcomes of Acute Myocardial Infarction among Patients Admitted with Acute Exacerbation of Chronic Obstructive Lung Disease