Abstract Aims Lipoprotein(a) [Lp(a)] has demonstrated its association with atherosclerosis and myocardial infarction. However, its role in the development of in-stent restenosis (ISR) after percutaneous coronary intervention (PCI) is not clearly established. The aim of this study is to investigate the association between Lp(a) and ISR. Methods and results A retrospective study of adult patients who underwent successful PCI between January 2006 and December 2017 at the three Mayo Clinic sites and had a preprocedural Lp(a) measurement was conducted. Patients were divided into two groups according to the serum Lp(a) concentration [high Lp(a) ≥ 50 mg/dL and low Lp(a) < 50 mg/dL]. Univariable and multivariable analyses were performed to compare risk of ISR between patients with high Lp(a) vs. those with low Lp(a). A total of 1209 patients were included, with mean age 65.9 ± 11.7 years and 71.8% were male. Median follow-up after baseline PCI was 8.8 [interquartile range (IQR) 7.4] years. Restenosis was observed in 162 (13.4%) patients. Median serum levels of Lp(a) were significantly higher in patients affected by ISR vs. non-affected cases: 27 (IQR 73.8) vs. 20 (IQR 57.5) mg/dL, P = 0.008. The rate of ISR was significantly higher among patients with high Lp(a) vs. patients with low Lp(a) values (17.0% vs. 11.6%, P = 0.010). High Lp(a) values were independently associated with ISR events (hazard ratio 1.67, 95% confidence interval 1.18–2.37, P = 0.004), and this association was more prominent after the first year following the PCI. Conclusion Lipoprotein(a) is an independent predictor for long-term ISR and should be considered in the evaluation of patients undergoing PCI.
AbstractObjectivesTo compare all‐cause mortality in patients with mitral annulus calcification (MAC) and severe mitral valve dysfunction (MVD) who received standard mitral intervention versus no intervention.BackgroundPatients with MAC often have high surgical risk due to advanced age, comorbidities, and technical challenges related to calcium. The impact of a mitral intervention on outcomes of patients with MAC and severe MVD is not well known.MethodsRetrospective review of patients with MAC by transthoracic echocardiography (TTE) in 2015 at a single institution. Patients with severe mitral stenosis (MS) or regurgitation (MR) were analyzed and stratified into two groups: surgical or transcatheter intervention performed <1 year after the index TTE, and no or later intervention. The primary endpoint was all‐cause mortality.ResultsOf 5502 patients with MAC, 357 had severe MVD (MS = 27%, MR = 73%). Of those, 108 underwent mitral intervention (surgery = 87; transcatheter = 21). They were younger (73 ± 11 vs. 76 ± 11 years, p < 0.01) and less frequently had cardiovascular diseases compared with no‐intervention. Frequency in women was similar (45% vs. 50%, p = 0.44). During median follow‐up of 3.2 years, the intervention group had higher estimated survival than those without intervention (80% vs. 72% at 1 year and 55% vs. 35% at 4 year, p < 0.01). Adjusted for age, eGFR, LVEF < 50%, and pulmonary hypertension, mitral intervention was an independent predictor of lower mortality (hazard ratio = 0.66, 95% confidence interval 0.43–0.99, p = 0.046).ConclusionPatients with MAC and severe MVD who underwent mitral intervention <1 year from index TTE had lower mortality than those without intervention. Mitral intervention was independently associated with lower mortality.
Impact of blood pressure on coronary perfusion and valvular hemodynamics after aortic valve replacement
Abstract Objective Our objective was to evaluate the impact of various blood pressures (BPs) on coronary perfusion and valvular hemodynamics following aortic valve replacement (AVR). Background Lower systolic and diastolic (SBP/DBP) pressures from the recommended optimal target range of SBP < 120–130 mmHg and DBP < 80 mmHg after AVR have been independently associated with increased cardiovascular and all‐cause mortality. Methods The hemodynamic assessment of a 26 mm SAPIEN 3 transcatheter aortic valve (TAV), 29 mm Evolut R TAV, and 25 mm Magna Ease surgical aortic valve (SAV) was performed in a pulsed left heart simulator with varying SBP, DBP, and heart rate (HR) conditions (60 and 120 bpm) at 5 L/min cardiac output (CO). Average coronary flow (CF), effective orifice areas (EOAs), and valvulo‐arterial impedance (Zva) were calculated. Results At HR of 60 bpm, at SBP < 120 mmHg and DBP < 60 mmHg, CF decreased below the physiological lower limit with several different valves. Zva and EOA were found to increase and decrease respectively with increasing SBP and DBP. The same results were found with an HR of 120 bpm. The trends of CF variation with BP were similar in all valves however the drop below the lower physiological CF limit was valve dependent. Conclusion In a controlled in vitro system, with different aortic valve prostheses in place, CF decreased below the physiologic minimum when SBP and DBP were in the range targeted by blood pressure guidelines. Combined with recent observations from patients treated with AVR, these findings underscore the need for additional studies to identify the optimal BP in patients treated with AVR for AS.
Effect of eliminating pre‐discharge transthoracic echocardiogram on outcomes after TAVR
AbstractObjectivesThe aim of this study was to determine the safety of eliminating the pre‐discharge transthoracic echocardiogram (TTE) on 30‐day outcomes in patients undergoing transcatheter aortic valve replacement (TAVR).BackgroundTTE is utilized before, during, and after TAVR. Post‐procedural, pre‐discharge TTE assists in assessment of prosthesis function and detection of clinically significant paravalvular leak (PVL) after TAVR.MethodsPatients who underwent TAVR at Mayo Clinic from July 2018 to July 2019 were included in a prospective institutional registry. Patients undergoing TAVR prior to February 2019 received a pre‐discharge TTE, while those undergoing TAVR after February 2019 did not. Both cohorts were evaluated with TTE at 30 days post‐TAVR.ResultsA total of 330 consecutive patients were included. Of these, 160 patients (age 81.1 ± 7.6) had routine pre‐discharge TTE, while 170 patients (age 78.9 ± 7.5) were dismissed without routine pre‐discharge TTE. Mortality at 30 days was similar between the two groups (0% and 1.2%, respectively). One episode of PVL requiring intervention (0.6%) occurred in the pre‐discharge TTE group and none in the group without pre‐discharge TTE at 30‐day follow‐up. There was a similar incidence of total composite primary and secondary adverse events between the cohort receiving a pre‐discharge TTE and those without (28.1% vs. 25.3%, P = 0.56) at 30 days. The most common event was need for permanent pacemaker or ICD implantation in both groups (13.1% vs. 11.8%, P = 0.71).ConclusionsElimination of the pre‐discharge TTE is safe and associated with comparable 30‐day outcomes to routine pre‐discharge TTE. These findings have implication for TAVR practice cost‐efficiency and health care utilization.
Temporal outcomes of transcatheter mitral valve replacement in native mitral valve disease with annular calcification
Catheterization and Cardiovascular Interventions | February 8, 2021 | Volume: No volume available | Issue: No issue available | Pages: No page available
AbstractObjectivesThe aim of this study was to assess the 30 day incidence of paravalvular leak (PVL) and need for aortic valve reintervention of a fourth generation balloon expandable transcatheter valve with enhanced skirt (4G‐BEV) (SAPIEN 3 Ultra) compared with a third generation balloon expandable transcatheter valve (3G‐BEV) (SAPIEN 3).BackgroundThe incidence of PVL has steadily declined with iterative improvements in transcatheter aortic valve replacement (TAVR) technology and implantation strategies.MethodsPatients who underwent TAVR at Mayo Clinic from 7/2018 to 7/2019 were included in a prospective institutional registry. 4G‐BEV has been utilized since 2/2019, and, after this date, 3G‐BEV and 4G‐BEV were simultaneously used. 4G‐BEV had three sizes (20, 23, and 26 mm) while 3G‐BEV included four sizes (20, 23, 26, and 29 mm). Both cohorts were evaluated at 30 days post‐TAVR with a transthoracic echocardiogram to assess for PVL.ResultsA total of 260 consecutive patients were included. Of these, 101 patients received a 4G‐BEV and 159 patients received a 3G‐BEV. There were more females (p = .0005) and a lower aortic valve calcium score (p = .02) in the 4G‐BEV cohort at baseline. Age, STS risk score, NYHA Class, and aortic valve mean gradient did not differ between groups. 4G‐BEV was associated with a lower incidence of mild PVL (10.8 vs. 36.5%; p < .0001) and moderate PVL (0 vs. 5.8%) compared to the 3G‐BEV at 30 days. There was no association between PVL and valve size in either cohort.ConclusionsUtilization of 4G‐BEV is associated with reduced PVL at 30 days post‐TAVR compared with 3G‐BEV.