Back to Authors

Kaplan, Revelee

Mayo Clinic

Mayo Clinic

Citations 2

Routine Continuous Electrocardiographic Monitoring Following Percutaneous Coronary Interventions
Al‐Hijji, Mohammed , Gulati, Rajiv , Bell, Malcolm R. , Kaplan, Revelee J., Feind, Jeanna L., Lewis, Bradley R., Moriarty, James P. , Park, Jae Yoon , Sabbagh, Abdallah El , Kanwar, Ardaas, Barsness, Gregory W. , Munger, Thomas M. , Asirvatham, Samuel J. , Al-Hijji, Mohammed A , Bell, Malcolm, Borah, Bijan J. , Yoon Park, Jae, Barsness, Gregory, Munger, Thomas, Asirvatham, Samuel J , Kaplan, Revelee, Lerman, Amir , Singh, Mandeep

Circulation: Cardiovascular Interventions | December 30, 2019 | Volume: 13 | Issue: 1 | Pages: No page available

10.1161/circinterventions.119.008290 Get It

Background: The clinical utility of routine electrocardiographic monitoring following percutaneous coronary interventions (PCI) is not well studied. Methods: We prospectively evaluated the incidence, cost, and the clinical implications of actionable arrhythmia alarms on telemetry monitoring following PCI. One thousand three hundred fifty-eight PCI procedures (989 [72.8%] for acute coronary syndrome and 369 [27.2%] for stable angina) on patients admitted to nonintensive care unit were identified and divided into 2 groups; group 1, patients with actionable alarms (AA) and group 2, patients with non-AA. AA included (1) ≥3 s electrical pause or asystole; (2) high-grade Mobitz type II atrioventricular block or complete heart block; (3) ventricular fibrillation; (4) ventricular tachycardia (>15 beats); (5) atrial fibrillation with rapid ventricular response; (6) supraventricular tachycardia (>15 beats). Primary outcomes were 30-day all-cause mortality. Cost-savings analysis was performed. Results: Incidence of AA was 2.2% (37/1672). Time from end of procedure to AA was 5.5 (0.5, 24.5) hours. Patients with AA were older, presented with acute congestive heart failure or non–ST-segment–elevation myocardial infarction, and had multivessel or left main disease. The 30-day all-cause mortality was significantly higher in patients with AA (6.5% versus 0.3% in non-AA [ P <0.001]). Applying the standardized costing approach and tailored monitoring per the American Heart Association guidelines lead to potential cost savings of $622 480.95 for the entire population. Conclusions: AA following PCI were infrequent but were associated with increase in 30-day mortality. Following American Heart Association guidelines for monitoring after PCI can lead to substantial cost saving.
Real-time remote physiological monitoring
Ardoin, Wil-Johneen, Hoyle, W. Sloane, Bewaji, Oluwatosin, Ferris, Thomas K. , Peres, S. Camille , Kaplan, Revelee, Brady, Peter A. , Ardoin, Wil-Johneen, Bewaji, Oluwatosin, Hallbeck, M. Susan

Proceedings of the Human Factors and Ergonomics Society Annual Meeting | September 15, 2016 | Volume: 60 | Issue: 1 | Pages: 618-622

10.1177/1541931213601141 Get It

Researchers at a large Midwest Tertiary Care Hospital have developed a remote monitoring system that supports 24-hour real-time physiological monitoring of multiple noncritical care patients from a central remote display station. The system’s potential to revolutionize the healthcare industry has encouraged future plans to expand the operation. However, all of the system’s characteristics and how those characteristics interact to affect qualities of interest such as worker efficiency, fatigue, and patient care have not been fully explored. A mixed-methods ethnographic approach was used to identify and more comprehensively understand characteristics of the remote monitoring systems currently in place. Analyses described three remote monitoring paradigms, emphasizing elements of communication that were perceived to impact patient care. These efforts are the first steps in continued analyses of remote monitoring systems and are important in the identification of key system elements intended to construct a fundamental remote monitoring model.