Summary Background Stricturing Crohn's disease (CD) occurs most commonly in the terminal ileum and poses a clinical problem. Cross‐sectional imaging modalities such as intestinal ultrasound (IUS), computed tomography enterography (CTE), and magnetic resonance enterography (MRE) allow for assessment of the entire bowel wall and associated peri‐enteric findings. Radiologic definitions of strictures have been developed for CTE and MRE; their reliability and responsiveness are being evaluated in index development programs. A comprehensive assessment strategy for strictures using IUS is needed. Aims To provide a detailed summary of definitions, diagnosis and monitoring of strictures on IUS as well as technical aspects of image acquisition. Methods We searched four databases up to 6 January 2024. Two‐stage screening was done in duplicate. We assessed risk of bias using QUADAS‐2. Results There were 56 studies eligible for inclusion. Definitions for strictures on IUS are heterogeneous, but the overall accuracy for diagnosis of strictures is high. The capability of IUS for characterising inflammation versus fibrosis in strictures is not accurate enough to be used in clinical practice or trials. We summarise definitions for improvement of strictures on IUS, and discuss parameters for image acquisition and standardisation. Conclusions This systematic review is the first step for a structured program to develop a stricture IUS index for CD.
Lymphatic Mapping Using US Microbubbles before Lymphaticovenous Anastomosis Surgery for Lymphedema
Gallbladder carcinoma is rare and difficult to detect in the early stages of the disease process, due to lack of symptoms. Sonography is typically the first modality of choice for assessing gallbladder pathology due to its high sensitivity, portability, real-time imaging capability, and non-ionizing technique. Conventional gray-scale and color Doppler sonographic imaging may be ambiguous for diagnosing solid tumors, such as gallbladder carcinoma. In this case, gallbladder carcinoma was definitively diagnosed utilizing contrast-enhanced ultrasound, allowing for quick patient treatment options and an optimal surgical outcome.
Three-Dimensional-Printed Liver Model Helps Learners Identify Hepatic Subsegments: A Randomized-Controlled Cross-Over Trial
INTRODUCTION: The purpose of this study was to find out whether 3-dimensional (3D)–printed models improved the learners' ability to identify liver segments. METHODS: A total of 116 physicians from 3 disciplines were tested in a cross-over trial at baseline and after teaching with 3D models and 2-dimensional (2D) images. Adjusted multilevel-mixed models were used to compare scores at baseline and after 3D and 2D. RESULTS: Accuracy in identifying hepatic segments was higher with 3D first than 2D (77% vs 69%; P = 0.05) and not significantly improved by a combination of 3D and 2D. Increased confidence in segment identification was highest in trainees after 3D ( P = 0.04). DISCUSSION: 3D-printed models facilitate learning hepatic segmental anatomy.
Quantitative Inflammation Assessment for Crohn Disease Using Ultrasensitive Ultrasound Microvessel Imaging
ObjectivesCrohn disease (CD) is a chronic inflammation in the digestive tract that affects millions of Americans. Bowel vascularity has important diagnostic information because inflammation is associated with blood flow changes. We recently developed an ultrasensitive ultrasound microvessel imaging (UMI) technique with high vessel sensitivity. This study aimed to evaluate the feasibility of UMI to assist CD detection and staging.MethodsUltrasound microvessel imaging was performed on 76 bowel wall segments from 48 symptomatic patients with CD. Clinically indicated computed tomographic/magnetic resonance enterography was used as the reference standard. The vessel‐length ratio (VLR, the number of vessel pixels in the bowel wall segment normalized to the segment length) was derived in both conventional color flow imaging (CFI) and UMI to quantitatively stage disease activity. Receiver operating characteristic curves were then analyzed between different disease groups.ResultsThe VLR‐CFI and VLR‐UMI detected similar correlations between vascularization and disease activity: severe inflammation had a higher VLR than normal/mildly inflamed bowels (P < .05). No significant difference was found between quiescent and mild CD due to the small sample size. The VLR‐CFI had more difficulties in distinguishing quiescent versus mild CD compared to the VLR‐UMI. After combining the VLR‐UMI with thickness, in the receiver operating characteristic curve analysis, the areas under the curves (AUCs) improved to AUC1 = 0.996 for active versus quiescent CD, AUC2 = 0.978 for quiescent versus mild CD, and AUC3 = 0.931 for mild versus severe CD, respectively, compared to those using thickness alone (AUC1 = 0.968; P = .04; AUC2 = 0.919; P = .16; AUC3 = 0.857; P = .01).ConclusionsUltrasound microvessel imaging offers a safe and cost‐effective tool for CD diagnosis and staging, which may potentially assist disease activity classification and therapy efficacy evaluation.
Racial and Ethnic Disparities in the Utilization of Thrombectomy for Acute Stroke
Background and Purpose— Racial and ethnic disparities in the access to mechanical thrombectomy (MT) for treatment of acute ischemic stroke (AIS) secondary to large vessel occlusion have been previously described. The effect of recent randomized trials validating MT as an effective therapy for AIS secondary to large vessel occlusion on such disparities has not been investigated. Methods— Information on admissions for AIS to endovascular centers occurring between January 2016 and September 2018 was obtained from a national database. The number of patients receiving IV-tPA (intravenous tissue-type plasminogen activator) and MT at each institution was determined, and patient demographics were characterized according to age, sex, race/ethnicity, and insurance status. Comparisons of patients who did and did not undergo MT and between patients of different racial and ethnic backgrounds were performed. Demographic variables independently associated with the utilization of MT were identified using multivariate linear regression analysis. Results— There were 206 853 admissions to 173 endovascular centers during the time period of interest. The overall utilization of MT was 8.4%. The utilization of MT for black/Hispanic patients was lower than that among white/non-Hispanic patients (7.0% versus 9.8%; P <0.001). Black/Hispanic patients were also less likely to receive IV-tPA (16.2% versus 20.5%; P <0.001) and to be admitted to the endovascular center after transfer from a different hospital (20.0% versus 30.1%; P <0.001). On multivariate linear regression analysis, increasing institutional proportions of patients with female sex (β=−0.601; P <0.001), insurance with Medicaid or uninsured status (β=−0.153; P =0.029), and black/Hispanic race/ethnicity (β=−0.062; P =0.046) were independently associated with lower institutional utilization of MT. Conclusions— Despite the mainstream acceptance of MT for the treatment of AIS secondary to large vessel occlusion, racial and ethnic disparities in the utilization of MT persist.
Anaphylactic reaction to an ultrasound contrast agent (Lumason) in a patient with systemic mastocytosis
AbstractSevere adverse reactions to ultrasound (US) contrast agents are rare, and only a few cases of anaphylaxis following the administration of US contrast agents have been reported, often without a defined etiology. We present a case of anaphylactic reaction to the injection of an US contrast agent in a patient with systemic mastocytosis, which highlights the disorder as a possible risk factor warranting additional consideration prior to performing a contrast‐enhanced US examination.
Prospective Assessment of Dynamic CT and MR Cholangiography in Functional Biliary Pain