Back to Authors

Taylor, Stuart A.

https://orcid.org/0000-0002-6765-8806

Mayo Clinic

University College London

Citations 7

P0238 Reliability of magnetic resonance imaging indices for evaluating perianal fistulizing disease activity in paediatric Crohn’s disease
Karpewycz, John , Watson, Tom A. , Schneider, R, Alsabban, Zehour , Cytter-Kuint, Ruth, Lewindon, Peter , Gee, Michael S. , Hyams, J S, Allmen, Daniel von, Overstraeten, Anthony de Buck van , Shackelton, L, Rémillard, J, Ashton, H A, Taylor, Stuart A. , Church, Peter, Feagan, B, Griffiths, A, Crowley, Eileen , Rimola, Jordi , Schneider, R, Ma, Christopher , Zou, Guangyong , Gee, Michael Stanley , Rosen, Michael J. , Ashton, H, Dillman, Jonathan R , Fletcher, Joel G. , Church, Peter , Jairath, Vipul , Greer, Mary‐Louise C.

Journal of Crohn's and Colitis | January 22, 2025 | Volume: 19 | Issue: Supplement_1 | Pages: i660-i661

10.1093/ecco-jcc/jjae190.0412 Get It

Abstract Background Progress in clinical trials and drug development for paediatric perianal fistulising CD (pfCD) depends upon accurate, reproducible imaging to assess disease activity and measure treatment response. We evaluated the inter- and intra-rater reliability of existing radiologic disease activity indices and anatomical classification systems previously identified as appropriate for assessment of paediatric pfCD.1 Methods A retrospective cohort (N=50) of magnetic resonance imaging (MRI) exams representing a full spectrum of paediatric (<18 years) perianal CD severity was selected by a single expert paediatric radiologist. Methods described by Zou2 were used to estimate sample size. Three separate radiologists (2 paediatric) blinded to clinical information assessed pfCD in the exams using the Magnetic Resonance Novel Index for Fistula Imaging in CD (MAGNIFI-CD), Van Assche Index (VAI), modified VAI (mVAI), Paediatric MRI based Perianal Crohn’s disease (PEMPAC) index, a visual analogue scale (VAS) of overall pfCD disease severity (range, 0-100 mm), as well as with the Park’s and St. James University Hospital anatomic classification systems. Two radiologists read all exams twice, separated by 2 weeks, and 1 radiologist read the exams once (250 total reads). Intra- and inter-rater reliability was evaluated using intraclass correlation coefficients (ICC; equivalent to weighted kappa). Precision of the ICC estimates was quantified with 95% confidence intervals (CIs) obtained using clustered bootstrapping. Degree of reliability was interpreted with benchmarks proposed by Landis and Koch3. Results Median age of children was 13.5 years (IQR 11.4-16.1), and 64% were male. Median Paediatric Crohn’s Disease Activity Index score at time of imaging was 17.5 (IQR 10-32.5). Substantial (ICC>0.61) inter-rater reliability was observed for MAGNIFI-CD, VAI, and mVAI (Table 1), with the highest ICCs observed for the mVAI (0.72 [0.6 to 0.79]). Moderate (ICC>0.41) inter-rater reliability was observed for PEMPAC, St. James University Hospital classification, and the VAS, and fair (ICC>0.21) inter-rater reliability was observed for Parks classification. Intra-rater reliability was nearly perfect (ICC>0.81) for the VAS, and substantial for all indices except for Parks classification, which had moderate (0.60 [0.44 to 0.75]) intra-rater reliability (Table 1). Conclusion Most existing multi-item MRI-based disease activity indices and the St. James Hospital classification were reliable for the assessment of paediatric pfCD in our cohort. Our preliminary results suggest that the disease activity indices may have utility to measure treatment effect in paediatric pfCD clinical trials. References 1.Crowley E, Ma C, Guizzetti L, Zou G, Lewindon PJ, Gee MS, et al. Recommendations for Standardizing MRI-based Evaluation of Perianal Fistulizing Disease Activity in Pediatric Crohn's Disease Clinical Trials. Inflamm Bowel Dis. 2024;30(3):357-69. 2.Zou GY. Sample size formulas for estimating intraclass correlation coefficients with precision and assurance. Statistics in Medicine. 2012;31(29):3972-398 3.Landis JR, Koch GG. The measurement of observer agreement for categorical data. Biometrics. 1977;33(1):159-74.
Systematic review: Defining, diagnosing and monitoring small bowel strictures in Crohn's disease on intestinal ultrasound
Lu, Cathy , Rosentreter, Ryan E., Delisle, Maxime , White, Mattie, Parker, Claire E. , Premji, Zahra , Baker, Mark E. , Bhatnagar, Gauraang , Begun, Jakob , Bruining, David H. , Bryant, Robert V. , Christensen, Britt , Feagan, Brian G. , Jairath, Vipul , Knudsen, John M. , Kucharzik, Torsten , Maaser, Christian , Novak, Kerri L. , Taylor, Stuart A. , Wilkens, Rune , Rieder, Florian , Jairath, Vipul , Jairath, Vipul , Begun, Jakob , Bryant, Robert, Christensen, Britt , Jairath, V , Knudsen, John, Maconi, Giovanni , Novak, Kerri , Wilkens, Rune , Rieder, Florian , Lu, Cathy , Jairath, V , Jairath, Vipul , Wilson, Stephanie R. , Fletcher, Joel G. , Rimola, Jordi

Alimentary Pharmacology & Therapeutics | March 4, 2024 | Volume: 59 | Issue: 8 | Pages: 928-940

10.1111/apt.17918 Get It

Summary Background Stricturing Crohn's disease (CD) occurs most commonly in the terminal ileum and poses a clinical problem. Cross‐sectional imaging modalities such as intestinal ultrasound (IUS), computed tomography enterography (CTE), and magnetic resonance enterography (MRE) allow for assessment of the entire bowel wall and associated peri‐enteric findings. Radiologic definitions of strictures have been developed for CTE and MRE; their reliability and responsiveness are being evaluated in index development programs. A comprehensive assessment strategy for strictures using IUS is needed. Aims To provide a detailed summary of definitions, diagnosis and monitoring of strictures on IUS as well as technical aspects of image acquisition. Methods We searched four databases up to 6 January 2024. Two‐stage screening was done in duplicate. We assessed risk of bias using QUADAS‐2. Results There were 56 studies eligible for inclusion. Definitions for strictures on IUS are heterogeneous, but the overall accuracy for diagnosis of strictures is high. The capability of IUS for characterising inflammation versus fibrosis in strictures is not accurate enough to be used in clinical practice or trials. We summarise definitions for improvement of strictures on IUS, and discuss parameters for image acquisition and standardisation. Conclusions This systematic review is the first step for a structured program to develop a stricture IUS index for CD.
Ein globaler Consensus zu Definitionen, Diagnostik und Behandlungsmanagement des fibrostenotischen Morbus Crohn des terminalen Ileums
Baker, Mark E. , Bemelman, Willem A. , D’Haens, Geert , D’Hoore, A., Feakins, Roger , Fleshner, Phillip , Ha, Christina , Lyu, R., Mao, Ren , Sandborn, William J. , Ng, S, Silverberg, Mark S. , Bruining, David H. , Feagan, Brian G. , Bettenworth, Dominik , Fletcher, Joel G. , Jairath, Vipul , Lu, Cathy , Dignass, Axel , Dotan, Iris , Henderson, G., Panés, Julián , Rogler, Gerhard , Rimola, Jordi , Siegmund, Britta , Taylor, Stuart A. , Verstockt, Bram , Gordon, Ilyssa O. , Rieder, F.

Zeitschrift für Gastroenterologie | October 26, 2023 | Volume: 61 | Issue: 08 | Pages: e421-e422

10.1055/s-0043-1771750 Get It

Recommendations for Standardizing MRI-based Evaluation of Perianal Fistulizing Disease Activity in Pediatric Crohn’s Disease Clinical Trials
Crowley, Eileen , Ma, Christopher , Guizzetti, Leonard, Lewindon, Peter , Gee, Michael S. , Hyams, Jeffrey S. , Rosen, Michael J. , Allmen, Daniel von, Overstraeten, Anthony de Buck van , Shackelton, Lisa M. , Rémillard, Julie, Schleicher, Lauren S., Rimola, Jordi , Taylor, Stuart A. , Church, Peter , Feagan, Brian G. , Jairath, Vipul , Jairath, Vipul , Jairath, Vipul , Hyams, Jeffrey S , Shackelton, Lisa M , Rimola, Jordi , Ma, C , Jairath, V , Jairath, V , Jairath, Vipul , Zou, Guangyong , Gee, Michael Stanley , Dillman, Jonathan R , Fletcher, Joel G. , Griffiths, Anne Marie , Greer, Mary‐Louise C.

Inflammatory Bowel Diseases | July 31, 2023 | Volume: 30 | Issue: 3 | Pages: 357-369

10.1093/ibd/izad134 Get It

Abstract Background Perianal fistulas and abscesses occur commonly as complications of pediatric Crohn’s disease (CD). A validated imaging assessment tool for quantification of perianal disease severity and activity is needed to evaluate treatment response. We aimed to identify magnetic resonance imaging (MRI)-based measures of perianal fistulizing disease activity and study design features appropriate for pediatric patients. Methods Seventy-nine statements relevant to MRI-based assessment of pediatric perianal fistulizing CD activity and clinical trial design were generated from literature review and expert opinion. Statement appropriateness was rated by a panel (N = 15) of gastroenterologists, radiologists, and surgeons using modified RAND/University of California Los Angeles appropriateness methodology. Results The modified Van Assche Index (mVAI) and the Magnetic Resonance Novel Index for Fistula Imaging in CD (MAGNIFI-CD) were considered appropriate instruments for use in pediatric perianal fistulizing disease clinical trials. Although there was concern regarding the use of intravascular contrast material in pediatric patients, its use in clinical trials was considered appropriate. A clinically evident fistula tract and radiologic disease defined as at least 1 fistula or abscess on pelvic MRI were considered appropriate trial inclusion criteria. A coprimary clinical and radiologic end point and inclusion of a patient-reported outcome were also considered appropriate. Conclusion Outcomes of treatment of perianal fistulizing disease in children must include MRI. Existing multi-item measures, specifically the mVAI and MAGNIFI-CD, can be adapted and used for children. Further research to assess the operating properties of the indices when used in a pediatric patient population is ongoing.
P311 Reliability of computed tomography enterography for evaluation of stricturing Crohn’s disease: Development of a Crohn’s disease stricture index
Rieder, F , Baker, Mark E. , Wang, Z, Guizetti, L, Patel, Mona , Niu, Jiafei , Shackelton, L, Ottichilo, Ronald, Santillan, Cynthia , Capozzi, N, Taylor, Stuart A. , Zhou, Guo‐Ping , Bruining, David H. , Feagan, B G, Ma, Christopher , Hanžel, Jurij , Fletcher, Joel G. , Patel, M, Capozzi, Nunzia , Jairath, Vipul , Rimola, Jordi

Journal of Crohn's and Colitis | January 30, 2023 | Volume: 17 | Issue: Supplement_1 | Pages: i453-i453

10.1093/ecco-jcc/jjac190.0441 Get It

Abstract Background Computed tomography enterography (CTE) is frequently used to assess stricturing Crohn’s disease (CD). However, the reliability of CTE items used for assessment has not been established and there is no validated radiologic stricture severity index. Methods We conducted a retrospective study of 43 patients with symptomatic, terminal ileal stricturing CD. Four radiologists assessed a comprehensive list of pre-defined radiologic items potentially associated with stricture severity in 48 CTE scans in two separate rounds in random order. Reliability was quantified using the intraclass correlation coefficient (ICC). Items with at least moderate (ICC≥0.41) inter-rater reliability that were correlated with a visual analogue scale of overall stricture severity were candidate items for the development of a CTE stricture index. Results Inter-rater reliability was almost perfect for assessment of luminal diameter of pre-stenotic dilation (ICC 0.817 [95% confidence interval 0.703, 0.878]), substantial for stricture length (ICC 0.628 [0.419, 0.797]), and moderate for stricture wall thickness (0.482 [0.330, 0.601]). Intra-rater reliability was almost perfect (ICC ≥ 0.850) for all three items. A stricture severity index was derived and was well calibrated (optimism-adjusted calibration slope = 1.009), with scores calculated as the sum of stricture length (cm) + luminal diameter of pre-stenotic dilation (mm) + 5 x stricture wall thickness (mm). Conclusion Stricture length, prestenotic dilation, and stricture wall thickness can be reliably assessed, and are component items for a novel CTE stricture index (CTE-SI) of stricture severity for CD-related terminal ileal strictures. Additional external index validation for clinical and research contexts is required.
P270 A global consensus on the definitions, diagnosis and management of fibrostenosing small bowel Crohn’s disease
Baker, Mark E. , Bemelmann, W, Bruining, David H. , D’Haens, Geert , D’Hoore, André , Dignass, A, Feagan, B G, Feakins, Roger , Fleshner, Phillip , Gordon, I, Ha, Christina , Gaylyn, H, Lyu, R., Panes, J, Mao, R , Sandborn, W., Silverberg, Mark S. , Rieder, F , Bettenworth, Dominik , Dotan, Iris , Fletcher, Joel G. , Jairath, Vipul , Lu, Cathy , Ng, S C, Panés, Julián , Rogler, Gerhard , Rimola, Jordi , Siegmund, Britta , Taylor, Stuart A. , Verstockt, Bram

Journal of Crohn's and Colitis | January 30, 2023 | Volume: 17 | Issue: Supplement_1 | Pages: i418-i420

10.1093/ecco-jcc/jjac190.0400 Get It

Abstract Background Small bowel fibrostenotic strictures are common in patients with Crohn’s disease (CD). No global consensus recommendations on definitions, diagnosis and clinical management are available. Methods Several systematic reviews followed by a RAND/University of California Los Angeles appropriateness study on the definitions, diagnosis and clinical management of fibrostenosing CD in clinical practice were performed. A panel of 28 global experts and a patient representative were convened. They assessed a total of 152 candidate items. The items were subsequently evaluated for appropriateness. Results No accurate predictive biomarkers are available for naïve or anastomotic fibrostenosing strictures. Accurate diagnosis of fibrostenosing CD requires cross-sectional imaging which should evaluate bowel wall thickness, luminal narrowing and prestenotic dilatation. A potential inflammatory component should be assessed. Abdominal cross-sectional imaging was considered necessary prior to any treatment decision. The panel proposed an approach to medical, endoscopic, and surgical therapies (Figure 1 and Table 1). Technical characteristics for endoscopic balloon dilation and follow up strategies after successful dilation therapy were identified. Appropriateness, types and performance of different surgical approaches in various settings were evaluated. Conclusion This global consensus provides clinical guidance for the diagnostic and therapeutic management of patients with fibrostenotic CD.
State of the Art MR Enterography Technique
Chatterji, Manjil, Fidler, Jeff L. , Taylor, Stuart A. , Anupindi, Sudha A. , Yeh, Benjamin M. , Guglielmo, Flavius F. , Guglielmo, Flavius F , Fidler, Jeff L.

Topics in Magnetic Resonance Imaging | February 6, 2021 | Volume: 30 | Issue: 1 | Pages: 3-11

10.1097/rmr.0000000000000263 Get It

Abstract Magnetic resonance enterography (MRE) is a well-established imaging technique that is commonly used for evaluating a variety of bowel diseases, most commonly inflammatory bowel disease which is increasing in prevalence. Inflammatory bowel disease is composed of 2 related, but distinct disease entities: Crohn disease (CD) and ulcerative colitis. In ulcerative colitis, inflammation is generally limited to the mucosa and invariably involves the rectum, and often the more proximal colon. CD is typified by transmural inflammation with skip lesions occurring anywhere from the mouth to anus, but characteristically involves the terminal ileum. The transmural involvement of CD may lead to debilitating ulceration and, ultimately, development of sinus tracts, which can be associated with abscesses and fistulae as extraenteric manifestations of the disease. Because much of the small bowel and extraenteric disease cannot be adequately assessed with conventional endoscopy, imaging plays a crucial role in initial diagnosis and follow-up. MRE does not use ionizing radiation which is important for these patients, many of which present earlier in life and may require multiple imaging examinations. In this article, we review the clinical indications, patient preparation, and optimal technique for MRE. We also discuss the role and proper selection of intravenous gadolinium-based contrast material, oral contrast material, and antiperistaltic agents, including pediatric considerations. Finally, we review the recommended and optional pulse sequence selection, including discussion of a “time-efficient” protocol, reviewing their utility, advantages, and limitations. Our hope is to aid the radiologist seeking to develop a robust MRE imaging program for the evaluation of bowel disease.