Characterization of single‐ and multi‐energy CT performance of an oral dark borosilicate contrast media using a clinical photon‐counting‐detector CT platform
Ren, Liqiang , Sun, Yuxin , Yeh, Benjamin M. , Marsh, Jeffrey F., Winfree, Timothy, Burke, Kristin A., Mileto, Achille , Winfree, Timothy N, Rajendran, Kishore , McCollough, Cynthia H. , Fletcher, Joel G. , Leng, Shuai

Medical Physics | September 5, 2023 | Volume: 50 | Issue: 11 | Pages: 6779-6788

10.1002/mp.16713 Get It

AbstractBackgroundThe feasibility of oral dark contrast media is under exploration in abdominal computed tomography (CT) applications. One of the experimental contrast media in this class is dark borosilicate contrast media (DBCM), which has a CT attenuation lower than that of intra‐abdominal fat.PurposeTo evaluate the performances of DBCM using single‐ and multi‐energy CT imaging on a clinical photon‐counting‐detector CT (PCD‐CT).MethodsFive vials, three with iodinated contrast agent (5, 10, and 20 mg/mL; Omnipaque 350) and two with DBCM (6% and 12%; Nextrast, Inc.), and one solid‐water rod (neutral contrast agent) were inserted into two multi‐energy CT phantoms, and scanned on a clinical PCD‐CT system (NAEOTOM Alpha) at 90, 120, 140, Sn100, and Sn140 kV (Sn: tin filter) in multi‐energy mode. CARE keV IQ level was 180 (CTDIvol: 3.0 and 12.0 mGy for the small and large phantoms, respectively). Low‐energy threshold images were reconstructed with a quantitative kernel (Qr40, iterative reconstruction strength 2) and slice thickness/increment of 2.0/2.0 mm. Virtual monoenergetic images (VMIs) were reconstructed from 40 to 140 keV at 10 keV increments. On all images, average CT numbers for each vial/rod were measured using circular region‐of‐interests and averaged over eight slices. The contrast‐to‐noise ratio (CNR) of iodine (5 mg/mL) against DBCM was calculated and plotted against tube potential and VMI energy level, and compared to the CNR of iodine against water. Similar analyses were performed on iodine maps and VNC images derived from the multi‐energy scan at 120 kV.ResultsWith increasing kV or VMI keV, the negative HU of DBCM decreased only slightly, whereas the positive HU of iodine decreased across all contrast concentrations and phantom sizes. CT numbers for DBCM decreased from −178.5 ± 9.6 to −194.4 ± 6.3 HU (small phantom) and from −181.7 ± 15.7 to −192.1 ± 11.9 HU (large phantom) for DBCM‐12% from 90 to Sn140 kV; on VMIs, the CT numbers for DBCM decreased minimally from −147.1 ± 15.7 to −185.1 ± 9.2 HU (small phantom) and −158.8 ± 28.6 to −188.9 ± 14.7 HU (large phantom) from 40 to 70 keV, but remained stable from 80 to 140 keV. The highest iodine CNR against DBCM in low‐energy threshold images was seen at 90 or Sn140 kV for the small phantom, whereas all CNR values from low‐energy threshold images for the large phantom were comparable. The CNR values of iodine against DBCM computed on VMIs were highest at 40 or 70 keV depending on iodine and DBCM concentrations. The CNR values of iodine against DBCM were consistently higher than iodine to water (up to 460% higher dependent on energy level). Further, the CNR of iodine compared to DBCM is less affected by VMI energy level than the identical comparison between iodine and water: CNR values at 140 keV were reduced by 46.6% (small phantom) or 42.6% (large phantom) compared to 40 keV; CNR values for iodine compared to water were reduced by 86.3% and 83.8% for similar phantom sizes, respectively. Compared to 70 keV VMI, the iodine CNR against DBCM was 13%–79% lower on iodine maps and VNC.ConclusionsWhen evaluated at different tube potentials and VMI energy levels using a clinical PCD‐CT system, DBCM showed consistently higher CNR compared to iodine versus water (a neutral contrast).
State of the Art MR Enterography Technique
Chatterji, Manjil, Fidler, Jeff L. , Taylor, Stuart A. , Anupindi, Sudha A. , Yeh, Benjamin M. , Guglielmo, Flavius F. , Guglielmo, Flavius F , Fidler, Jeff L.

Topics in Magnetic Resonance Imaging | February 6, 2021 | Volume: 30 | Issue: 1 | Pages: 3-11

10.1097/rmr.0000000000000263 Get It

Abstract Magnetic resonance enterography (MRE) is a well-established imaging technique that is commonly used for evaluating a variety of bowel diseases, most commonly inflammatory bowel disease which is increasing in prevalence. Inflammatory bowel disease is composed of 2 related, but distinct disease entities: Crohn disease (CD) and ulcerative colitis. In ulcerative colitis, inflammation is generally limited to the mucosa and invariably involves the rectum, and often the more proximal colon. CD is typified by transmural inflammation with skip lesions occurring anywhere from the mouth to anus, but characteristically involves the terminal ileum. The transmural involvement of CD may lead to debilitating ulceration and, ultimately, development of sinus tracts, which can be associated with abscesses and fistulae as extraenteric manifestations of the disease. Because much of the small bowel and extraenteric disease cannot be adequately assessed with conventional endoscopy, imaging plays a crucial role in initial diagnosis and follow-up. MRE does not use ionizing radiation which is important for these patients, many of which present earlier in life and may require multiple imaging examinations. In this article, we review the clinical indications, patient preparation, and optimal technique for MRE. We also discuss the role and proper selection of intravenous gadolinium-based contrast material, oral contrast material, and antiperistaltic agents, including pediatric considerations. Finally, we review the recommended and optional pulse sequence selection, including discussion of a “time-efficient” protocol, reviewing their utility, advantages, and limitations. Our hope is to aid the radiologist seeking to develop a robust MRE imaging program for the evaluation of bowel disease.
Clinical Implementation of Dual-Energy CT for Gastrointestinal Imaging
Mileto, Achille , Ananthakrishnan, Lakshmi , Morgan, Desiree E., Yeh, Benjamin M. , Marin, Daniele , Kambadakone, Avinash , Morgan, Desiree E.

American Journal of Roentgenology | December 30, 2020 | Volume: 217 | Issue: 3 | Pages: 651-663

10.2214/ajr.20.25093 Get It

Luminal Imaging in the 21st Century
Yeh, Benjamin M. , Fidler, Jeff L. , Pickhardt, Perry J. , Carucci, Laura R. , Fidler, Jeff L.

American Journal of Roentgenology | July 1, 2011 | Volume: 197 | Issue: 1 | Pages: 28-29

10.2214/ajr.11.6756 Get It

Dual-Energy and Low-kVp CT in the Abdomen
Yeh, Benjamin M. , Wang, Zhen J. , Teh, Hui Seong , Hartman, Robert P. , Prevrhal, Sven, Shepherd, John

American Journal of Roentgenology | June 19, 2009 | Volume: 193 | Issue: 1 | Pages: 47-54

10.2214/ajr.09.2592 Get It