Developing a Carotid Pseudoaneurysm Model in Swine
Background: Traumatic carotid artery pseudoaneurysms (PSAs) represent a vascular anomaly with potential for serious complications, including stroke. Traditional treatments involve endovascular stenting, which may not be ideally suited to otherwise healthy vessels that have the potential to remodel. Given the limitations of smaller animal models in replicating human vasculature and the need for improved treatment modalities, this study introduces a novel swine model for the creation and evaluation of carotid PSAs. Methods: The PSAs were created from bovine dura and anastomosed in an end-to-side fashion to bilateral carotid arteries. The PSAs were radiologically followed up post-operatively and were harvested at 3 and 10 days for histological analysis. Results: Pseudoaneurysms were successfully created in both animals without intra-operative or immediate post-operative complications. Radiological analysis showed well-perfused PSAs with intra-aneurysmal turbulence, hemodynamically mimicking human carotid artery PSAs. There was no evidence of thrombus or arterial stenosis. Histological examinations revealed thrombus maturation and tight anastomosis of the PSA sac with the native artery. Conclusions: This PSA swine model offers a replicable, cost-effective, and easily implemented tool with the potential to advance carotid PSA management and educational efforts in vascular surgery. Clinical Impact The model presented in this methodology paper allows for a standardized PSA animal model allowing for the standardization of a clinical entity which is frequently heterogenenous in morphology. This can allow for the development of new therapies or provide a ground truth for computer modelling for further in silico study.
Magnetic and Biocompatible Polyurethane Nanofiber Biomaterial for Tissue Engineering
Recruitment of endothelial cells to cardiovascular device surfaces could solve issues of thrombosis, neointimal hyperplasia, and restenosis. Since current targeting strategies are often nonspecific, new technologies to allow for site-specific cell localization and capture in vivo are needed. The development of cytocompatible superparamagnetic iron oxide nanoparticles has allowed for the use of magnetism for cell targeting. In this study, a magnetic polyurethane (PU)-2205 stainless steel (2205-SS) nanofibrous composite biomaterial was developed through analysis of composite sheets and application to stent-grafts. The PU nanofibers provide strength and elasticity while the 2205-SS microparticles provide ferromagnetic properties. Sheets were electrospun at mass ratios of 0–4:1 (2205-SS:PU) and stent-grafts with magnetic or nonmagnetic stents were coated at the optimal ratio of 2:1. These composite materials were characterized by microscopy, mechanical testing, a sessile drop test, magnetic field measurement, magnetic cell capture assays, and cytocompatibility after 14 days of culturing with endothelial cells. Results of this study show that an optimal ratio of 2:1 2205-SS:PU results in a hydrophobic material that balanced mechanical and magnetic properties and was cytocompatible up to 14 days. Significant cell capture required a thicker material of 0.5 mm thickness. Stent-grafts fabricated from a magnetic coating and a magnetic stent demonstrated uniform cell capture throughout the device surface. This novel biomaterial exhibits a combination of mechanical and magnetic properties that enables magnetic capture of cells and other therapeutic agents for vascular and other tissue engineering applications.
Benchtop proof of concept and comparison of iron- and magnesium-based bioresorbable flow diverters
OBJECTIVE Bioresorbable flow diverters (BRFDs) could significantly improve the performance of next-generation flow diverter technology. In the current work, magnesium and iron alloy BRFDs were prototyped and compared in terms of porosity/pore density, radial strength, flow diversion functionality, and resorption kinetics to offer insights into selecting the best available bioresorbable metal candidate for the BRFD application. METHODS BRFDs were constructed with braided wires made from alloys of magnesium (MgBRFD) or iron (FeBRFD). Pore density and crush resistance force were measured using established methods. BRFDs were deployed in silicone aneurysm models attached to flow loops to investigate flow diversion functionality and resorption kinetics in a simulated physiological environment. RESULTS The FeBRFD exhibited higher pore density (9.9 vs 4.3 pores/mm2) and crush resistance force (0.69 ± 0.05 vs 0.53 ± 0.05 N/cm, p = 0.0765, n = 3 per group) than the MgBRFD, although both crush resistances were within the range previously reported for FDA-approved flow diverters. The FeBRFD demonstrated greater flow diversion functionality than the MgBRFD, with significantly higher values of established flow diversion metrics (mean transit time 159.6 ± 11.9 vs 110.9 ± 1.6, p = 0.015; inverse washout slope 192.5 ± 9.0 vs 116.5 ± 1.5, p = 0.001; n = 3 per group; both metrics expressed as a percentage of the control condition). Last, the FeBRFD was able to maintain its braided structure for > 12 weeks, whereas the MgBRFD was almost completely resorbed after 5 weeks. CONCLUSIONS The results of this study demonstrated the ability to manufacture BRFDs with magnesium and iron alloys. The data suggest that the iron alloy is the superior material candidate for the BRFD application due to its higher mechanical strength and lower resorption rate relative to the magnesium alloy.
Morphological and Hemodynamic Changes during Cerebral Aneurysm Growth
Computational fluid dynamics (CFD) has grown as a tool to help understand the hemodynamic properties related to the rupture of cerebral aneurysms. Few of these studies deal specifically with aneurysm growth and most only use a single time instance within the aneurysm growth history. The present retrospective study investigated four patient-specific aneurysms, once at initial diagnosis and then at follow-up, to analyze hemodynamic and morphological changes. Aneurysm geometries were segmented via the medical image processing software Mimics. The geometries were meshed and a computational fluid dynamics (CFD) analysis was performed using ANSYS. Results showed that major geometry bulk growth occurred in areas of low wall shear stress (WSS). Wall shape remodeling near neck impingement regions occurred in areas with large gradients of WSS and oscillatory shear index. This study found that growth occurred in areas where low WSS was accompanied by high velocity gradients between the aneurysm wall and large swirling flow structures. A new finding was that all cases showed an increase in kinetic energy from the first time point to the second, and this change in kinetic energy seems correlated to the change in aneurysm volume.
Computational Fluid Dynamics of a Fatal Ruptured Anterior Communicating Artery Aneurysm
AbstractComputational fluid dynamics (CFD) has been studied as a tool for the stratification of aneurysm rupture risk. We performed CFD analysis in a patient operated on for a ruptured anterior communicating artery aneurysm. The point of rupture was identified during surgery. The aneurysm and blood vessels were segmented from computed tomography angiography to prepare a model for simulations. We found that the streamlines showed a concentrated inflow jet directed straight at the rupture point, and high wall shear stress was found at the point of rupture in the aneurysm sac. Thus specific local hemodynamics may be indicative of the aneurysm rupture site.