Back to Authors

Choe, Joshua A.

https://orcid.org/0000-0003-4757-8849

Mayo Clinic

Mayo Clinic

Citations 3

Magnetic and Biocompatible Polyurethane Nanofiber Biomaterial for Tissue Engineering
Dragomir‐Daescu, Dan , Sandhu, Gurpreet S. , Tefft, Brandon J. , Choe, Joshua A. , Uthamaraj, Susheil , Dragomir-Daescu, Dan, Tefft, Brandon J

Tissue Engineering Part A | May 2, 2023 | Volume: 29 | Issue: 15-16 | Pages: 413-423

10.1089/ten.tea.2022.0224 Get It

Recruitment of endothelial cells to cardiovascular device surfaces could solve issues of thrombosis, neointimal hyperplasia, and restenosis. Since current targeting strategies are often nonspecific, new technologies to allow for site-specific cell localization and capture in vivo are needed. The development of cytocompatible superparamagnetic iron oxide nanoparticles has allowed for the use of magnetism for cell targeting. In this study, a magnetic polyurethane (PU)-2205 stainless steel (2205-SS) nanofibrous composite biomaterial was developed through analysis of composite sheets and application to stent-grafts. The PU nanofibers provide strength and elasticity while the 2205-SS microparticles provide ferromagnetic properties. Sheets were electrospun at mass ratios of 0–4:1 (2205-SS:PU) and stent-grafts with magnetic or nonmagnetic stents were coated at the optimal ratio of 2:1. These composite materials were characterized by microscopy, mechanical testing, a sessile drop test, magnetic field measurement, magnetic cell capture assays, and cytocompatibility after 14 days of culturing with endothelial cells. Results of this study show that an optimal ratio of 2:1 2205-SS:PU results in a hydrophobic material that balanced mechanical and magnetic properties and was cytocompatible up to 14 days. Significant cell capture required a thicker material of 0.5 mm thickness. Stent-grafts fabricated from a magnetic coating and a magnetic stent demonstrated uniform cell capture throughout the device surface. This novel biomaterial exhibits a combination of mechanical and magnetic properties that enables magnetic capture of cells and other therapeutic agents for vascular and other tissue engineering applications.
In Silico Performance of a Recellularized Tissue-Engineered Transcatheter Aortic Valve
Noble, Christopher , Choe, Joshua A. , Uthamaraj, Susheil , DeHerrera, Milton, Young, Melissa , Choe, Joshua, Lerman, Amir

Journal of Biomechanical Engineering | March 15, 2019 | Volume: 141 | Issue: 6 | Pages: 061004-061004-12

10.1115/1.4043209 Get It

Commercially available heart valves have many limitations, such as a lack of remodeling, risk of calcification, and thromboembolic problems. Many state-of-the-art tissue-engineered heart valves (TEHV) rely on recellularization to allow remodeling and transition to mechanical behavior of native tissues. Current in vitro testing is insufficient in characterizing a soon-to-be living valve due to this change in mechanical response; thus, it is imperative to understand the performance of an in situ valve. However, due to the complex in vivo environment, this is difficult to accomplish. Finite element (FE) analysis has become a standard tool for modeling mechanical behavior of heart valves; yet, research to date has mostly focused on commercial valves. The purpose of this study has been to evaluate the mechanical behavior of a TEHV material before and after 6 months of implantation in a rat subdermis model. This model allows the recellularization and remodeling potential of the material to be assessed via a simple and inexpensive means prior to more complex ovine orthotropic studies. Biaxial testing was utilized to evaluate the mechanical properties, and subsequently, constitutive model parameters were fit to the data to allow mechanical performance to be evaluated via FE analysis of a full cardiac cycle. Maximum principal stresses and strains from the leaflets and commissures were then analyzed. The results of this study demonstrate that the explanted tissues had reduced mechanical strength compared to the implants but were similar to the native tissues. For the FE models, this trend was continued with similar mechanical behavior in explant and native tissue groups and less compliant behavior in implant tissues. Histology demonstrated recellularization and remodeling although remodeled collagen had no clear directionality. In conclusion, we observed successful recellularization and remodeling of the tissue giving confidence to our TEHV material; however, the mechanical response indicates the additional remodeling would likely occur in the aortic/pulmonary position.
Biomaterial characterization of off-the-shelf decellularized porcine pericardial tissue for use in prosthetic valvular applications
Choe, Joshua A. , Jana, Soumen , Tefft, Brandon J. , Hennessy, Ryan S., Go, Jason L. , Morse, David , Go, Jason, Young, Melissa D , Morse, David , Lerman, Amir

Journal of Tissue Engineering and Regenerative Medicine | May 11, 2018 | Volume: 12 | Issue: 7 | Pages: 1608-1620

10.1002/term.2686 Get It