Back to Authors

Wood, Benjamin

Mayo Clinic

Mayo Clinic

Citations 2

Spectro-temporal signal analysis of twinkling artifacts from PMMA markers
Masud, Abdullah Al , Wood, Benjamin, Lee, Christine, Wood, Benjamin, Urban, Matthew W.

The Journal of the Acoustical Society of America | May 12, 2026 | Volume: 158 | Issue: 4_Supplement | Pages: A39-A39

10.1121/10.0040054 Get It

Color Doppler twinkling improves visibility and ultrasound-guided localization of biopsy markers made of polymethyl methacrylate (PMMA). This study examines the time- and frequency-domain features of twinkling. We performed beamforming on the raw radiofrequency (RF) data collected using a L7-4 transducer, followed by in-phase/quadrature (IQ) demodulation and wall filtering. Frequency content variations were evaluated both within individual Doppler ensembles (pulse-to-pulse) and across multiple frames. Normalized FFT magnitude spectra were computed for both twinkling and non-twinkling (metal) cases using beamformed RF and IQ data. The median of the normalized FFT magnitude (3–10 MHz) was consistently higher for the twinkling case compared to the metal case across RF (–13.75 dB vs –17.29 dB) and the IQ real component (–12.72 dB vs –16.15 dB), indicating broader and more energetic spectral content in twinkling. The frequency spread above the –20 dB threshold was approximately 2.5 times wider (5.38 MHz vs 1.95 MHz) in the twinkling case compared to the metal case. In time domain, the RMS of the standard deviation for the twinkling signal was approximately 28 times higher than that of the metal case across both RF and IQ data. These findings indicate that the ultrasound data from twinkling exhibits a more distributed frequency profile, consistent with observed aperiodic nature.
Pressure chamber and micro-CT analysis of twinkling materials to evaluate features important to color Doppler twinkling
Wood, Benjamin, Vercnocke, Andrew, Marsh, Jeff, Lee, Christine, Vercnocke, Andrew J. , Marsh, Jeffrey F., Urban, Matthew W.

The Journal of the Acoustical Society of America | May 12, 2026 | Volume: 158 | Issue: 4_Supplement | Pages: A426-A426

10.1121/10.0041383 Get It

Color Doppler twinkling is associated with rough-surfaced objects like kidney stones, some clinical breast biopsy markers, and polymethyl methacrylate (PMMA) bone cement. Microbubbles are theorized as the predominant source of twinkling, supported by decreased twinkling under increased pressure. PMMA, metallic breast markers, a low-twinkling PMMA sample, and a non-twinkling metal rod were scanned in a pressure chamber up to 1000 psi using a General Electric Logiq E9 system and C1-6 probe (1.7–3.6 MHz Doppler transmit frequency). Clinical markers maintained distinct twinkling up to 250 psi. PMMA often twinkled at higher pressures, sometimes up to 1000 psi. The controls showed no twinkling. To understand physical structure associations with twinkling, the samples were scanned in a micro-CT system with a pixel resolution of 2 μm. Analysis of PMMA and Cork internal voids showed no correlation with twinkling. However, a correlation between Sa (average difference between the mean surface profile and actual surface profile) values and twinkling was found. This indicates that internal structure is not important for twinkling, and certain surface roughness is critical, possibly providing sites for surface microbubbles to oscillate from incident ultrasound waves.