Back to Authors

Allmendinger, Thomas

https://orcid.org/0000-0002-3133-4017

Mayo Clinic

Siemens Healthineers (Germany)

Citations 3

Simultaneous ultra-high resolution multi-energy cardiac imaging in a dual-source photon counting detector CT system
Shanblatt, Elisabeth R. , Swicklik, Joseph R., Allmendinger, Thomas , Schmidt, Bernhard , Flohr, Thomas , McCollough, Cynthia H. , Leng, Shuai , McCollough, Cynthia H , Leng, Shuai , Rajendran, Kishore

British Journal of Radiology | March 30, 2025 | Volume: 98 | Issue: 1175 | Pages: 1873-1879

10.1093/bjr/tqaf069 Get It

Abstract Objectives To assess quantitative and qualitative image characteristics in phantoms and patients using a simultaneous ultra-high resolution (UHR) and multi-energy (ME) dual-source cardiac scan mode in a photon counting detector (PCD) CT scanner. Methods UHR-ME cardiac scans were performed to determine the spatial resolution and multi-energy performance. UHR reconstructions were completed to measure transverse and axial spatial resolution in terms of modulation transfer function (MTF) and slice sensitivity profile (SSP). Virtual monoenergetic images (VMIs), virtual non-contrast (VNC) images, and iodine concentration images were created using moderately sharp reconstruction kernels to assess ME performance. With IRB approval, coronary CT angiograms were acquired in 19 patients using the UHR-ME mode, from which iodine contrast-to-noise ratio (CNR) was measured. Various ME post-processing tasks were performed to show the utility of the spectral capabilities. Results VMIs showed a mean CT number error of 6.0%, while iodine accuracy was 0.71 mg/cc (root-mean-square-error). Spatial resolution matched well with a standard UHR mode. Patient images showed a trend of higher CNR at lower keV, while higher keV images showed decreased calcium blooming. ME techniques to separate iodine and calcium were used successfully. Conclusions The combination of UHR-ME cardiac mode retains UHR image quality while providing flexibility for ME post-processing. Advances in knowledge Cardiac UHR-ME PCD-CT scanning offers simultaneous UHR and ME imaging without loss of spatial or temporal resolution or quantitative accuracy.
Energy‐integrating‐detector multi‐energy CT: Implementation and a phantom study
Ren, Liqiang , Allmendinger, Thomas , Halaweish, Ahmed F., Schmidt, Bernhard , Flohr, Thomas , Yu, Lifeng , McCollough, Cynthia H. , Yu, Lifeng

Medical Physics | May 14, 2021 | Volume: 48 | Issue: 9 | Pages: 4857-4871

10.1002/mp.14943 Get It

PurposeMulti‐energy computed tomography (MECT) has a great potential to enable many novel clinical applications such as simultaneous multi‐contrast imaging. The purpose of this study was to implement triple‐beam MECT on a traditional energy‐integrating‐detector (EID) CT platform (EID‐MECT).MethodsThis was accomplished by mounting a z‐axis split‐filter (0.05 mm Au, 0.6 mm Sn) on Tube A of a dual‐source EID CT scanner. With the two split x‐ray beams from Tube A and the third beam from Tube B, three beams with different x‐ray spectra can be simultaneously acquired. With Tube B operated at 70 or 80 kV and Tube A at 120 or 140 kV, four different triple‐beam configurations were calibrated for MECT measurements: 70/Au120/Sn120, 80/Au120/Sn120, 70/Au140/Sn140, and 80/Au140/Sn140 kV. Iodine (I), gadolinium (Gd), bismuth (Bi) samples, and their mixtures were prepared for 2 three‐material‐decomposition tasks and 1 four‐material‐decomposition task. For each task, samples were placed in a water phantom and scanned using each of the four triple‐beam configurations. For comparison, the same phantom was also scanned using three other dual‐energy CT (DECT) or MECT technologies: twin‐beam DECT (TB‐DECT), dual‐source DECT (DS‐DECT), and photon‐counting‐detector CT (PCD‐CT), all with optimal x‐ray spectrum settings and at equal volume CT dose index (CTDIvol). The phantom for four‐material decomposition (I/Gd/Bi/Water imaging) was scanned using the PCD‐CT only (140 kV with 25, 50, 75, and 90 keV). Image‐based material decomposition was performed to acquire material‐specific images, on which the mean basis material concentrations and noise levels were measured and compared across all triple‐beam configurations in EID‐MECT and various DECT/MECT systems.ResultsThe optimal triple‐beam configuration was task‐dependent with 70/Au120/Sn120, 70/Au140/Sn140, and 70/Au120/Sn120 kV for I/Gd/Water, I/Bi/Water, and I/Gd/Bi/Water material decomposition tasks, respectively. At equal radiation dose level, EID‐MECT provided comparable or better quantification accuracy in material‐specific images for all three material decomposition tasks, compared to EID‐based DECT and PCD‐CT systems. In terms of noise level comparison, EID‐MECT‐derived material‐specific images showed lower noise levels than TB‐DECT and DS‐DECT, but slightly higher than that from PCD‐CT in I/Gd/Water imaging. For I/Bi/Water imaging, EID‐MECT showed a comparable noise level to DS‐DECT, and a much lower noise level than TB‐DECT and PCD‐CT in all material‐specific images. For the four‐material decomposition task involving I/Gd/Bi/Water, the bismuth‐specific image derived from EID‐MECT was slightly noisier, but both iodine‐ and gadolinium‐specific images showed much lower noise levels in comparison to PCD‐CT.ConclusionsFor the first time, an EID‐based MECT system that can simultaneously acquire three x‐ray spectra measurements was implemented on a clinical scanner, which demonstrated comparable or better imaging performance than existing DECT and MECT systems.
Electronic Noise in CT Detectors: Impact on Image Noise and Artifacts
Duan, Xinhui , Wang, Jia , Schmidt, Bernhard , Allmendinger, Thomas , Grant, Katharine L., Flohr, Thomas , Leng, Shuai , McCollough, Cynthia H.

American Journal of Roentgenology | September 24, 2013 | Volume: 201 | Issue: 4 | Pages: W626-W632

10.2214/ajr.12.10234 Get It