Back to Authors

Wang, Jia

https://orcid.org/0000-0003-3295-5963

Mayo Clinic

Stanford University

Citations 6

Performance evaluation of computed tomography systems: Summary of AAPM Task Group 233
Bakalyar, Donovan, Boedeker, Kirsten , Fan, Jiahua , Myers, Kyle J. , Popescu, Lucreţiu M. , Giraldo, Juan Carlos Ramírez, Ranallo, Frank N. , Solomon, Justin , Vaishnav, J. Y., Wang, Jia , Samei, Ehsan , Brady, Samuel L. , Leng, Shuai , Vaishnav, Jay

Medical Physics | August 13, 2019 | Volume: 46 | Issue: 11 | Pages: No page available

10.1002/mp.13763 Get It

Background The rapid development and complexity of new x‐ray computed tomography (CT) technologies and the need for evidence‐based optimization of image quality with respect to radiation and contrast media dose call for an updated approach towards CT performance evaluation. Aims This report offers updated testing guidelines for testing CT systems with an enhanced focus on the operational performance including iterative reconstructions and automatic exposure control (AEC) techniques. Materials and Methods The report was developed based on a comprehensive review of best methods and practices in the scientific literature. The detailed methods include the assessment of 1) CT noise (magnitude, texture, nonuniformity, inhomogeneity), 2) resolution (task transfer function under varying conditions and its scalar reflections), 3) task‐based performance (detectability, estimability), and 4) AEC performance (spatial, noise, and mA concordance of attenuation and exposure modulation). The methods include varying reconstruction and tube current modulation conditions, standardized testing protocols, and standardized quantities and metrology to facilitate tracking, benchmarking, and quantitative comparisons. Results The methods, implemented in cited publications, are robust to provide a representative reflection of CT system performance as used operationally in a clinical facility. The methods include recommendations for phantoms and phantom image analysis. Discussion In line with the current professional trajectory of the field toward quantitation and operational engagement, the stated methods offer quantitation that is more predictive of clinical performance than specification‐based approaches. They can pave the way to approach performance testing of new CT systems not only in terms of acceptance testing (i.e., verifying a device meets predefined specifications), but also system commissioning (i.e., determining how the system can be used most effectively in clinical practice). Conclusion We offer a set of common testing procedures that can be utilized towards the optimal clinical utilization of CT imaging devices, benchmarking across varying systems and times, and a basis to develop future performance‐based criteria for CT imaging.
Electronic Noise in CT Detectors: Impact on Image Noise and Artifacts
Duan, Xinhui , Wang, Jia , Schmidt, Bernhard , Allmendinger, Thomas , Grant, Katharine L., Flohr, Thomas , Leng, Shuai , McCollough, Cynthia H.

American Journal of Roentgenology | September 24, 2013 | Volume: 201 | Issue: 4 | Pages: W626-W632

10.2214/ajr.12.10234 Get It

Differentiation of Calcium Oxalate Monohydrate and Calcium Oxalate Dihydrate Stones Using Quantitative Morphological Information from Micro-Computerized and Clinical Computerized Tomography
Duan, Xinhui , Qu, Mingliang , Wang, Jia , Trevathan, James K. , Vrtiska, Terri J., Williams, James C. , Krambeck, Amy E. , Lieske, John C. , McCollough, Cynthia H. , Trevathan, James K

Journal of Urology | November 7, 2012 | Volume: 189 | Issue: 6 | Pages: 2350-2356

10.1016/j.juro.2012.11.004 Get It

Kidney Stone Volume Estimation from Computerized Tomography Images Using a Model Based Method of Correcting for the Point Spread Function
Duan, Xinhui , Wang, Jia , Qu, Mingliang , Krambeck, Amy E. , Leng, Shuai , Liu, Yu , McCollough, Cynthia H.

Journal of Urology | July 21, 2012 | Volume: 188 | Issue: 3 | Pages: 989-995

10.1016/j.juro.2012.04.098 Get It

Dose Reduction to Anterior Surfaces With Organ-Based Tube-Current Modulation: Evaluation of Performance in a Phantom Study
Duan, Xinhui , Wang, Jia , Christner, Jodie A., Grant, Katharine L., Leng, Shuai , McCollough, Cynthia H.

American Journal of Roentgenology | August 23, 2011 | Volume: 197 | Issue: 3 | Pages: 689-695

10.2214/ajr.10.6061 Get It

Differentiation of uric acid versus non-uric acid kidney stones in the presence of iodine using dual-energy CT
Wang, Jia , Qu, Mingliang , Leng, Shuai , McCollough, Cynthia H.

SPIE Proceedings | March 17, 2010 | Volume: 7622 | Issue: No issue available | Pages: 76223O

10.1117/12.845046 Get It