AbstractPurposeA dual‐source CT system can be operated in a high‐pitch helical mode to provide a temporal resolution of 66 ms, which reduces motion artifacts in CT pulmonary angiography (CTPA). It can also be operated in a multi‐energy (ME) mode to provide iodine maps, beneficial in the evaluation of pulmonary embolism (PE). No energy‐integrating detector (EID) CT can perform simultaneous ME and high‐pitch acquisition. This phantom study aimed to evaluate the ability of a photon‐counting‐detector (PCD) CT to perform simultaneous high‐pitch and ME imaging for CTPA.MethodsA motion phantom was used to mimic the respiratory motion. Two tubes filled with iodine with intravascular thrombus mimicked by injecting glue within the tubes were placed along with 5, 10, and 15 mg/mL iodine samples, on a motion phantom at 20 and 30 revolutions per minute. Separate high‐pitch and ME EID‐CT scans and a single high‐pitch ME PCD scan were acquired and virtual monoenergetic images and iodine maps reconstructed. Percent thrombus occlusion was measured and compared between static and moving images.ResultsWhen there was motion, EID‐CT ME suffered from significant motion artifacts. The measured iodine concentrations with PCD‐CT in high‐pitch ME were more stable when there was a motion, with a lower standard deviation than EID‐CT in ME mode. The estimated percent thrombus occlusion dropped significantly with applied motion on EID‐CT, while PCD‐CT high‐pitch ME mode showed good agreement between measurements on static or moving images.ConclusionPCD‐CT with combined ME and high‐pitch mode facilitates simultaneous accurate iodine quantification and assessment of intravascular occlusion.
Comparison of human observer impression of X-ray fluoroscopy and angiography image quality with technical changes to image quality
Background/Aim. The iliopsoas muscle [musculus (m.) iliopsoas] originates from the Greek word ps?a, which means loin and represents the only muscle in the body with anatomical preconditions to simultaneously and directly contribute to the stability and movement of the trunk, pelvis, and legs. M. iliopsoas belongs to the inner thigh muscle group and forms part of the posterior abdominal wall. This muscle is the major flexor of the hip joint, and it is functionally essential for proper posture, walking, running, and other physical activities. The aim of this study was to determine the relationship between the anatomical parameters of the pelvis and nervus (n.) femoralis, as well as the relationship between the same pelvic parameters and m. psoas major. Methods. The study was conducted at the Faculty of Medicine, University of Belgrade, on cadaveric material of the Institute of Anatomy ?Niko Miljanic?. For measurement purposes, 14 cadavers were used, seven of which were male and seven female, aged 67?79 years. The measuring instruments used in this study were a ruler and an electronic digital caliper (measuring range 0?500 mm, resolution 0.01 mm). Statistical data processing was performed in the SPSS 11.0 program using the Mann-Whitney U test. Results. The results of this study indicate a significant statistical difference in pelvic width between male and female cadavers, which was observed in the reduction of the bituberal line in females, while the parameters of the bispinal line showed no significant difference between the two genders. The decrease of the bituberal line in females was followed by an increase in the width of the proximal origin with a statistically significant decrease in the length of the proximal origin of the m. psoas major. Furthermore, the vertical distance of n. femoralis from the exit point of the muscle to the bispinal line was significantly reduced in the male cadavers. Conclusion. Based on our results, we can assume that, in most cases, due to the smaller bituberal and bispinal line or narrower pelvis, a shorter proximal attachment of the m. psoas major will occur with greater width (L2?L5 level) in the female than in the male gender, resulting in a longer vertical distance of n. femoralis. Such results indicate a close correlation between the anatomical parameters of the m. psoas major, which may affect the distance of n. femoralis exit from the muscle.