Purpose: To evaluate the performance of a new, highly flexible radiofrequency (RF) coil system for imaging patients undergoing MR simulation. Methods: Volumetric phantom and in vivo images were acquired with a commercially available and prototype RF coil set. Phantom evaluation was performed using a silicone-filled humanoid phantom of the head and shoulders. In vivo assessment was performed in five healthy and six patient subjects. Phantom data included T1-weighted volumetric imaging, while in vivo acquisitions included both T1- and T2-weighted volumetric imaging. Signal to noise ratio (SNR) and uniformity metrics were calculated in the phantom data, while SNR values were calculated in vivo. Statistical significance was tested by means of a non-parametric analysis of variance test. Results: At a threshold of p = 0.05, differences in measured SNR distributions within the entire phantom volume were statistically different in two of the three paired coil set comparisons. Differences in per slice average SNR between the two coil sets were all statistically significant, as well as differences in per slice image uniformity. For patients, SNRs within the entire imaging volume were statistically significantly different in four of the nine comparisons and seven of the nine comparisons performed on the per slice average SNR values. For healthy subjects, SNRs within the entire imaging volume were statistically significantly different in seven of the nine comparisons and eight of the nine comparisons when per slice average SNR was tested. Conclusions: Phantom and in vivo results demonstrate that image quality obtained from the novel flexible RF coil set was similar or improved over the conventional coil system. The results also demonstrate that image quality is impacted by the specific coil configurations used for imaging and should be matched appropriately to the anatomic site imaged to ensure optimal and reproducible image quality.
Recent developments in the characterization of anisotropic, biological media utilizing magnetic resonance elastography
In this paper, we present recent developments in the characterization of anisotropic, biological media utilizing displacements measured with dynamic MRE. In one approach, a waveguide constrained analysis is applied to physical structures (such as muscle), which evaluates the velocities of wave propagation along arbitrarily oriented fibers or fiber bundles in a local fashion, utilizing a spectral filter and a sliding window, spatial Fourier transform. In a second approach, the anisotropic equations of elasticity, in variational form, are inverted for a determination of the complex moduli comprising the medium. Issues concerning ill-conditioning, the effects of boundary conditions, and multiaspect excitation requirements will be addressed, as well as a discussion concerning the models which are appropriate for various physical situations. These two complementary methods of analysis will be demonstrated utilizing both phantom as well as in vivo dynamic displacement measurements.
Magnetic Resonance Elastography Assessment of Focused Ultrasound Surgery in Cancer Models: A Pilot Study
MRI guided focused ultrasound (FUS) has been shown to create thermal lesions where tissue stiffness changes significantly. To assess the correlation between tissue stiffness change and tissue ablation, a pilot animal based study was conducted to treat LNCaP tumors in vivo and Hep3B tumors immediately post mortem. MR elastography was used to analyze tissue stiffness before and after ablation. Treated tissue was excised immediately after each experiment and processed by routine histological analysis. Four prostate cancer tumors and four liver cancer tumors showed, on average, a threefold increase in stiffness due to FUS thermal treatment. Histology showed complete (100%) coagulation necrosis in these cases. These data suggest that MRE may be an effective means to assess tissue ablation.