Back to Authors

Hoffman, E. Matthew

https://orcid.org/0000-0001-7293-8290

Mayo Clinic

Mayo Clinic

Citations 21

Minimal changes in excitation-contraction coupling in spastic human muscle
Wang, Zheng , Hoffman, E. Matthew , Litchy, William J. , Rhee, Peter C. , Lieber, Richard L. , Hoffman, Ernest Matthew , Rhee, Peter C , Kaufman, Kenton R , Lieber, Richard L , Shin, Alexander Y. , Kaufman, Kenton R.

Journal of Neurophysiology | September 6, 2025 | Volume: 134 | Issue: 4 | Pages: 1069-1074

10.1152/jn.00274.2025 Get It

This study presents the first in vivo intraoperative measurement of the kinetic properties of spastic human muscle. Despite slower relaxation in spastic biceps, the force-frequency relationship was similar to that of the healthy gracilis muscle. This suggests that spasticity does not substantially alter frequency-dependent force summation, possibly due to similar fiber-type compositions and limited changes in calcium handling or myosin isoforms in human spastic muscle.
In vivo human gracilis muscle active force‐length relationship is explained by the sliding filament theory
Wang, Zheng , Persad, Lomas S. , Binder‐Markey, Benjamin I. , Hoffman, E. Matthew , Litchy, William J. , Lieber, Richard L. , Hoffman, Ernest Matthew , Lieber, Richard L , Shin, Alexander Y. , Kaufman, Kenton R.

The Journal of Physiology | May 11, 2025 | Volume: 603 | Issue: 10 | Pages: 3049-3059

10.1113/jp288322 Get It

AbstractThe sliding filament theory explains skeletal muscle fibre force change as a function of length based on the overlap of actin and myosin filaments. Although this length‐tension (LT) relationship has been well investigated in animal models, it is not known whether this microscopic sarcomere LT property can be scaled up five orders of magnitude to explain the LT behaviour of a long human muscle such as the gracilis. The goal of this study is to validate the sarcomere LT curve in humans based on human filament length combined with in vivo experimental data. Intraoperative measurements of maximal tetanic force and muscle‐tendon unit length at four different joint configurations (JC) were obtained from 19 patients undergoing free functioning muscle transfer surgery. With physiologically measured fibre length and estimated sarcomere shortening resulting from tendon compliance, we show that 79.7% variance in isometric force data is explained by a simple human sarcomere LT model. This study demonstrates that the human whole muscle LT relationship can be modelled by the sliding filament theory given patient‐specific fibre length, filament length, tendon compliance and sarcomere shortening. imageKey points Whole human gracilis muscle isometric length‐tension relationships were measured in the operating room. Grouped whole muscle raw length‐tension curves showed no obvious form. The width of each experimental length‐tension curve was highly variable across subjects and used to predict fibre length (serial sarcomere number). After whole muscle length‐tension curves were normalized to each patient's serial sarcomere number, the whole human muscle length‐tension curve was well predicted by the sliding filament theory.
The potential of preoperative dynamic electromyography in guiding targeted surgical procedures for elbow spasticity
Wang, Zheng , Lunasin, Ray M. , Hoffman, E. Matthew , Rhee, Peter C. , Hoffman, Ernest M., Kaufman, Kenton R , Lieber, Richard L. , Kaufman, Kenton R.

Journal of Hand Surgery (European Volume) | February 28, 2025 | Volume: 50 | Issue: 11 | Pages: 1534-1537

10.1177/17531934251323078 Get It

Six patients treated by hyperselective neurectomy were assessed using preoperative dynamic electromyography and intraoperative force measurements. Patients with lower preoperative biceps dynamic electromyography activation had significantly reduced force production at operation, suggesting that these findings could guide and improve procedure selection. Level of evidence: IV
McArdle sign and neck flexion-induced change in central motor conduction in multiple sclerosis
Hoffman, E. Matthew , Brown, Lucille, Jolliffe, Evan, Sechi, Elia , Harmsen, William S. , Schilaty, Nathan D. , Weinshenker, Brian G. , Weinshenker, Brian G , Schilaty, Nathan D , Sechi, Elia

Multiple Sclerosis Journal | November 6, 2024 | Volume: 30 | Issue: 14 | Pages: 1830-1834

10.1177/13524585241295868 Get It

Background: Rapidly reversible weakness with neck flexion (McArdle sign) is common in patients with multiple sclerosis (MS). The pathophysiology is unknown. Objective: To evaluate changes in central motor conduction time (CMCT) in patients with and without McArdle sign. Methods: We measured McArdle sign with a torque cell and CMCT with neck flexed and extended in patients with MS, other causes of myelopathy, and healthy controls. Results: CMCT was prolonged with neck flexion disproportionately in those with MS-associated myelopathy (MSAM) with prominent McArdle sign compared to MS patients with lesser degrees of McArdle sign, and to controls. Conclusion: McArdle sign may result from stretch-induced slowing of conduction due to demyelination.
Novel Use of Motor-Evoked Potential Monitoring During Magnetic Resonance Imaging-Guided Soft-Tissue Cryoablation: A Case Report
Forcrand, Claire de, Oishi, Tatsuya , Woodrum, David A. , Lu, Aiming , Favazza, Chris P., Hoffman, E. Matthew , Pasternak, Jeffrey J., Powell, Garret M. , Teixeira, Miguel T. , Hoffman, Ernest M., Thompson, Scott M. , Adamo, Daniel A. , Favazza, Christopher

A&A Practice | August 6, 2024 | Volume: 18 | Issue: 8 | Pages: e01832

10.1213/xaa.0000000000001832 Get It

Motor-evoked potential (MEP) monitoring is an electrophysiologic technique useful for testing peripheral motor nerve integrity during cryoablation cases with risk of nerve injury. Previously, neuromonitoring within the magnetic resonance imaging (MRI) suite for cryoablation has not been performed as magnetic needles are used which could cause magnetic field interactions with neuromonitoring leads. We present the first report of a patient who underwent MEP monitoring during MRI-guided cryoablation of a vascular malformation adjacent to the brachial plexus. We demonstrate that MEPs may be safely and accurately performed by interleaving MRI and MEPs during treatment, reducing the risk of postprocedural complications.
Extraocular muscle electromyographic recordings for intraoperative monitoring of cranial nerves III, IV, and VI: a single-center experience with intraorbital electrodes
Oishi, Tatsuya , Link, Michael J. , Celda, María Peris, Hoffman, E. Matthew , Gompel, Jamie J. Van , Daniels, David J., Morris, Jonathan M.

Journal of Neurosurgery | April 6, 2024 | Volume: 141 | Issue: 3 | Pages: 730-741

10.3171/2024.1.jns231867 Get It

OBJECTIVE The objective of this study was to describe the quantitative features of intraoperative electromyographic recordings obtained from cranial nerve III, IV, and VI neuromonitoring using 25-mm intraorbital electrodes, in the larger context of demonstrating the practicality of this technique during neurosurgical cases. METHODS A 25-mm-long shaft-insulated intraorbital needle electrode is routinely used at the authors’ institution for extraocular muscle (EOM) electromyographic monitoring of the inferior rectus, superior oblique, and/or lateral rectus muscles when their function is at risk. Cases monitored between January 1, 2021, and December 31, 2022, were reviewed for patient demographics, tumor location and pathology, EOMs monitored, pre- and postoperative examination, and complications from electrode placement. Compound muscle action potentials on triggered electromyography, as well as neurotonic discharges on free-run electromyography, were described quantitatively. RESULTS There were 141 cases in 139 patients reviewed during the 24-month time span, with 278 EOMs monitored (inferior rectus/superior oblique/lateral rectus muscles 68/68/142). Triggered electromyography yielded biphasic or triphasic compound muscle action potentials from EOMs with a mean onset latency of 1.51 msec (range 0.94–3.22 msec), mean maximal peak-to-trough amplitude of 1073.93 μV (range 76.75–7796.29 μV), and high specificity for the channel in nearly all cases. Neurotonic discharges were recorded in 30 of the 278 EOMs (with all 3 muscles represented) and associated with a greater incidence of new or worsened ophthalmoparesis (OR 4.62, 95% CI 1.3–16.4). There were 2 cases of small periorbital ecchymosis attributed to needle placement; additionally, 1 case of needle-related intraorbital hematoma occurred after the review period. CONCLUSIONS The 25-mm shaft-insulated intraorbital electrode facilitates robust and consistent electromyographic recordings of EOMs that are advantageous over existing techniques. Combined with the relative ease of needle placement and low rate of complications, the technique is practical for neuromonitoring during craniotomies.
Opioid Usage in Peripheral Neuropathy: A Population-Based Study (P6.096)
Hoffman, E. Matthew , Staff, Nathan P. , Klein, Christopher J.

Neurology | December 7, 2023 | Volume: 82 | Issue: 10_supplement | Pages: No page available

10.1212/wnl.82.10_supplement.p6.096 Get It

A population-based approach to chemotherapy-induced peripheral neuropathy reveals the disease burden of early and late effects (P5.117)
Shah, Arya , Hoffman, E. Matthew , Klein, Christopher J. , Staff, Nathan P.

Neurology | December 7, 2023 | Volume: 88 | Issue: 16_supplement | Pages: No page available

10.1212/wnl.88.16_supplement.p5.117 Get It

Population Characteristics and Progression to Disability Among Patients with Small Fiber Neuropathy (2538)
Johnson, Stephen , Hoffman, E. Matthew , Staff, Nathan P. , Klein, Christopher J.

Neurology | December 7, 2023 | Volume: 94 | Issue: 15_supplement | Pages: No page available

10.1212/wnl.94.15_supplement.2538 Get It

A Population Based Assessment of Polyneuropathy and Associated Disability (S58.003)
Hoffman, E. Matthew , Kabat, Brian, Robb, Jared M., Staff, Nathan P. , Sauver, Jennifer L. St. , Klein, Christopher J.

Neurology | December 7, 2023 | Volume: 80 | Issue: 7_supplement | Pages: No page available

10.1212/wnl.80.7_supplement.s58.003 Get It