Back to Authors

Kaufman, Kenton R.

https://orcid.org/0000-0002-7311-3781

Mayo Clinic

Mayo Clinic

Citations 96

Impact of Anterior Load Carriage on Dynamic Sagittal Spinal Alignment
Bhat, Sandesh G., Barman, Apurba, Kaufman, Kenton R , Barman, Apurba , Rezaei, Asghar , Bhat, Sandesh G. , Kaufman, Kenton R.

American Journal of Physical Medicine & Rehabilitation | August 13, 2026 | Volume: No volume available | Issue: No issue available | Pages: No page available

10.1097/phm.0000000000003128 Get It

Objectives: To examine the effects of anterior load carriage on dynamic sagittal spinal alignment during the gait cycle in younger (<65 y) and older (≥65 y) adults. Design: Cross-sectional study of 47 participants aged 20–80 years categorized as young and older adults. Participants walked at self-selected speeds with and without a 4.5 kg anterior chest load. Whole-body kinematics were recorded using a 19-camera infrared motion capture system. Outcome measures included lumbar lordosis (LL), thoracic kyphosis (TK), trunk inclination (TI), sagittal trunk shift (STS), and pelvic tilt (PT). Gait-cycle–dependent differences were analyzed using statistical parametric mapping. Results: The mean age was 41 years in young adults (n=28) and 70 years in older adults (n=19). Anterior load carriage increased LL during portions of the gait cycle and reduced TI throughout the entire gait cycle. Younger adults demonstrated greater LL and lower TI than older adults. A significant age-by-load interaction for TI was observed during portions of the gait cycle. Conclusions: Anterior load carriage alters spinal alignment by increasing LL and reducing TI during walking, with distinct age-related patterns. These results provide valuable reference data and a foundation for future studies on load management and ergonomic interventions across the adult lifespan.
Concurrent Validity and Between-System Agreement of a Commercial Wearable Inertial Sensor System for Gait and Postural Sway Assessment in Progressive Supranuclear Palsy
Novotny, Ryan , You, Sungmin , Hogen, Cecilia A., Whitwell, Jennifer L. , Josephs, Keith A. , Kaufman, Kenton R. , Ali, Farwa , Novotny, Ryan E , You, Victor S , Josephs, Keith A , Kaufman, Kenton R , Ali, Farwa

Sensors | August 12, 2026 | Volume: 26 | Issue: 16 | Pages: 5105

10.3390/s26165105 Get It

Wearable inertial measurement units (IMUs) offer an accessible alternative to optical motion capture (MoCap) gait analysis, but their performance in Progressive Supranuclear Palsy (PSP) requires validation. We assessed the concurrent validity of IMU-derived versus MoCap-derived gait metrics and static postural sway in 30 patients with PSP using Bland–Altman analysis, Intraclass Correlation Coefficients (ICC), and Spearman rank correlations. Finally, we assessed equivalence using the Two one-sided tests (TOST) procedure. Multivariable linear regression was used to determine whether clinical severity, as measured by the PSP Rating Scale (PSPRS), independently predicted absolute IMU measurement error while controlling for patient age and gait velocity. IMUs demonstrated excellent between-system agreement for parameters such as cadence (100.76 ± 11.42 vs. 100.52 ± 11.59) and cycle time (1.21 ± 0.15 vs. 1.22 ± 0.15; ICC > 0.98), despite a systematic underestimation of gait velocity (p < 0.05). Agreement significantly diminished for micro-phases (e.g., single/double support times) and spatial asymmetry. Interestingly, the TOST procedure revealed that only sagittal and transverse trunk kinematics were equivalent between systems, with all other measures failing to find equivalency. For static sway, the IMU demonstrated strong rank-order correspondence for tracking relative postural instability (ρ = 0.82, p < 0.05). Multivariable analysis revealed that higher PSPRS scores are independently associated with greater between-system discrepancies in support phases and pelvic and trunk kinematics (p < 0.05), irrespective of reduced gait speed. These findings highlight the need to develop disease-specific algorithms, rather than relying on normative commercial models, to establish reliable digital biomarkers for monitoring progressive motor decline.
Human Spastic Muscle Remodels After Surgical Hyper-Selective Neurectomy
Wang, Zheng, Pichika, Rajeswari , Rhee, Peter, Kaufman, Kenton, Lieber, Richard, Rhee, Peter C , Kaufman, Kenton R. , Lieber, Richard L.

Physiology | May 12, 2026 | Volume: 41 | Issue: S1 | Pages: No page available

10.1152/physiol.2026.41.s1.2289722 Get It

Background: Spasticity after upper motor neuron injury (stroke, spinal cord injury, etc.) alters muscle activity and induces long-term structural remodeling of skeletal muscle [1]. Elbow flexors, including the biceps brachii, are frequently affected, leading to abnormal tone, involuntary co-contraction, and impaired elbow function. Hyper-selective neurectomy (HSN) is a well-established surgical technique that has gained renewed clinical adoption with advances in anatomic understanding and intraoperative nerve mapping [2], yet its effects on muscle properties are poorly defined. Objective: The purpose of this study was to define pre- vs. post-HSN differences in muscle gene expression, sarcomere length, and clinical outcomes of the spastic human biceps. Methods: Individuals with elbow flexor spasticity undergoing a planned two-stage HSN were prospectively enrolled (n=10). Stage 1 released the elbow flexors and provided a pre-biopsy; Stage 2, performed ~3 months later to treat the forearm flexors, provided a second exposure to the biceps and a second biopsy. In both stages, biceps biopsies were obtained with customized clamps [3] at predefined elbow angles (50°, 90°, 135°), fixed, and analyzed for sarcomere length [4]. Total RNA was extracted from pre- and post-HSN biceps samples to characterize transcriptional changes. Clinical spasticity was assessed before Stage 1 and again before Stage 2 using the Modified Ashworth Scale (MAS). Data were compared using repeated-measures models, and single-cell transcriptional changes were analyzed using established analytical pipelines. Results: Sarcomere length (SL) increased significantly after HSN at all joint angles. At 50°, SL increased from 2.45 ± 0.18 µm pre-HSN to 3.05 ± 0.28 µm post-HSN; at 90°, from 2.70 ± 0.29 µm to 2.91 ± 0.16 µm; and at 135°, from 2.72 ± 0.36 µm to 3.24 ± 0.32 µm (all p < 0.05). Clinical spasticity assessment improved significantly as well (p < 0.05), with MAS scores decreasing from 1.89± 0.93 to 0.35 ± 0.53. RNA sequencing revealed changes in key pathways and overall gene expression patterns such as enhanced inflammatory response through increased cytokine production and fibroblast proliferation, leading to elevated collagen synthesis and subsequent fibrosis. We also observed upregulated immune modulation and chemotaxis, while pathways involved in mitochondrial respiration, muscle development, and cellular homeostasis were downregulated. At the transcript level, HSN led to decreased inflammation and adipogenesis, while promoting increased extracellular matrix assembly, and vascular formation. Conclusion: HSN produced coordinated improvements across structural, clinical, and transcriptional levels in the spastic human biceps muscle. Sarcomere lengths increased toward longer resting lengths at all joint angles, clinical spasticity decreased significantly, and RNA sequencing revealed distinct post-operative transcriptional remodeling. The longer sarcomere length and decreased spasticity should contribute to improved patient function after HSN. References: 1. Lieber RL et al. Muscle Nerve. 2002;26:98–105. 2. Leclercq C et al. Hand Clin. 2018;34:537–545. 3. Lieber RL et al. J Neurophysiol. 1994;71:874–881. 4. Ward SR et al. J Biomech. 2009;42:193–196. This abstract was presented at the American Physiology Summit 2026 and is only available in HTML format. There is no downloadable file or PDF version. The Physiology editorial board was not involved in the peer review process.
Percutaneous spinal stimulation to enhance gait and alleviate functional impairments in multiple sclerosis: A pilot study
Jahanian, Omid , Asp, Anders J., Gill, Megan L., Veith, Daniel D. , Fernandez, K. A. , Hogen, Cecilia A., Mills, Candee J. , Thoreson, Andrew R. , Grahn, Peter J. , Fernandez, Katrina A, Tobin, W Oliver , Fernandez, K A , Jahanian, Omid , Asp, Anders J., Solinsky, Ryan , Kaufman, Kenton R. , Zhao, Kristin D. , Tobin, W. Oliver

Multiple Sclerosis Journal – Experimental, Translational and Clinical | April 29, 2026 | Volume: 12 | Issue: 2 | Pages: No page available

10.1177/20552173261432301 Get It

Objective To evaluate the feasibility and potential efficacy of percutaneous spinal stimulation (epidural stimulation, ES) combined with task-specific training to reduce spasticity and improve gait and balance in individuals with progressive multiple sclerosis (MS). Methods Two men with progressive MS (EDSS 6.5) underwent ES lead implantation targeting the lower spinal cord, followed by one month of rehabilitation involving 12 ES-assisted training sessions. Assessments included instrumented gait analysis, Modified Ashworth Scale (MAS), pendulum test, and static balance testing performed at baseline, and at end of the study with ES-Off and ES-On conditions. Results Participant 1, with spastic hemiparetic gait, demonstrated improved lower extremity joint kinematics and muscle activation during gait, reduced knee extensor spasticity, and enhanced functional movement patterns with ES-On. Participant 2, with significant paraparesis and minimal spasticity, showed limited gait changes but experienced marked improvements in static balance, particularly under eyes-closed conditions. No adverse events were reported. Conclusion This pilot study demonstrates the feasibility and tolerability of ES paired with task-specific training in progressive MS. Participant-specific responses were observed, including improvements in gait kinematics, neuromuscular activation, spasticity, or balance; however, spatiotemporal gait parameters did not improve. These preliminary findings highlight response heterogeneity and the need for individualized ES parameter tuning. Trial registry name and URL: https://clinicaltrials.gov/study/NCT06019611
Aggregation Periods Influence Step Count Error in Low-Power Wearables
Lundell, Sydney , Kaufman, Kenton R. , Kaufman, Kenton R

Sensors | November 19, 2025 | Volume: 25 | Issue: 22 | Pages: 6998

10.3390/s25226998 Get It

Wearable sensors are increasingly used to monitor physical activity, yet low-power devices often rely on data aggregation to conserve battery life, potentially impacting measurement accuracy. This study evaluates the performance of a new low-power wearable (LPW), designed for monitoring steps across multiple months in a free-living environment, compared to a research-grade sensor (RGS) that collects raw acceleration data, with a focus on how different aggregation intervals impact step count accuracy. Thirty-two participants wore both sensors over two days, with LPW data collected in 10 min, 1 min, or 10 s aggregation periods (APs). Sensitivity and specificity of wear time detection were high across all APs (0.96 and 0.98, respectively). While total daily step count error did not differ significantly between APs, the 10 min AP exhibited greater undercounting and wider limits of agreement, especially in APs containing more than 40 steps. These findings suggest that although AP does not affect total daily step count, it influences the accuracy and variability of more granular data windows. Aggregating step counts over longer intervals may obscure short, fragmented bouts common in daily activity, leading to underestimation of steps. Optimizing APs and sensor settings is critical for improving accuracy in low-power wearables used outside laboratory settings.
Dynamic Stability Analysis of Progressive Supranuclear Palsy Affected Gait Using Lyapunov Floquet Theory
Bhat, Sandesh G. , Ali, Farwa , Hogen, Cecilia A., Rezaei, Asghar , Josephs, Keith A. , Whitwell, Jennifer L. , Bhat, Sandesh G , Whitwell, Jennifer , Kaufman, Kenton R.

IEEE Transactions on Neural Systems and Rehabilitation Engineering | September 25, 2025 | Volume: 33 | Issue: No issue available | Pages: 3958-3964

10.1109/tnsre.2025.3614555 Get It

Gait Analysis in Neurologic Disorders
Ali, Farwa , Padilla, Hannah, Blazek, Audrey M. , Barnard, Leland R , Barnard, Leland , Kaufman, Kenton R.

Neurology | September 19, 2025 | Volume: 105 | Issue: 8 | Pages: No page available

10.1212/wnl.0000000000214154 Get It

Minimal changes in excitation-contraction coupling in spastic human muscle
Wang, Zheng , Hoffman, E. Matthew , Litchy, William J. , Rhee, Peter C. , Lieber, Richard L. , Hoffman, Ernest Matthew , Rhee, Peter C , Kaufman, Kenton R , Lieber, Richard L , Shin, Alexander Y. , Kaufman, Kenton R.

Journal of Neurophysiology | September 6, 2025 | Volume: 134 | Issue: 4 | Pages: 1069-1074

10.1152/jn.00274.2025 Get It

This study presents the first in vivo intraoperative measurement of the kinetic properties of spastic human muscle. Despite slower relaxation in spastic biceps, the force-frequency relationship was similar to that of the healthy gracilis muscle. This suggests that spasticity does not substantially alter frequency-dependent force summation, possibly due to similar fiber-type compositions and limited changes in calcium handling or myosin isoforms in human spastic muscle.
Patient-reported outcome measures used in clinical trials of an elbow orthosis: A scoping review
Ninow, Hadley T., Bhat, Sandesh G. , Wilson, Gwen , Barman, Apurba, Bhat, Sandesh G , Kaufman, Kenton R , Barman, Apurba , Kaufman, Kenton R.

Prosthetics & Orthotics International | August 15, 2025 | Volume: 50 | Issue: 3 | Pages: 330-340

10.1097/pxr.0000000000000482 Get It

There is an increased clinical use of elbow orthoses. It is important to consider patient experiences in their use. Patient-reported outcome measures (PROMs) serve as essential tools for gathering patient perspectives. This review provides a comprehensive list of PROMs used in clinical trials of elbow orthoses, and documents their properties, uses, and quality. A systematic literature search across PubMed, Scopus, Embase, Cumulative Index to Nursing and Allied Health Literature, and Web of Science identified 31 clinical trials of elbow orthoses that used PROMs as outcome measures. Subsequently, manual searches were conducted to report on each PROM's characteristics. A total of 15 different PROMs were used as outcome measurements in clinical trials that used an elbow orthosis as an intervention for 11 different conditions. Researchers can use this review to aid in making informed decisions about which PROMs to use for future clinical trials.
In-vivo human gracilis muscle active force-length relationship is explained by the sliding filament theory
Wang, Zheng , Lieber, Richard L. , Binder‐Markey, Benjamin I. , Kaufman, Kenton R.

Physiology | July 1, 2025 | Volume: 40 | Issue: S1 | Pages: No page available

10.1152/physiol.2025.40.s1.0704 Get It

WITHDRAWN