Adaptation of a channelized Hotelling observer model to accommodate anthropomorphic backgrounds and moving test objects in X‐ray angiography
Gomez‐Cardona, Daniel, Favazza, Christopher , Schueler, Beth A. , Fetterly, Kenneth A. , Favazza, Christopher P, Leng, Shuai

Medical Physics | September 15, 2023 | Volume: 50 | Issue: 11 | Pages: 6737-6747

10.1002/mp.16686 Get It

AbstractBackgroundPrior implementations of the channelized Hotelling observer (CHO) model have succeeded in assessing the performance of X‐ray angiography systems under a variety of imaging conditions. However, often times these conditions do not resemble those present in routine clinical imaging scenarios, such as having complex anthropomorphic backgrounds in conjunction with moving test objects.PurposeThis work builds up on prior established CHO methods and introduces a new approach to switch from the already established “multiple‐sample” CHO implementation to a “single‐sample” technique. The proposed implementation enables the inclusion of moving test objects upon nonuniform backgrounds by allowing only a single sample to represent the test object present condition that is to be used within the statistical test to estimate the detectability index.MethodsTo assess the proposed method, two image data sets were acquired with a clinical X‐ray angiography system. The first set consisted of a uniform background in combination with static test objects while the second consisted of an anthropomorphic chest phantom in conjunction with moving test objects. The first set was used to validate the proposed approach against the multiple‐sample method while the second was used to assess the feasibility of the proposed method under a variety of imaging conditions, including seven object sizes and seven detector target dose (DTD) levels.ResultsFor the uniform background data set, considering all detectability indices greater or equal than 1, the ratio between the detectability indices of the proposed single‐sample approach versus the multiple‐sample method was 0.997 ± 0.056 (range 0.884–1.159). The average single‐direction width of the 95% confidence intervals (CIs) of the detectability index estimates for the multiple‐sample method was 0.38 ± 0.43 (range 0.03–2.20). For the single‐sample approach, the average width was 2.52 ± 0.63 (range 1.11–5.44). For the anthropomorphic background image set, the results were consistent with classical quantum‐limited signal‐to‐noise ratio (SNR) theory. The magnitude of the detectability indices varied predictably with changes in both object size and DTD, with the highest value associated with the highest dose and the largest object size. Additionally, the proposed method was able to capture differences in the imaging performance for a given test object across the field of view, which was associated with the attenuation levels provided by different features of the anthropomorphic background.ConclusionsA new single‐sample variant of the CHO model to assess the performance of X‐ray angiography imaging systems is proposed. The new approach is consistent with quantum‐limited image quality theory and with a standard implementation of the CHO model. The proposed method enables the assessment of moving test objects in combination with complex, nonuniform image backgrounds, thereby opening the possibility to assess imaging conditions which more closely resemble those used in clinical care.
Task‐specific efficient channel selection and bias management for Gabor function channelized Hotelling observer model for the assessment of x‐ray angiography system performance
Gomez‐Cardona, Daniel, Favazza, Christopher , Schueler, Beth A. , Fetterly, Kenneth A. , Favazza, Christopher P, Leng, Shuai

Medical Physics | March 3, 2021 | Volume: 48 | Issue: 7 | Pages: 3638-3653

10.1002/mp.14813 Get It

PurposeChannelized Hotelling observer (CHO) models have been implemented to assess imaging performance in x‐ray angiography systems. While current methods are appropriate for assessing unprocessed images of moving test objects upon uniform‐exposure backgrounds, they are inadequate for assessing conditions which more appropriately mimic clinical imaging conditions including the combination of moving test objects, complex anthropomorphic backgrounds, and image processing. In support of this broad goal, the purpose of this work was to develop theory and methods to automatically select a subset of task‐specific efficient Gabor channels from a task‐generic Gabor channel base set. Also, previously described theory and methods to manage detectability index (d′) bias due to nonrandom temporal variations in image electronic noise will be revisited herein.MethodsStarting with a base set of 96 Gabor channels, backward elimination of channels was used to automatically identify an “efficient” channel subset which reduced the number of channels retained in the subset while maintaining the magnitude of the d′ estimate. The concept of a pixelwise Hotelling observer (PHO) model was introduced and similarly implemented to assess the performance of the efficient‐channel CHO model. Bias in d′ estimates arising from temporally variable nonstationary noise was modeled as a bivariate probability density function for normal distributions, where one variable corresponds to the signal from the test object and the other variable corresponds to the signal from temporally variable nonstationary noise. Theory and methods were tested on uniform‐exposure unprocessed angiography images with detector target dose (DTD) of 6, 18, and 120 nGy containing static disk‐shaped test objects with diameter in the range of 0.5 to 4 mm.ResultsConsidering all DTD levels and test object sizes, the proposed method reduced the number of Gabor channels in the final subset by 63–82% compared to the original 96 Gabor channel base set, while maintaining a mean relative performance () of 95% 4% with respect to the reference PHO model. Experimental results demonstrated that the bivariate approach to account for bias due to temporally variable nonstationary noise resulted in improved correlation between the CHO and PHO models as compared to a previously proposed univariate approach.ConclusionsComputationally efficient backward elimination can be used to select an efficient subset of Gabor channels from an initial channel base set without substantially compromising the magnitude of the d′ estimate. Bias due to temporally variable nonstationary noise can be modeled through a bivariate approach leading to an improved unbiased estimate of d′.
Small (< 4 cm) Renal Masses: Differentiation of Angiomyolipoma Without Visible Fat From Renal Cell Carcinoma Using Unenhanced and Contrast-Enhanced CT
Takahashi, Naoki , Kitajima, Kazuhiro , Gomez‐Cardona, Daniel, Thapa, Prabin , Carter, Rickey E. , Leibovich, Bradley C. , Sasiwimonphan, Kewalee , Sasaguri, Kohei, Gomez-Cardona, Daniel, Leng, Shuai , Kawashima, Akira , Carter, Rickey E , Takahashi, Naoki

American Journal of Roentgenology | November 20, 2015 | Volume: 205 | Issue: 6 | Pages: 1194-1202

10.2214/ajr.14.14183 Get It

Small (< 4 cm) Renal Mass: Differentiation of Oncocytoma From Renal Cell Carcinoma on Biphasic Contrast-Enhanced CT
Sasaguri, Kohei, Takahashi, Naoki , Gomez‐Cardona, Daniel, Schmit, Grant D. , Carter, Rickey E. , Leibovich, Bradley C. , Leng, Shuai , Kawashima, Akira , Carter, Rickey E , Takahashi, Naoki

American Journal of Roentgenology | October 24, 2015 | Volume: 205 | Issue: 5 | Pages: 999-1007

10.2214/ajr.14.13966 Get It