Back to Authors

Bedogni, Francesco

0000-0002-4975-6605

Mayo Clinic

IRCCS Policlinico San Donato

Citations 2

Methods for improved bileaflet aortic valve detection prior to transcatheter aortic valve replacement
Tretter, Justin T. , Eleid, Mackram F., Bedogni, Francesco, Rodés-Cabau, Josep, Regueiro, Ander, Testa, Luca, Ellenbogen, Kenneth A., Leon, M B, Ben-Haim, Shlomo, Eleid, Mackram F. , Bedogni, Francesco , Rodés‐Cabau, Josep , Regueiro, Ander , Testa, Luca , Chen, Shmuel , Galhardo, Attílio , Ellenbogen, Kenneth A , Leon, Martin B.

Frontiers in Cardiovascular Medicine | February 23, 2026 | Volume: 13 | Issue: No issue available | Pages: No page available

10.3389/fcvm.2026.1755835 Get It

Background Bileaflet aortic valve prevalence in transcatheter aortic valve replacement (TAVR) patients is poorly defined. We evaluated a TAVR cohort to determine the bileaflet aortic valve prevalence and understand features which may improve detection. In addition, we related valvar morphology to the occurrence of permanent pacemaker implantation (PPI) following TAVR. Methods Aortic valvar morphology diagnosis was recorded from the pre-procedural cardiac CTA reports prior to TAVR. Commissural angles, comparison of commissural heights, and dynamic visual inspection of the aortic valve were subsequently evaluated on pre-procedural cardiac CTA by an expert cardiac anatomist and imager, methods previously validated in a surgical cohort, to determine aortic valvar morphology and compared to the historical diagnosis. Relationships between valvar morphological characteristics with the need for PPM within 30-days post-TAVR were determined. Results Four-hundred and thirty-three (mean age 81.3 ± 6.6 years, 53.8% female) underwent TAVR [corrected diagnosis: 393 (90.8%) trileaflet vs. 40 (9.2%) bileaflet valves]. Bileaflet valves were historically misdiagnosed in 80% of pre-procedural cardiac CTA reports. Thirty-four (85.0%) had intercoronary leaflet fusion [mean commissural angle = 148.1 (18.3) degrees]. A commissural angle threshold of 141.1 degrees had a sensitivity of 0.73 and specificity of 0.86 for identifying a bileaflet valve. PPI post-TAVR occurred in 38% bileaflet vs. 19% trileaflet patients ( p = 0.0114 ) [unadjusted OR for bileaflet valve requiring PPI = 2.54, 95% CI (1.25–5.01)]. Conclusions Bileaflet aortic valves are commonly misdiagnosed. Assessment of the commissural angle and comparison of commissural heights may improve CTA-based diagnostic accuracy prior to TAVR. Improved detection may guide improved outcomes in this higher risk population.
Three‐Year Outcomes With a Supra‐Annular, Self‐Expanding Bioprosthesis and a Pericardial Wrap—The FORWARD PRO Study
Mieghem, Nicolas M. Van , Manoharan, Ganesh, Lancellotti, Patrizio , Danenberg, Haim , Scholtz, Werner , Brecker, Stephen , Ruge, Hendrik, Opdahl, Anders , Amoroso, Giovanni , Petronio, Anna Sonia , Nickenig, Georg, Harnath, Axel, Oh, Jae K. , Eisenberg, Ruth , Grube, Eberhard, Ruge, Hendrik , Van Mieghem, Nicolas M , Kornowski, Ran , Bedogni, Francesco , Windecker, Stephan , Tamburino, Corrado , Thiele, Hölger , Fiorina, Claudia , Kempfert, Jörg

Catheterization and Cardiovascular Interventions | December 17, 2024 | Volume: 105 | Issue: 3 | Pages: 577-587

10.1002/ccd.31335 Get It

ABSTRACTBackgroundThe self‐expanding, supra‐annular Evolut valve is an established platform for Transcatheter Aortic Valve Implantation (TAVI). Evolut PRO introduced an outer sealing wrap to mitigate paravalvular leakage. We evaluated the 3‐year clinical outcomes and valve performance of the Evolut PRO in standard clinical practice for severe aortic stenosis (AS) patients at intermediate or higher risk for surgery.MethodsThe FORWARD PRO prospective, single‐arm, multicentre, post‐market clinical study enrolled 638 patients with native aortic valve stenosis or failed surgical bioprosthetic aortic valve undergoing TAVI, at intermediate or high risk, with the Evolut PRO valve. Clinical and serial echocardiographic outcomes were followed‐up for 3 years.ResultsTAVI using Evolut PRO was attempted in 629 AS patients (implanted in 97%) (mean age 81.7 years; STS PROM score, 4.7%). At 3 years all‐cause mortality was 25.0%, disabling stroke 6.5% (all‐cause mortality or disabling stroke, 28.5%) and rate of new permanent pacemaker implantation 24.7%. Excellent valve haemodynamics were maintained (mean gradient 8.8 ± 4.7 mm Hg; mean effective orifice area 2.0 ± 0.5 cm2) at 3 years. In a paired analysis of patients with ≥ mild paravalvular leakage (PVL) at discharge, more than two‐thirds demonstrated improved PVL at 3 years. Patients with ≥ mild PVL at discharge had higher median total calcium volume than those with no/trace PVL (p < 0.001).ConclusionsIn clinical practice TAVI with the Evolut PRO valve is associated with favorable clinical outcomes and excellent haemodynamic performance out to 3 years. The observation of improvements in PVL over time warrants further research.