Van Mieghem, Nicolas M

0000-0002-2732-1205

Mayo Clinic

Erasmus MC

Citations 5

Coronary Stent Imaging with Photon-counting Detector CT
Bie, Judith van der , Sharma, Simran P., Hirsch, Alexander , Boccalini, Sara , Mieghem, Nicolas M. Van , Dijkshoorn, Marcel L., Booij, Ronald , Straten, Marcel van , Bos, Daniël , van der Bie, Judith , Sharma, Simran Priyanka , Van Mieghem, Nicolas M , van Straten, Marcel , Rajiah, Prabhakar , Budde, Ricardo Peter Jurgen , Rajiah, Prabhakar , Budde, Ricardo P.J.

Radiology: Cardiothoracic Imaging | May 29, 2025 | Volume: 7 | Issue: 3 | Pages: No page available

10.1148/ryct.240338 Get It

Photon-counting detector CT offers improved assessment of small stents and higher diagnostic accuracy than conventional CT through enhanced spatial resolution and spectral reconstructions.
Three‐Year Outcomes With a Supra‐Annular, Self‐Expanding Bioprosthesis and a Pericardial Wrap—The FORWARD PRO Study
Mieghem, Nicolas M. Van , Manoharan, Ganesh, Lancellotti, Patrizio , Danenberg, Haim , Scholtz, Werner , Brecker, Stephen , Ruge, Hendrik, Opdahl, Anders , Amoroso, Giovanni , Petronio, Anna Sonia , Nickenig, Georg, Harnath, Axel, Oh, Jae K. , Eisenberg, Ruth , Grube, Eberhard, Ruge, Hendrik , Van Mieghem, Nicolas M , Kornowski, Ran , Bedogni, Francesco , Windecker, Stephan , Tamburino, Corrado , Thiele, Hölger , Fiorina, Claudia , Kempfert, Jörg

Catheterization and Cardiovascular Interventions | December 17, 2024 | Volume: 105 | Issue: 3 | Pages: 577-587

10.1002/ccd.31335 Get It

ABSTRACTBackgroundThe self‐expanding, supra‐annular Evolut valve is an established platform for Transcatheter Aortic Valve Implantation (TAVI). Evolut PRO introduced an outer sealing wrap to mitigate paravalvular leakage. We evaluated the 3‐year clinical outcomes and valve performance of the Evolut PRO in standard clinical practice for severe aortic stenosis (AS) patients at intermediate or higher risk for surgery.MethodsThe FORWARD PRO prospective, single‐arm, multicentre, post‐market clinical study enrolled 638 patients with native aortic valve stenosis or failed surgical bioprosthetic aortic valve undergoing TAVI, at intermediate or high risk, with the Evolut PRO valve. Clinical and serial echocardiographic outcomes were followed‐up for 3 years.ResultsTAVI using Evolut PRO was attempted in 629 AS patients (implanted in 97%) (mean age 81.7 years; STS PROM score, 4.7%). At 3 years all‐cause mortality was 25.0%, disabling stroke 6.5% (all‐cause mortality or disabling stroke, 28.5%) and rate of new permanent pacemaker implantation 24.7%. Excellent valve haemodynamics were maintained (mean gradient 8.8 ± 4.7 mm Hg; mean effective orifice area 2.0 ± 0.5 cm2) at 3 years. In a paired analysis of patients with ≥ mild paravalvular leakage (PVL) at discharge, more than two‐thirds demonstrated improved PVL at 3 years. Patients with ≥ mild PVL at discharge had higher median total calcium volume than those with no/trace PVL (p < 0.001).ConclusionsIn clinical practice TAVI with the Evolut PRO valve is associated with favorable clinical outcomes and excellent haemodynamic performance out to 3 years. The observation of improvements in PVL over time warrants further research.
Three-Year Outcomes Following TAVR in Younger (
Modine, Thomas , Tchétché, Didier , Mieghem, Nicolas M. Van , Deeb, G. Michael , Chetcuti, Stanley, Yakubov, Steven J. , Sorajja, Paul , Gada, Hemal, Mumtaz, Mubashir , Ramlawi, Basel , Bajwa, Tanvir , Crouch, John , Teirstein, Paul S., Kleiman, Neal S. , Iskander, Ayman, Chu, Michael , Sudre, Arnaud , Huang, Jian, Popma, Jeffrey J. , Forrest, John K. , Van Mieghem, Nicolas M , Bagur, Rodrigo , Chu, Michael W A , Berthoumieu, Pierre , Sudre, Arnaud , Adrichem, Rik , Ito, Saki , Forrest, John K , Modine, Thomas , Sorajja, Paul , Bagur, Rodrigo , Ito, Saki , Huang, Jian Qun , Reardon, Michael J.

Circulation: Cardiovascular Interventions | October 18, 2024 | Volume: 17 | Issue: 11 | Pages: No page available

10.1161/circinterventions.124.014018 Get It

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis, but data are limited on younger, low-risk patients. This analysis compares outcomes in low-surgical-risk patients aged <75 years receiving TAVR versus surgery. METHODS: The Evolut Low Risk Trial randomized 1414 low-risk patients to treatment with a supra-annular, self-expanding TAVR or surgery. We compared rates of all-cause mortality or disabling stroke, associated clinical outcomes, and bioprosthetic valve performance at 3 years between TAVR and surgery patients aged <75 years. RESULTS: In patients <75 years, 352 were randomized to TAVR and 351 to surgery. Mean age was 69.1±4.0 years (minimum 51 and maximum 74); Society of Thoracic Surgeons Predicted Risk of Mortality was 1.7±0.6%. At 3 years, all-cause mortality or disabling stroke for TAVR was 5.7% and 8.0% for surgery ( P =0.241). Although there was no difference between TAVR and surgery in all-cause mortality, the incidence of disabling stroke was lower with TAVR (0.6%) than surgery (2.9%; P =0.019), while surgery was associated with a lower incidence of pacemaker implantation (7.1%) compared with TAVR (21.0%; P <0.001). Valve reintervention rates (TAVR 1.5%, surgery 1.5%, P =0.962) were low in both groups. Valve performance was significantly better with TAVR than surgery with lower mean aortic gradients ( P <0.001) and lower rates of severe prosthesis-patient mismatch ( P <0.001). Rates of valve thrombosis and endocarditis were similar between groups. There were no significant differences in rates of residual ≥moderate paravalvular regurgitation. CONCLUSIONS: Low-risk patients <75 years treated with supra-annular, self-expanding TAVR had comparable 3-year all-cause mortality and lower disabling stroke compared with patients treated with surgery. There was significantly better valve performance in patients treated with TAVR. REGISTRATION: URL: https://clinicaltrials.gov ; Unique identifier: NCT02701283.
Invasive Right Ventricular Pressure-Volume Analysis: Basic Principles, Clinical Applications, and Practical Recommendations
Brener, Michael I. , Masoumi, Amirali, Ng, Vivian G., Tello, Khodr , Bastos, Marcelo B. , Cornwell, William K. , Hsu, Steven , Tedford, Ryan J. , Lurz, Philipp , Rommel, Karl-Philipp , Kresoja, Karl-Patrik , Nagueh, Sherif F. , Kanwar, Manreet , Kapur, Navin K. , Hiremath, Gurumurthy , Sarraf, Mohammad, Enden, Antoon J.M. Van Den, Heerdt, Paul M., Kodali, Susheel K., Uriel, Nir , Kanwar, Manreet K , Van Mieghem, Nicolas M , Hahn, Rebecca T , Sayer, Gabriel T , Uriel, Nir , Burkhoff, Daniel , Lurz, Philipp , Tedford, Ryan J , Brener, Michael I. , Masoumi, Amirali, Ng, Vivian G., Tello, Khodr , Bastos, Marcelo B. , Cornwell, William K. , Hsu, Steven , Rommel, Karl-Philipp , Kresoja, Karl-Patrik , Nagueh, Sherif F. , Kapur, Navin K , Hiremath, Gurumurthy , Sarraf, Mohammad, Enden, Antoon J.M. Van Den, Heerdt, Paul M., Kodali, Susheel K.

Circulation: Heart Failure | December 29, 2021 | Volume: 15 | Issue: 1 | Pages: No page available

10.1161/circheartfailure.121.009101 Get It

Right ventricular pressure-volume (PV) analysis characterizes ventricular systolic and diastolic properties independent of loading conditions like volume status and afterload. While long-considered the gold-standard method for quantifying myocardial chamber performance, it was traditionally only performed in highly specialized research settings. With recent advances in catheter technology and more sophisticated approaches to analyze PV data, it is now more commonly used in a variety of clinical and research settings. Herein, we review the basic techniques for PV loop measurement, analysis, and interpretation with the aim of providing readers with a deeper understanding of the strengths and limitations of PV analysis. In the second half of the review, we detail key scenarios in which right ventricular PV analysis has influenced our understanding of clinically relevant topics and where the technique can be applied to resolve additional areas of uncertainty. All told, PV analysis has an important role in advancing our understanding of right ventricular physiology and its contribution to cardiovascular function in health and disease.
Final 3‐year clinical outcomes following transcatheter aortic valve implantation with a supra‐annular self‐expanding repositionable valve in a real‐world setting: Results from the multicenter FORWARD study
Mieghem, Nicolas M. Van , Windecker, Stephan , Manoharan, Ganesh, Bosmans, Johan, Modine, Thomas , Linke, Axel, Scholtz, Werner , Tchétché, Didier , Finkelstein, Ariel, Eisenberg, Ruth , Grube, Eberhard, Van Mieghem, Nicolas M , Modine, Thomas , Ito, Saki , Windecker, Stephan , Bleiziffer, Sabine

Catheterization and Cardiovascular Interventions | July 31, 2021 | Volume: 99 | Issue: 1 | Pages: 171-178

10.1002/ccd.29889 Get It

AbstractObjectivesThe Evolut R FORWARD study confirmed safety and effectivenesss of the Evolut R THV in routine clinical practice out to 1 year. Herein, we report the final 3‐year clinical follow up of the FORWARD study.BackgroundTranscatheter aortic valve replacement (TAVR) is a proven alternative to surgery in elderly patients with symptomatic severe aortic stenosis. Long‐term clinical outcome data with the Evolut R platform are scarce.MethodsFORWARD is a prospective multicenter observational study that evaluated the Evolut R system in routine clinical practice at 53 centres. Eligible patients had symptomatic native aortic valve stenosis or failed surgical aortic bioprosthesis and elevated operative risk per Heart‐Team assessment. TAVR was attempted in 1039 patients.ResultsMean age was 81.8 ± 6.2 years, 64.9% were women, STS score was 5.5 ± 4.5% and 34.2% were frail. Rates of all‐cause mortality and disabling stroke were 24.8% and 4.8% at 3 years. Early need for a new pacemaker implantation after TAVR (all‐cause mortality: with new PPI; 21.0% vs. without; 22.8%, p = 0.55) and the presence of > trace paravalvular regurgitation (all‐cause mortality: no or trace; 22.0% vs. ≥ mild; 25.5%, p = 0.29) did not affect survival. Between 1 and 3 years incidence rates of valve related intervention, endocarditis and clinically relevant valve thrombosis were low.ConclusionsThe Evolut R valve maintained a favorable safety profile through 3 years in routine clinical practice. Rates of transcatheter heart valve‐related adverse events were low.