Department of Cardiovascular Surgery, CHRU de Lille, Lille, France.
Citations 4
Five-year outcomes of transcatheter mitral valve replacement in patients with severe symptomatic mitral regurgitation: results from the Tendyne Expanded Clinical Study
Abstract Aims Transcatheter mitral valve replacement (TMVR) with the Tendyne Mitral Valve System is a treatment option for patients with severe symptomatic mitral regurgitation (MR) unsuitable for conventional mitral valve surgery or transcatheter edge-to-edge repair (TEER). This study sought to evaluate the safety and effectiveness of TMVR through 5-year follow-up. Methods and Results The Tendyne Expanded Clinical Study is a prospective, single-arm, multicentre study that enrolled patients between November 2014 and June 2020. The study enrolled 191 patients (mean age 74.1 ± 8.0 years, 62.8% male, 70.2% New York Heart Association Class (NYHA) class III/IV, 88.5% secondary MR), of whom 186 (97.4%) underwent TMVR with Tendyne. MR grade decreased from ≥3+ in 99.5% patients at baseline to grade ≤1+ in 95.3% at 5 years. In those patients surviving to 5 years (n = 49), durable symptomatic improvement was evidenced by 73.5% patients being in NYHA class I/II at 5 years. The Kansas City Cardiomyopathy Questionnaire overall summary score increased from 48.5 ± 22.5 points at baseline to 67.6 ± 21.5 points at 5 years. Serious adverse events that occurred through 5 years included life-threatening bleeding (11.5%), fatal bleeding (2.6%), renal insufficiency/failure (28.8%), endocarditis (7.3%), device thrombosis (5.8%), and new onset atrial fibrillation (13.1%). No structural device degeneration or device embolism occurred through 5 years. Conclusions The Tendyne TMVR was effective at achieving immediate and sustainable elimination of MR, which was associated with symptomatic improvement and absence of structural valve degeneration in a high-risk cohort over 5 years. These findings support TMVR with the Tendyne System as an alternative for patients with appropriate mitral valve anatomy and symptomatic secondary MR unsuitable for mitral surgery or TEER.
BACKGROUND: Transcatheter aortic valve replacement (TAVR) is an alternative to surgery in patients with severe aortic stenosis, but data are limited on younger, low-risk patients. This analysis compares outcomes in low-surgical-risk patients aged <75 years receiving TAVR versus surgery. METHODS: The Evolut Low Risk Trial randomized 1414 low-risk patients to treatment with a supra-annular, self-expanding TAVR or surgery. We compared rates of all-cause mortality or disabling stroke, associated clinical outcomes, and bioprosthetic valve performance at 3 years between TAVR and surgery patients aged <75 years. RESULTS: In patients <75 years, 352 were randomized to TAVR and 351 to surgery. Mean age was 69.1±4.0 years (minimum 51 and maximum 74); Society of Thoracic Surgeons Predicted Risk of Mortality was 1.7±0.6%. At 3 years, all-cause mortality or disabling stroke for TAVR was 5.7% and 8.0% for surgery ( P =0.241). Although there was no difference between TAVR and surgery in all-cause mortality, the incidence of disabling stroke was lower with TAVR (0.6%) than surgery (2.9%; P =0.019), while surgery was associated with a lower incidence of pacemaker implantation (7.1%) compared with TAVR (21.0%; P <0.001). Valve reintervention rates (TAVR 1.5%, surgery 1.5%, P =0.962) were low in both groups. Valve performance was significantly better with TAVR than surgery with lower mean aortic gradients ( P <0.001) and lower rates of severe prosthesis-patient mismatch ( P <0.001). Rates of valve thrombosis and endocarditis were similar between groups. There were no significant differences in rates of residual ≥moderate paravalvular regurgitation. CONCLUSIONS: Low-risk patients <75 years treated with supra-annular, self-expanding TAVR had comparable 3-year all-cause mortality and lower disabling stroke compared with patients treated with surgery. There was significantly better valve performance in patients treated with TAVR. REGISTRATION: URL: https://clinicaltrials.gov ; Unique identifier: NCT02701283.
Benefit of isolated surgical valve repair or replacement for functional tricuspid regurgitation and long-term outcomes stratified by the TRI-SCORE
Abstract Background and Aims Severe tricuspid regurgitation is associated with increased mortality rates, but benefit of its correction and ideal timing are not clearly determined. This study aimed to identify patient subsets who might benefit from the surgery. Methods In TRIGISTRY, an international cohort study of consecutive patients with severe isolated functional tricuspid regurgitation (33 centres, 10 countries), survival rates up to 10 years were compared between patients who underwent isolated tricuspid valve surgery (repair or replacement) and those conservatively managed, overall and according to TRI-SCORE category (low: ≤3, intermediate: 4–5, and high: ≥6). Results One thousand and two hundred seventeen were managed conservatively, and 551 underwent isolated tricuspid valve surgery (200 repairs and 351 replacements). TRI-SCORE distribution was 33% low, 32% intermediate, and 35% high. At 10 years, survival rates were similar between surgical and conservative management [41% vs. 36%; hazard ratio (HR) .97; 95% confidence interval (CI) .88–1.08, P = .57]. Surgery improved survival compared with conservative management in the low TRI-SCORE category (72% vs. 44%; HR .27; 95% CI .20–.37, P < .0001), but not in the intermediate (36% vs. 37%; HR 1.17; 95%CI .98–1.40, P = .09) or high categories (20% vs. 24%; HR 1.06; 95% CI .91–1.25, P = .45). Both repair and replacement improved survival in the low TRI-SCORE category (84% and 61% vs. 44%; HR .11; 95% CI .06–.19, P < .0001, and HR .65; 95% CI .47–.90, P = .009). Repair showed benefit in the intermediate category (59% vs. 37%; HR .49; 95% CI .35–.68, P < .0001) while replacement was possibly harmful (25% vs. 37%; HR 1.43; 95% CI 1.18–1.72, P = .0002). Conclusions Higher survival rates were observed with repair than replacement and benefit of intervention declined as TRI-SCORE increased with no benefit of any type of surgery in the high TRI-SCORE category. These results emphasize the importance of timely intervention and patient selection to achieve the best outcomes and the need for randomized controlled trials.
Final 3‐year clinical outcomes following transcatheter aortic valve implantation with a supra‐annular self‐expanding repositionable valve in a real‐world setting: Results from the multicenter FORWARD study
AbstractObjectivesThe Evolut R FORWARD study confirmed safety and effectivenesss of the Evolut R THV in routine clinical practice out to 1 year. Herein, we report the final 3‐year clinical follow up of the FORWARD study.BackgroundTranscatheter aortic valve replacement (TAVR) is a proven alternative to surgery in elderly patients with symptomatic severe aortic stenosis. Long‐term clinical outcome data with the Evolut R platform are scarce.MethodsFORWARD is a prospective multicenter observational study that evaluated the Evolut R system in routine clinical practice at 53 centres. Eligible patients had symptomatic native aortic valve stenosis or failed surgical aortic bioprosthesis and elevated operative risk per Heart‐Team assessment. TAVR was attempted in 1039 patients.ResultsMean age was 81.8 ± 6.2 years, 64.9% were women, STS score was 5.5 ± 4.5% and 34.2% were frail. Rates of all‐cause mortality and disabling stroke were 24.8% and 4.8% at 3 years. Early need for a new pacemaker implantation after TAVR (all‐cause mortality: with new PPI; 21.0% vs. without; 22.8%, p = 0.55) and the presence of > trace paravalvular regurgitation (all‐cause mortality: no or trace; 22.0% vs. ≥ mild; 25.5%, p = 0.29) did not affect survival. Between 1 and 3 years incidence rates of valve related intervention, endocarditis and clinically relevant valve thrombosis were low.ConclusionsThe Evolut R valve maintained a favorable safety profile through 3 years in routine clinical practice. Rates of transcatheter heart valve‐related adverse events were low.