Five-year outcomes of transcatheter mitral valve replacement in patients with severe symptomatic mitral regurgitation: results from the Tendyne Expanded Clinical Study
Abstract Aims Transcatheter mitral valve replacement (TMVR) with the Tendyne Mitral Valve System is a treatment option for patients with severe symptomatic mitral regurgitation (MR) unsuitable for conventional mitral valve surgery or transcatheter edge-to-edge repair (TEER). This study sought to evaluate the safety and effectiveness of TMVR through 5-year follow-up. Methods and Results The Tendyne Expanded Clinical Study is a prospective, single-arm, multicentre study that enrolled patients between November 2014 and June 2020. The study enrolled 191 patients (mean age 74.1 ± 8.0 years, 62.8% male, 70.2% New York Heart Association Class (NYHA) class III/IV, 88.5% secondary MR), of whom 186 (97.4%) underwent TMVR with Tendyne. MR grade decreased from ≥3+ in 99.5% patients at baseline to grade ≤1+ in 95.3% at 5 years. In those patients surviving to 5 years (n = 49), durable symptomatic improvement was evidenced by 73.5% patients being in NYHA class I/II at 5 years. The Kansas City Cardiomyopathy Questionnaire overall summary score increased from 48.5 ± 22.5 points at baseline to 67.6 ± 21.5 points at 5 years. Serious adverse events that occurred through 5 years included life-threatening bleeding (11.5%), fatal bleeding (2.6%), renal insufficiency/failure (28.8%), endocarditis (7.3%), device thrombosis (5.8%), and new onset atrial fibrillation (13.1%). No structural device degeneration or device embolism occurred through 5 years. Conclusions The Tendyne TMVR was effective at achieving immediate and sustainable elimination of MR, which was associated with symptomatic improvement and absence of structural valve degeneration in a high-risk cohort over 5 years. These findings support TMVR with the Tendyne System as an alternative for patients with appropriate mitral valve anatomy and symptomatic secondary MR unsuitable for mitral surgery or TEER.
Multimodality imaging of the tricuspid valve with implication for percutaneous repair approaches
Nowadays some percutaneous options for tricuspid valve (TV) repair are available: Tricinch (4Tech Cardio, Galway, Ireland) mimicking the Kay procedure, Trialign (Mitralign, Boston, MA, USA) aiming to bicuspidise TV, MitraClip (Abbott Vascular, Abbott Park, Illinois, USA) mimicking Alfieri’s stitch, direct transcatheter annuloplasty with Cardioband (Valtech Cardio, Or Yehuda, Israel) and transcatheter Forma Repair (Edwards Lifesciences, Irvine, California, USA) providing a surface for leaflet coaptation. A multimodality imaging approach is fundamental for defining the pathophysiology of tricuspid regurgitation (TR), preprocedural planning and intraprocedural monitoring. Both 2-dimensional and 3-dimensional (3D) transthoracic echocardiography and transoesophageal echocardiography (TOE) are essential for grading and anatomical characterisation of TR, and evaluation of dimensions and function of right ventricle (RV) and estimation of pulmonary pressure. In particular, 3D echocardiography provides a better anatomical definition of TV apparatus and tricuspid annulus (TA) and additional information about the anatomical relationships of TV and surrounding structures. CT offers complementary information during the preprocedural planning especially for procedures targeting TA such as annular structure and dimensions, quality and amount of annular tissue and its relationship with the right coronary artery, and the sizing of the inferior vena cava. Moreover, appropriate patient selection is crucial. The best candidate seems to be a patient with functional TR due to predominant annular dilatation with modest apical tethering, at least partial preservation of leaflets coaptation, not severe pulmonary hypertension and not advanced RV dilation and dysfunction. An example of intraprocedural multimodality imaging approach with TOE, fluoroscopy, angiography and intracardiac echocardiography is also reported.