Back to Authors

Grubb, Kendra J

0000-0002-1369-5521

Mayo Clinic

Emory University

Citations 4

Transcatheter Aortic Valve Implantation by Valve Type in Women With Small Annuli
Tchétché, Didier , Blackman, Daniel J. , Khalil, Ramzi F., Möllmann, Helge , Abdel‐Wahab, Mohamed , Ali, Walid Ben, Mahoney, Paul, Ruge, Hendrik, Lin, Lang, Byku, Isida , Gillam, Linda D. , Petronio, Anna Sonia , Attizzani, Guilherme F. , Batchelor, Wayne , Gada, Hemal, Rovin, Joshua D. , Benton, Stewart M., Gardner, Blake, Padang, Ratnasari , Herrmann, Howard C., Ruge, Hendrik , Ali, Walid Ben , Mehran, Roxana , Khalil, Ramzi F. , Bleiziffer, Sabine , Szerlip, Molly , Grubb, Kendra J , Guerrero, Mayra , Rogers, Toby , Whisenant, Brian K. , Althouse, Andrew D. , Herrmann, Howard C.

JAMA Cardiology | October 9, 2024 | Volume: 9 | Issue: 12 | Pages: 1106

10.1001/jamacardio.2024.3241 Get It

Importance Historically, women with aortic stenosis have experienced worse outcomes and inadequate recognition compared to men, being both underdiagnosed and undertreated, while also facing underrepresentation in clinical trials. Objective To determine whether women with small aortic annuli undergoing transcatheter aortic valve replacement have better clinical and hemodynamic outcomes with a self-expanding valve (SEV) or balloon-expandable valve (BEV). Design, Setting, Participants The Small Annuli Randomized to Evolut or SAPIEN Trial (SMART) was a large-scale randomized clinical trial focusing on patients with small aortic annuli undergoing transcatheter aortic valve replacement, randomized to receive SEVs or BEVs and included 716 patients treated at 83 centers in Canada, Europe, Israel, and the US from April 2021 to October 2022. This prespecified secondary analysis reports clinical and hemodynamic findings for all 621 women enrolled in SMART. Data for this report were analyzed from February to April 2024. Interventions Transcatheter aortic valve replacement with an SEV or a BEV. Main Outcomes and Measures The composite coprimary clinical end point comprised death, disabling stroke, or heart failure–related rehospitalization. The coprimary valve function end point was the incidence of bioprosthetic valve dysfunction, both assessed through 12 months. Secondary end points included the incidence of moderate or severe prosthesis-patient mismatch. Results A total of 621 women (mean [SD] age, 80.2 [6.2] years; 312 randomized to the SEV group and 309 to the BEV group) were included in the present analysis. At 12 months, there were no significant differences in the coprimary clinical end point between the SEV and BEV groups (9.4% vs 11.8%, absolute risk difference −2.3%; 95% CI −7.2 to 2.5, P = .35). However, SEV implantation was associated with less bioprosthetic valve dysfunction (8.4% vs 41.8%; absolute risk difference, −33.4%; 95% CI, −40.4 to −26.4; P < .001). SEV implantation resulted in lower aortic valve gradients and larger effective orifice areas at 30 days and 12 months and less mild or greater aortic regurgitation at 12 months compared to BEV implantation. Prosthesis-patient mismatch was significantly lower with SEVs, regardless of the definition used and adjustment for body mass index. Use of SEVs was associated with better quality of life outcomes as assessed by the Valve Academic Research Consortium-3 ordinal quality of life measure. Conclusions and Relevance Among women with severe symptomatic aortic stenosis and small aortic annuli undergoing transcatheter aortic valve replacement, the use of SEVs, compared to BEVs, resulted in similar clinical outcomes and a markedly reduced incidence of bioprosthetic valve dysfunction through 12 months, including a lower risk of prosthesis-patient mismatch and better 12-month quality of life. Trial Registration ClinicalTrials.gov Identifier: NCT04722250
Moderate Aortic Valve Stenosis Is Associated With Increased Mortality Rate and Lifetime Loss: Systematic Review and Meta‐Analysis of Reconstructed Time‐to‐Event Data of 409 680 Patients
Jacquemyn, Xander , Strom, Jordan B. , Strange, Geoff , Playford, David , Stewart, Simon , Kutty, Shelby , Bhatt, Deepak L. , Bleiziffer, Sabine , Pellikka, Patricia A. , Pîbarot, Philippe , Grubb, Kendra J , Pellikka, Patricia A , Clavel, Marie-Annick , Pibarot, Phillippe , Mentias, Amgad , Serna-Gallegos, Derek , Sá, Michel Pompeu , Sultan, Ibrahim , Strom, Jordan B , Bhatt, Deepak L , Clavel, Marie‐Annick , Sá, Michel Pompeu , Sultan, Ibrahim

Journal of the American Heart Association | May 3, 2024 | Volume: 13 | Issue: 9 | Pages: No page available

10.1161/jaha.123.033872 Get It

Background The mortality risk attributable to moderate aortic stenosis (AS) remains incompletely characterized and has historically been underestimated. We aim to evaluate the association between moderate AS and all‐cause death, comparing it with no/mild AS (in a general referral population and in patients with heart failure with reduced ejection fraction). Methods and Results A systematic review and pooled meta‐analysis of Kaplan–Meier‐derived reconstructed time‐to‐event data of studies published by June 2023 was conducted to evaluate survival outcomes among patients with moderate AS in comparison with individuals with no/mild AS. Ten studies were included, encompassing a total of 409 680 patients (11 527 with moderate AS and 398 153 with no/mild AS). In the overall population, the 15‐year overall survival rate was 23.3% (95% CI, 19.1%–28.3%) in patients with moderate AS and 58.9% (95% CI, 58.1%–59.7%) in patients with no/mild aortic stenosis (hazard ratio [HR], 2.55 [95% CI, 2.46–2.64]; P <0.001). In patients with heart failure with reduced ejection fraction, the 10‐year overall survival rate was 15.5% (95% CI, 10.0%–24.0%) in patients with moderate AS and 37.3% (95% CI, 36.2%–38.5%) in patients with no/mild AS (HR, 1.83 [95% CI, 1.69–2.0]; P <0.001). In both populations (overall and heart failure with reduced ejection fraction), these differences correspond to significant lifetime loss associated with moderate AS during follow‐up (4.4 years, P <0.001; and 1.9 years, P <0.001, respectively). A consistent pattern of elevated mortality rate associated with moderate AS in sensitivity analyses of matched studies was observed. Conclusions Moderate AS was associated with higher risk of death and lifetime loss compared with patients with no/mild AS.
Structural Valve Deterioration After Self-Expanding Transcatheter or Surgical Aortic Valve Implantation in Patients at Intermediate or High Risk
O’Hair, Daniel, Yakubov, Steven J. , Oh, Jae K. , Deeb, G. Michael, Bajwa, Tanvir , Kleiman, Neal S. , Chetcuti, Stanley, Gada, Hemal, Mumtaz, Mubashir , Heiser, John, Merhi, William , Petrossian, George , Robinson, N. Bryce , Tang, Gilbert H.L. , Rovin, Joshua D. , Little, Stephen H. , Jain, Renuka , Verdoliva, Sarah , Hanson, Tim, Li, Shuzhen , Popma, Jeffrey J. , Reardon, Michael J. , Ito, Saki , Reardon, Michael J , Grubb, Kendra J , Deeb, G. Michael , Mieghem, Nicolas M. Van , Adams, David , Søndergaard, Lars , Hanson, Tim

JAMA Cardiology | December 14, 2022 | Volume: 8 | Issue: 2 | Pages: 111

10.1001/jamacardio.2022.4627 Get It

ImportanceThe frequency and clinical importance of structural valve deterioration (SVD) in patients undergoing self-expanding transcatheter aortic valve implantation (TAVI) or surgery is poorly understood.ObjectiveTo evaluate the 5-year incidence, clinical outcomes, and predictors of hemodynamic SVD in patients undergoing self-expanding TAVI or surgery.Design, Setting, and ParticipantsThis post hoc analysis pooled data from the CoreValve US High Risk Pivotal (n = 615) and SURTAVI (n = 1484) randomized clinical trials (RCTs); it was supplemented by the CoreValve Extreme Risk Pivotal trial (n = 485) and CoreValve Continued Access Study (n = 2178). Patients with severe aortic valve stenosis deemed to be at intermediate or increased risk of 30-day surgical mortality were included. Data were collected from December 2010 to June 2016, and data were analyzed from December 2021 to October 2022.InterventionsPatients were randomized to self-expanding TAVI or surgery in the RCTs or underwent self-expanding TAVI for clinical indications in the nonrandomized studies.Main Outcomes and MeasuresThe primary end point was the incidence of SVD through 5 years (from the RCTs). Factors associated with SVD and its association with clinical outcomes were evaluated for the pooled RCT and non-RCT population. SVD was defined as (1) an increase in mean gradient of 10 mm Hg or greater from discharge or at 30 days to last echocardiography with a final mean gradient of 20 mm Hg or greater or (2) new-onset moderate or severe intraprosthetic aortic regurgitation or an increase of 1 grade or more.ResultsOf 4762 included patients, 2605 (54.7%) were male, and the mean (SD) age was 82.1 (7.4) years. A total of 2099 RCT patients, including 1128 who received TAVI and 971 who received surgery, and 2663 non-RCT patients who received TAVI were included. The cumulative incidence of SVD treating death as a competing risk was lower in patients undergoing TAVI than surgery (TAVI, 2.20%; surgery, 4.38%; hazard ratio [HR], 0.46; 95% CI, 0.27-0.78; P = .004). This lower risk was most pronounced in patients with smaller annuli (23 mm diameter or smaller; TAVI, 1.32%; surgery, 5.84%; HR, 0.21; 95% CI, 0.06-0.73; P = .02). SVD was associated with increased 5-year all-cause mortality (HR, 2.03; 95% CI, 1.46-2.82; P &amp;lt; .001), cardiovascular mortality (HR, 1.86; 95% CI, 1.20-2.90; P = .006), and valve disease or worsening heart failure hospitalizations (HR, 2.17; 95% CI, 1.23-3.84; P = .008). Predictors of SVD were developed from multivariate analysis.Conclusions and RelevanceThis study found a lower rate of SVD in patients undergoing self-expanding TAVI vs surgery at 5 years. Doppler echocardiography was a valuable tool to detect SVD, which was associated with worse clinical outcomes.Trial RegistrationClinicalTrials.gov Identifiers: NCT01240902, NCT01586910, and NCT01531374
Abstract 16538: The Impact of Institutional Design on Transcatheter Aortic Valve Replacement Complication Rates in the United States
Pant, Sadip, Golwala, Harsh , Patel, Nilesh, Badheka, Apurva, Deshmukh, Abhishek , Agnihotri, Kanishk, Patel, Nilay, Savani, Chirag, Flaherty, Michael P. , Patel, Samir , Patel, Nilesh, Grubb, Kendra J

Circulation | July 3, 2021 | Volume: 132 | Issue: suppl_3 | Pages: No page available

10.1161/circ.132.suppl_3.16538 Get It

Introduction: With the technical advancements and expanding indications, utilization of TAVR is on the rise among various institutions in the United States .While appropriate patient selection and better techniques are essential to improving outcomes, the impact of institutional design (or hospital setting) on outcomes with TAVR has yet to be examined. Objective: The objective of our study is to compare TAVR complication rates among teaching vs non-teaching centers in the United States Methods: We used Healthcare Cost and Utilization Project - National Inpatient Sample (NIS) data , the largest all payer database of hospital inpatient stay available in United States, to identify patients (age ≥18 years) who underwent TAVR from Jan-Dec 2012. We constructed multivariable models to determine independent predictors (age, sex, race, Charlson’s comorbidity index, hospital size, hospital location and TAVR approach) of TAVR-associated complications. Statistical analysis was performed using Stata IC 11.0 (Stata-Corp, College Station, TX). Results: We identified 7,405 TAVR procedures performed in the United States in 2012. 88% of TAVR were performed in teaching centers. There was no difference in mortality following TAVR between teaching and non-teaching centers. The occurrence of any in-hospital complication was lower in teaching centers as compared to non-teaching centers (42% vs. 50%, p<0.001). Rates of individual complications in teaching vs. non-teaching centers are illustrated in the figure. In adjusted analysis, hemorrhage requiring transfusion (13.2% vs. 20.8%, p<0.001), renal complications requiring dialysis (1.2% vs. 2.3%, p=0.009), respiratory complications (7.5% vs. 11%, p<0.001) and complications requiring open-heart surgery (2% vs. 4.6%, p<0.001) were lower in teaching centers as compared to non-teaching centers. Vascular access site complications, pacemaker insertion, pericardial and neurological complications were similar between teaching and non-teaching centers (Figure). Conclusion: Institutional design impacts TAVR complication rates albeit no difference in mortality. In general, complication rates are lower in teaching centers compared to non-teaching centers.