Back to Authors

Durham, Lucian A.

https://orcid.org/0000-0001-9939-8589

Mayo Clinic

Froedtert Hospital

Citations 3

Clinical Outcomes With Normothermic Pulsatile Organ Perfusion in Heart Transplantation: A Report From the OCS Heart Perfusion Registry
Stehlik, Josef , Farr, Maryjane , Mehra, Mandeep R. , Schroder, Jacob N. , D’Alessandro, David A. , Pal, Jay D. , Villavicencio, Mauricio A. , Gruber, Peter J. , Couper, Gregory S., Shudo, Yasuhiro , Patel, Parag C. , Daneshmand, Mani A. , Klein, Liviu , Shah, Ashish S. , Skipper, Eric, Esmailian, F., Goldstein, Daniel J. , Ohira, Suguru , Kaczorowski, David, Takeda, Koji , Malyala, R., Haft, Jonathan W., Sun, Benjamin , Kilic, Arman , Anyanwu, Anelechi, Williams, Celeste T. , Kai, Masashi , Sulemanjee, Nasir , Funamoto, Masaki , Salerno, Christopher T. , Durham, Lucian A. , Shaffer, Andrew , Zhou, Xiang , Milano, Carmelo A. , Farr, Maryjane A , Goldstein, Daniel , Lozonschi, Lucian , Takeda, Koji , Meyer, Dan M , Sun, Benjamin C , Pretorius, Victor , Pham, Duc T , Kai, Masashi , Sulemanjee, Nasir Z , Funamoto, Masaki , Durham, Lucian A , Shaffer, Andrew , Zafar, Farhan , Pinney, Sean P , Milano, Carmelo A , Mehra, Mandeep R , Lozonschi, Lucian , Pretorius, Victor , Itoh, Akinobu , Ikonomidis, John S.

Circulation | March 7, 2025 | Volume: 151 | Issue: 13 | Pages: 896-909

10.1161/circulationaha.124.071743 Get It

BACKGROUND: A preservation system, the Organ Care System (OCS; TransMedics) uses normothermic pulsatile perfusion during organ transport for heart transplantation. This system has demonstrated favorable outcomes in hearts recovered from extended-criteria donors after brain death (DBD) and donors after circulatory death (DCD). METHODS: The OCS Heart Perfusion Registry collects data on US heart transplantations using the OCS, static cold storage (SCS), or thoracoabdominal normothermic regional perfusion (NRP) and donor hearts recovered from DBD or DCD donors. We analyzed donor and recipient characteristics and posttransplantation outcomes in patients transplanted with OCS donor hearts (either DBD or DCD) compared with SCS hearts, and with OCS hearts from DCD donors compared with those recovered with NRP followed by SCS. Propensity score matching was used in survival analyses to adjust for differences among recipient characteristics. RESULTS: Between 2021 and 2023, 3225 consecutive heart transplantations enrolled from 56 centers were analyzed in the Heart Perfusion Registry. The OCS was used in 854 of 3225 heart transplantations (26.4%), among which 340 (39.8%) were DBD and 514 (60.2%) were DCD donors, whereas 2174 DBD donors were recovered with SCS and another 197 DCD donors with NRP techniques. The OCS-DBD group experienced a greater number of organ offer refusals before final acceptance (13 versus 6; Wilcoxon rank sum, P <0.001) and a longer transport distance (667 miles versus 232 miles; Wilcoxon rank sum, P <0.001) compared with SCS-DBD. Survival at 12 months was similar between the 2 groups (89.9% for OCS-DBD versus 90.6% for SCS-DBD; marginal Cox model, P =0.54). Among the OCS-DCD and SCS-DBD groups, survival at 12 months was also similar (91.0% versus 92.5%, respectively; marginal Cox model, P =0.32). The OCS-DCD and NRP-DCD groups demonstrated similar survival (91.0% versus 91.7%, respectively; log rank, P =0.63), although the transport distance was longer in OCS-DCD compared with DCD with NRP followed by SCS (400 miles versus 223 miles; Wilcoxon rank sum, P <0.001). By 2023, 90% of all OCS donor management and recovery was performed with dedicated organ recovery teams. CONCLUSIONS: We demonstrate that real-world implementation of the OCS for DBD donors (using predominantly a dedicated recovery team) is associated with expanded donor criteria, longer transport distance, and excellent posttransplantation outcomes. In OCS-DCD donors, outcomes parallel those of donors recovered with NRP-DCD and compare favorably with DBD donor organs.
Application of Computer Modeling in Systemic VAD Support of Failing Fontan Physiology
Durham, Lucian A. , Burkhart, Harold M. , Joyce, Lyle D., Cetta, Frank , Phillips, Sabrina D. , Sundareswaran, Kartik S., Farrar, David J. , Park, Soon J., Dearani, Joseph A. , Cabalka, Allison K.

World Journal for Pediatric and Congenital Heart Surgery | April 13, 2011 | Volume: 2 | Issue: 2 | Pages: 243-248

10.1177/2150135110397386 Get It

Although the Fontan procedure has been enormously successful in palliation of single-ventricle patients, many seem to experience progressive failure of the Fontan circulation over time. Ventricular assist devices (VADs) have developed into stable platforms for long-term support of adult patients with heart failure. Given the success of axial flow devices, it was hypothesized that the technology could provide clinical benefit to failing Fontan patients. The aim of this study was to use a computer model to evaluate VAD support in failing Fontan physiology. A computer model of Fontan circulation with heart failure was developed and the HeartMate II (HM II) (Thoratec Corp) axial flow ventricular assist device was connected to this model in a systemic configuration to examine its impact. Cardiac catheterization data from 7 patients (8 catheterization studies) with failing Fontan physiology were applied to this model to evaluate the impact of using the HM II in this manner. When the HM II was used in a systemic configuration at 8000 rpm, there was a 35% decrease in the systemic venous pressure in the Fontan circuit and a 63% decrease in pulmonary capillary wedge pressure with a resultant 41% increase in CI. The model also predicted patient-specific parameters where the VAD may not benefit the patient, such as fixed elevated pulmonary vascular resistance, low systemic ventricular end-diastolic pressure, and high unresponsive systemic vascular resistance. These data suggest a potential benefit from application of axial flow VAD technology in the management of failing Fontan physiology. Clinical correlation will allow for refinement of this model as a predictive tool in discerning which patients may benefit from placement of a VAD and what issues must be addressed prior to implanting the device.
Mitral Annular Growth in Children Following Early Mechanical Mitral Valve Replacement
Durham, Lucian A. , Burkhart, Harold M. , Puga, Francisco J., Dearani, Joseph A. , O’Leary, Patrick , Schaff, Hartzell V.

World Journal for Pediatric and Congenital Heart Surgery | July 20, 2010 | Volume: 1 | Issue: 2 | Pages: 177-181

10.1177/2150135110371487 Get It

Irreparable mitral pathology may lead to early mitral valve replacement (MVR) in children. Often, a small mechanical prosthesis (<23 mm) is required, raising concerns about annular growth in patients who may eventually require subsequent mitral valve re-replacement (MVRR). The aim of this study was to evaluate interval mitral annular growth in this cohort. Between January 1972 and December 2006, 164 children underwent MVR with a mechanical prosthesis; 110 of these children (median age, 4 years; range, 7 days to 14 years) received a small mechanical prosthesis (<23 mm). The most common diagnoses were congenital mitral stenosis (10%), regurgitation (46%), and left atrioventricular valve dysfunction after previous atrioventricular septal defect repair (44%). The cohort was analyzed for age, body surface area (BSA), prosthesis size, and Z score at the time of MVR and MVRR. At the time of MVR, 78 patients had a BSA of 0.77 ± 0.06 m2, had an annular size of 24 ± 0.62 mm ( Z score, 2.91 ± 0.23), and ultimately did not require MVRR. Another cohort, who eventually did require MVRR (n = 24), had an initial BSA at the time of MVR of 0.62 ± 0.05 m2 ( P = NS vs MVR only) and an annular size of 20 ± 0.49 mm ( Z score, 1.85 ± 0.22) ( P = .008 vs MVR only). In the interval between MVR and MVRR (7.8 ± 1.1 years), BSA increased to 1.12 ± 0.07 m2, and annulus size increased to 24 ± 0.47 mm ( Z score, 1.80 ± 0.28). These data suggest growth of the mitral annulus following MVR with a small mechanical prosthesis, as evidenced by an unchanged Z score in the setting of normal interval increase in BSA. Additionally, there was a statistically significant difference in initial Z scores between the cohorts requiring MVRR and those who have not needed re-replacement, suggesting that the feasibility of placement of a slightly larger prosthesis may be associated with a decreased need for MVRR.