Back to Authors

Schroder, Jacob N.

https://orcid.org/0000-0001-5836-7284

Mayo Clinic

Duke University Hospital

Citations 7

Clinical Outcomes With Normothermic Pulsatile Organ Perfusion in Heart Transplantation: A Report From the OCS Heart Perfusion Registry
Stehlik, Josef , Farr, Maryjane , Mehra, Mandeep R. , Schroder, Jacob N. , D’Alessandro, David A. , Pal, Jay D. , Villavicencio, Mauricio A. , Gruber, Peter J. , Couper, Gregory S., Shudo, Yasuhiro , Patel, Parag C. , Daneshmand, Mani A. , Klein, Liviu , Shah, Ashish S. , Skipper, Eric, Esmailian, F., Goldstein, Daniel J. , Ohira, Suguru , Kaczorowski, David, Takeda, Koji , Malyala, R., Haft, Jonathan W., Sun, Benjamin , Kilic, Arman , Anyanwu, Anelechi, Williams, Celeste T. , Kai, Masashi , Sulemanjee, Nasir , Funamoto, Masaki , Salerno, Christopher T. , Durham, Lucian A. , Shaffer, Andrew , Zhou, Xiang , Milano, Carmelo A. , Farr, Maryjane A , Goldstein, Daniel , Lozonschi, Lucian , Takeda, Koji , Meyer, Dan M , Sun, Benjamin C , Pretorius, Victor , Pham, Duc T , Kai, Masashi , Sulemanjee, Nasir Z , Funamoto, Masaki , Durham, Lucian A , Shaffer, Andrew , Zafar, Farhan , Pinney, Sean P , Milano, Carmelo A , Mehra, Mandeep R , Lozonschi, Lucian , Pretorius, Victor , Itoh, Akinobu , Ikonomidis, John S.

Circulation | March 7, 2025 | Volume: 151 | Issue: 13 | Pages: 896-909

10.1161/circulationaha.124.071743 Get It

BACKGROUND: A preservation system, the Organ Care System (OCS; TransMedics) uses normothermic pulsatile perfusion during organ transport for heart transplantation. This system has demonstrated favorable outcomes in hearts recovered from extended-criteria donors after brain death (DBD) and donors after circulatory death (DCD). METHODS: The OCS Heart Perfusion Registry collects data on US heart transplantations using the OCS, static cold storage (SCS), or thoracoabdominal normothermic regional perfusion (NRP) and donor hearts recovered from DBD or DCD donors. We analyzed donor and recipient characteristics and posttransplantation outcomes in patients transplanted with OCS donor hearts (either DBD or DCD) compared with SCS hearts, and with OCS hearts from DCD donors compared with those recovered with NRP followed by SCS. Propensity score matching was used in survival analyses to adjust for differences among recipient characteristics. RESULTS: Between 2021 and 2023, 3225 consecutive heart transplantations enrolled from 56 centers were analyzed in the Heart Perfusion Registry. The OCS was used in 854 of 3225 heart transplantations (26.4%), among which 340 (39.8%) were DBD and 514 (60.2%) were DCD donors, whereas 2174 DBD donors were recovered with SCS and another 197 DCD donors with NRP techniques. The OCS-DBD group experienced a greater number of organ offer refusals before final acceptance (13 versus 6; Wilcoxon rank sum, P <0.001) and a longer transport distance (667 miles versus 232 miles; Wilcoxon rank sum, P <0.001) compared with SCS-DBD. Survival at 12 months was similar between the 2 groups (89.9% for OCS-DBD versus 90.6% for SCS-DBD; marginal Cox model, P =0.54). Among the OCS-DCD and SCS-DBD groups, survival at 12 months was also similar (91.0% versus 92.5%, respectively; marginal Cox model, P =0.32). The OCS-DCD and NRP-DCD groups demonstrated similar survival (91.0% versus 91.7%, respectively; log rank, P =0.63), although the transport distance was longer in OCS-DCD compared with DCD with NRP followed by SCS (400 miles versus 223 miles; Wilcoxon rank sum, P <0.001). By 2023, 90% of all OCS donor management and recovery was performed with dedicated organ recovery teams. CONCLUSIONS: We demonstrate that real-world implementation of the OCS for DBD donors (using predominantly a dedicated recovery team) is associated with expanded donor criteria, longer transport distance, and excellent posttransplantation outcomes. In OCS-DCD donors, outcomes parallel those of donors recovered with NRP-DCD and compare favorably with DBD donor organs.
Long‐term predictors of morbidity and mortality in patients following LVAD replacement
Contreras, Fabian Jimenez , Rames, Jess D. , Schroder, Jacob N. , Katz, Jason N. , Omer, Tariq, Barac, Yaron D. , Milano, Carmelo A. , Jimenez Contreras, Fabian , Rames, Jess David, Barac, Yaron D , Russell, Stuart D. , Omer, Tariq M

Artificial Organs | October 10, 2023 | Volume: 48 | Issue: 2 | Pages: 157-165

10.1111/aor.14651 Get It

AbstractBackgroundAs heart transplant guidelines evolve, the clinical indication for 73% of durable left ventricular assist device (LVAD) implants is now destination therapy. Although completely magnetically levitated LVAD devices have demonstrated improved durability relative to previous models, LVAD replacement procedures are still required for a variety of indications. Thus, the population of patients with a replaced LVAD is growing. There is a paucity of data regarding the outcomes and risk factors for those patients receiving first‐time LVAD replacements.MethodsThe study cohort consisted of all consecutive patients between 2006 and 2020 that received a first‐time LVAD replacement at a single institution. Preoperative clinical and laboratory variables were collected retrospectively. The primary endpoint was death or need for an additional LVAD replacement. Data were subjected to Kaplan–Meier, univariate, and multivariate Cox hazard ratio analyses.ResultsIn total, 152 patients were included in the study, of which 101 experienced the primary endpoint. On multivariate analysis, patients receiving HeartMate 3 (HM3) LVADs as the replacement device showed superior outcomes (HR 0.15, 95% CI 0.065–0.35, p < 0.0001). Independent risk factors for death or need for additional replacement included preoperative extracorporeal membrane oxygenation (ECMO) (HR 4.44, 95% CI 1.87–14.45, and p = 0.00042), increased number of sternotomies (HR 5.20, 95% CI 1.87–14.45, and p = 0.0016), and preoperative mechanical ventilation (HR 1.98, 95% CI 1.01–3.86, and p = 0.045).ConclusionsReplacement with HM3 showed superior outcomes compared to all other pump types when controlling for both initial pump type and other independent predictors of death or LVAD replacement. Preoperative ECMO, mechanical ventilation, and multiple sternotomies also increased the odds for death or the need for subsequent replacement.
A Paradigm Shift in Heart Preservation: Improved Post-transplant Outcomes in Recipients of Donor Hearts Preserved With the SherpaPak System
Shudo, Yasuhiro , Leacche, Marzia , Copeland, Hannah , Molina, Ezequiel , Schroder, Jacob N. , Sciortino, Christopher M., Kawabori, Masashi , D’Alessandro, David A. , Pham, Si M. , Silvestry, Scott , Jacobs, Jeffrey P. , Meyer, Dan M , Zuckermann, Andreas Oliver

ASAIO Journal | September 6, 2023 | Volume: 69 | Issue: 11 | Pages: 993-1000

10.1097/mat.0000000000002036 Get It

Traditional ice storage has been the historic standard for preserving donor’s hearts. However, this approach provides variability in cooling, increasing risks of freezing injury. To date, no preservation technology has been reported to improve survival after transplantation. The Paragonix SherpaPak Cardiac Transport System (SCTS) is a controlled hypothermic technology clinically used since 2018. Real-world evidence on clinical benefits of SCTS compared to conventional ice cold storage (ICS) was evaluated. Between October 2015 and January 2022, 569 US adults receiving donor hearts preserved and transported either in SCTS (n = 255) or ICS (n = 314) were analyzed from the Global Utilization And Registry Database for Improved heArt preservatioN (GUARDIAN-Heart) registry. Propensity matching and a subgroup analysis of >240 minutes ischemic time were performed to evaluate comparative outcomes. Overall, the SCTS cohort had significantly lower rates of severe primary graft dysfunction (PGD) ( p = 0.03). When propensity matched, SCTS had improving 1-year survival ( p = 0.10), significantly lower rates of severe PGD ( p = 0.011), and lower overall post-transplant MCS utilization ( p = 0.098). For patients with ischemic times >4 hours, the SCTS cohort had reduced post-transplant MCS utilization ( p = 0.01), reduced incidence of severe PGD ( p = 0.005), and improved 30-day survival ( p = 0.02). A multivariate analysis of independent risk factors revealed that compared to SCTS, use of ice results in a 3.4-fold greater chance of severe PGD ( p = 0.014). Utilization of SCTS is associated with a trend toward increased post-transplant survival and significantly lower severe PGD and MCS utilization. These findings fundamentally challenge the decades-long status quo of transporting donor hearts using ice.
CARC21: Outcomes in Transplant Recipients Bridged with Impella Support: A GUARDIAN-Heart Subgroup Analysis
Kawabori, Masashi , Kapur, Navin K. , Schroder, Jacob N. , D’Alessandro, David A. , Meyer, Dan M , Pham, Si M.

ASAIO Journal | June 12, 2023 | Volume: 69 | Issue: Supplement 2 | Pages: 53-53

10.1097/01.mat.0000943520.69870.6e Get It

P57: Long Term Predictors of Morbidity and Mortality in Patients Following LVAD Replacement
Rames, Jess D. , Schroder, Jacob N. , Katz, Jason N. , Omer, Tariq, Milano, Carmelo A. , Contreras, Fabian Jimenez , Russell, Stuart D. , Omer, Tariq M , Barac, Yaron D.

ASAIO Journal | June 12, 2023 | Volume: 69 | Issue: Supplement 2 | Pages: 138-138

10.1097/01.mat.0000944048.50509.97 Get It

Multicenter Registry Using Propensity Score Analysis to Compare a Novel Transport/Preservation System to Traditional Means on Postoperative Hospital Outcomes and Costs for Heart Transplant Patients
Leacche, Marzia , Copeland, Hannah , Shudo, Yasuhiro , Molina, Ezequiel J., Stukov, Yuriy , Philpott, Jonathan M. , Kawabori, Masashi , Schroder, Jacob N. , D’Alessandro, David, Molina, Ezequiel , Pham, Si M. , Voigt, Jeffrey , Wolfe, Stanley B. , Jacobs, Jeffrey P. , Meyer, Dan M , Silvestry, Scott

ASAIO Journal | November 18, 2022 | Volume: 69 | Issue: 4 | Pages: 345-349

10.1097/mat.0000000000001844 Get It

The standard method for cardiac allograft preservation for the past 50 years has been static storage using crushed ice. A heart transplant transportation system designed to improve preservation quality with temperature monitoring, the Paragonix SherpaPak Cardiac Transport System (SCTS), was evaluated for its impact on postoperative costs relative to conventional ice storage. Observational US multicenter registry data collected during the August 2015 to November 2021 timeframe from 12 transplant hospitals were analyzed using logistic regression analysis and propensity matching to balance measured baseline covariates and to reduce selection bias. Hospital cost and outcome data post-transplant were then evaluated using various statistical methods. One hundred seventy-four (174) patients were identified resulting in 87 matches. Baseline characteristics were similar between groups. The SCTS group had a significantly lower proportion of ICU days on post-transplant mechanical circulatory support ( p < 0.0001); significantly fewer patients on extracorporeal membrane oxygenation ( p = 0.017); and significantly fewer patients experiencing severe primary graft dysfunction (PGD) ( p = 0.03). Overall hospital plus mechanical circulatory support post-transplant costs were significantly lower by $26.7K in the CTS cohort ( p = 0.03). Use of the SCTS is associated with improved clinical outcomes resulting in significantly lower overall hospital care costs.